Approval Details

Schedule 13F
Approval Number 0960CBRN
Manufacturer Interspiro USA, Inc.
Approval Date 10/28/2019
Product Line Model S9 and S9 Incurve, 30 Minute, 2216 PSIG, CBRN Self-Contained Breathing Apparatus
For Protection Against
Service Time (minutes) 30
Facepiece Type Full Facepiece
Is the respirator powered? Non-powered
Number of Filters
Is the the filter replaceable? No
Filter Location
Cartridge or Canister
Number of cartridge or canisters
Location of cartridge or canisters
Is the cartridge or canister replacable? No
Self-contained breathing apparatus (SCBA) Type Open Circuit
Supplied air respirator (SAR) Type
Self-contained breathing apparatus (SCBA) Use Entry and Escape
Airflow Pressure Demand
Breathing Gas Compressed Air
Percentage of Oxygen in Breathing Gas Must meet or exceed CGA Grade D air requirements
Regulator Location Facepiece-mounted
Low Temperature (Celsius) -31.7
Low Temperature (Fahrenheit) -25
Exhalation Valve? Yes
Self Rescuer? No
Is the approval obsolete? No
Private Label
Model S9 and S9 Incurve
Rated Duration 30 Minute
Cylinder pounds per square inch gauge (PSIG) 2216
Chemical, biological, radiological and nuclear (CBRN) Approval Date 10/28/2019
Comments End of Service Time Indicator, EOSTI-33, configuration meets NFPA 1981: 2018 edition