Serum transferrin receptor and ferritin were measured in pregnant women from NHANES 1999-2000 to provide estimates of iron deficiency based on body iron levels observed in these women. Body iron estimates can be predicted using an equation that includes measured serum transferrin receptor and serum ferritin levels. Serum transferrin receptor was not added to NHANES until 2003. Serum ferritin was measured in NHANES 1999-2000 with a method that has now been shown to differ from the method needed to provide the appropriate ferritin values for use in the body iron model equation. Thus, serum ferritin was re-measured using the appropriate method for body iron calculations.
Pregnant women aged 13 to 56 years from NHANES 1999-2000 with stored sera (N = 625). The pregnant women for this sample were identified using either one of the two available summary pregnancy variables (RIDEXPRG or RIDPREG) or in the case of 20 women < 18 years of age from NHANES 1999-2000, with the self-reported pregnancy item RHQ140. This item was used for these 20 women because RIDEXPRG and RIDPREG were not provided for women < 18 years of age in NHANES 1999-2000.
The method for measurement of soluble transferrin receptor (sTfR) is immuno-turbidimetry using Roche kits on the Hitachi 912 clinical analyzer. Latex bound anti-sTfR antibodies react with the antigen in the sample to form an antigen/antibody complex. Following agglutination, this is measured turbidimetrically. This is the same method used to measures sTfR starting in NHANES 2003+.
The method principle for measurement of Ferritin is immuno-turbidimetry using the Roche/Hitachi 912 clinical analyzer. Latex bound Ferritin antibodies react with the antigen in the sample to form an antigen/antibody complex. Following agglutination, this is measured turbidimetrically. Complexes formed are proportional to the Ferritin concentration, and were measured at 700nm (primary wavelength). This is the same method used to measure serum ferritin starting in NHANES 2004. These ferritin data do not need to be adjusted to be compared with NHANES 2003-2004 ferritin data.
Data was received after the sTfR and ferritin assays were complete. The data were not edited.
Data Access: All data are publicly available.
The NHANES quality control and quality assurance protocols (QA/QC) meet the 1988 Clinical Laboratory Improvement Amendments mandates. Detailed quality control and quality assurance instructions are discussed in the NHANES Laboratory/Medical Technologists Procedures Manual (LPM). A detailed description of the quality assurance and quality control procedures can be found at NHANES web site.
There are two variables:
SSTFR: serum transferrin receptor (mg/L)
SSFER: Serum ferritin (ng/mL)
Code or Value | Value Description | Count | Cumulative | Skip to Item |
---|---|---|---|---|
1.4 to 9 | Range of Values | 248 | 248 | |
. | Missing | 0 | 248 |
Code or Value | Value Description | Count | Cumulative | Skip to Item |
---|---|---|---|---|
4 to 245 | Range of Values | 247 | 247 | |
. | Missing | 1 | 248 |