Cruise Ship Inspection Details

  Basic Search |  Advanced Search |  Ship Scored 100 |  Green Sheet
 
Cruise Ship: Norwegian Jewel Cruise line: Norwegian Cruise Lines Inspection Date: 09/30/2009 Score: 100
 
This cruise ship inspection report lists the deficiencies found during the inspection. Additional information corresponding to each item number is available in the lastest editions of the CDC VSP Operational Manual.



 
Cruise Ship's Corrective Action Statement  |  View/Print Summary Report  |  View/Print Detail Report
 
 
Note: Click on the Item no. to view the item detail.
 
Item No.DescriptionPoints Deducted
08PW filling hoses, caps, connections, procedures; Sample records, valves; PW system constructed, maintained0
10Swimming pools / spas maintained, safety equipment0
17Temperature practices storage, preparation display, service, transportation; Thawing0
20PHF temperature maintenance facilities; Food-contact surfaces designed, constructed, installed, maintained; TMD=s provided, located, calibrated0
21Nonfood-contact surfaces designed, constructed, maintained, installed, located0
22Dishwashing / equipment washing facilities designed, constructed, maintained, installed, located, operated, TMDs, test kits0
27Equipment / utensils non-food-contact surfaces clean0
33Decks / bulkheads / deckheads construction, repair, clean0
Selected Item Details
Item No.: 08
Site: Buffet-Crew and Staff Officer's Messes
Violation: There were no backflow prevention devices on the supply lines for the coffee machines.
Recommendation:Ensure that a continuous pressure-type backflow preventer is installed when a valve is located downstream from the backflow preventer.
Site: Galley-Soup Station
Violation: There was a non-continuous backflow prevention device on combination oven #065104. A hose with a spray gun was located downstream of the backflow prevention device.
Recommendation:Ensure that a continuous pressure-type backflow preventer is installed when a valve is located downstream from the backflow preventer.
Site: Other-Main Laundry
Violation: Three non-continuous backflow prevention devices were installed on the potable water line supplying the detergent dispensing units. A valve was located downstream from these devices.
Recommendation:Ensure that a continuous pressure-type backflow preventer is installed when a valve is located downstream from the backflow preventer.
Site: Whirlpool/Spa-Garden Villa
Violation: The two showers located in the Garden Villa did not appear to be protected with any form of backflow protection. The hose from the shower could reach below the flood level rim of the shower.
Recommendation:Ensure that backflow preventers are installed when air gaps are impractical or when water under pressure is required.
*Inspections scores of 85 or lower are NOT satisfactory