| Item No. | Description | Points Deducted |
| 08 | PW filling hoses, caps, connections, procedures; Sample records, valves; PW system constructed, maintained | 0 |
| 10 | Swimming pools / spas maintained, safety equipment | 0 |
| 17 | Temperature practices storage, preparation display, service, transportation; Thawing | 0 |
| 20 | PHF temperature maintenance facilities; Food-contact surfaces designed, constructed, installed, maintained; TMD=s provided, located, calibrated | 0 |
| 21 | Nonfood-contact surfaces designed, constructed, maintained, installed, located | 0 |
| 22 | Dishwashing / equipment washing facilities designed, constructed, maintained, installed, located, operated, TMDs, test kits | 0 |
| 27 | Equipment / utensils non-food-contact surfaces clean | 0 |
| 33 | Decks / bulkheads / deckheads construction, repair, clean | 0 |
|
|
Selected Item Details
|
|
Item No.:
08
|
|
|
Site:
Buffet-Crew and Staff Officer's Messes |
|
Violation:
There were no backflow prevention devices on the supply lines for the coffee machines. |
|
Recommendation:Ensure that a continuous pressure-type backflow preventer is installed when a valve is located downstream from the backflow preventer. |
|
|
Site:
Galley-Soup Station |
|
Violation:
There was a non-continuous backflow prevention device on combination oven #065104. A hose with a spray gun was located downstream of the backflow prevention device. |
|
Recommendation:Ensure that a continuous pressure-type backflow preventer is installed when a valve is located downstream from the backflow preventer. |
|
|
Site:
Other-Main Laundry |
|
Violation:
Three non-continuous backflow prevention devices were installed on the potable water line supplying the detergent dispensing units. A valve was located downstream from these devices. |
|
Recommendation:Ensure that a continuous pressure-type backflow preventer is installed when a valve is located downstream from the backflow preventer. |
|
|
Site:
Whirlpool/Spa-Garden Villa |
|
Violation:
The two showers located in the Garden Villa did not appear to be protected with any form of backflow protection. The hose from the shower could reach below the flood level rim of the shower. |
|
Recommendation:Ensure that backflow preventers are installed when air gaps are impractical or when water under pressure is required. |
|
|