Variances by: Section
Cruise Ship:   Norwegian Gem 
Cruise Line:   Norwegian Cruise Lines 
 
VSP Operations Manual Section:  6.2.2.2.3


Manual Requirement: Install chart recorders or electronic data loggers with security features that record pH and halogen measurements for each individual RWF. Ensure the sample line for the analyzer probe (monitoring) is either directly from the RWF or on the return line from each RWF and before the compensation tank. Install appropriate sample taps for analyzer calibration. In the event of equipment failure, measure free residual halogen and pH by a manual test kit at the RWF or return line at least hourly for whirlpool spas, spa pools, children?s pools, and wading pools and every 4 hours for all other RWFs. Record manual readings on a chart or log, retain for at least 12 months, and ensure that they are available for review during inspections. Complete repairs on malfunctioning halogen analyzer-chart recorders within 30 days of equipment failure. Provide an audible alarm in a continuously occupied watch station to indicate low and high free halogen and pH readings in each RWF.

Request: Allow one electronic data logger on the return line for the two, one-person whirlpools in both the male and female spas.

Status:  Denied

Summary:Allow one electronic data logger on the return line for the two, one-person whirlpools in both the male and female spas.
 
VSP Operations Manual Section:  6.6.1


Manual Requirement: Drain jetted tubs once per day and clean and disinfect them every 7 days or between occupancies, whatever is more frequent. Disinfect with an appropriate halogen-based disinfectant at 10 ppm for 60 minutes, or an equivalent CT value. Implement one of the following procedures for heated jetted tubs: (1) Drain, clean, and disinfect heated jetted tubs daily. Install a safety sign at the tub entrance advising users that using heated jetted tubs without the use of automated halogen and pH control may increase the risk of respiratory infections. (2) With an approved variance, drain heated jetted tubs every 3 days. Clean and disinfect tubs twice a week or between occupancies, whatever is more frequent. No signage is required.

Request: Operate heated jetted tub, draining every 3 days and disinfecting twice a week or between occupancies.

Status:  Approved

Summary:Operate heated jetted tub, draining every 3 days and disinfecting twice a week or between occupancies.
 