Schedule
|
13F
|
Approval Number
|
0541
|
Manufacturer
|
Biomarine, Inc.
|
Approval Date
|
6/18/2007
|
Product Line
|
BioPak 240R Closed Circuit, 240 minute SCBA
|
For Protection Against
|
|
Service Time (minutes)
|
240
|
Facepiece Type
|
Full Facepiece
|
Is the respirator powered?
|
Non-powered
|
Number of Filters
|
|
Is the the filter replaceable?
|
No
|
Filter Location
|
|
Cartridge or Canister
|
|
Number of cartridge or canisters
|
|
Location of cartridge or canisters
|
|
Is the cartridge or canister replacable?
|
No
|
Self-contained breathing apparatus (SCBA) Type
|
Closed Circuit
|
Supplied air respirator (SAR) Type
|
|
Self-contained breathing apparatus (SCBA) Use
|
Entry and Escape
|
Airflow
|
Pressure Demand
|
Breathing Gas
|
Compressed Oxygen
|
Percentage of Oxygen in Breathing Gas
|
90
|
Regulator Location
|
Back- or backpack-mounted
|
Low Temperature (Celsius)
|
-15
|
Low Temperature (Fahrenheit)
|
5
|
Exhalation Valve?
|
No
|
Self Rescuer?
|
No
|
Is the approval obsolete?
|
No
|
Private Label |
Scott Health and Safety, Monroe, NC - Model BioPak 240R
|
Model
|
|
Rated Duration
|
|
Cylinder pounds per square inch gauge (PSIG)
|
3000 psig
|
Chemical, biological, radiological and nuclear (CBRN) Approval Date
|
|