| Operational Manual Section: : POTABLE WATER |
VSP Requirement
5.3.2.1.1 : Ensure potable water tanks do not share a common wall with the hull of the vessel or with tanks or piping containing nonpotable water or other liquids. |
|
|
|
Summary: Operate with potable water tanks that share a wall with the vessel hull based on the use of salinity sensors, alarms, a monitoring plan and a contingency plan if leaks are detected.
|
|
|
|
|