The specific objective of this component is to determine the prevalence of iron deficiency anemia using iron and TIBC (transferrin saturation) in conjunction with ferritin and erythrocyte protoporphyrin. The general objectives of the nutritional biochemistry components are:
These data will be used to estimate deficiencies and toxicities of specific nutrients in the population and subgroups, to provide population reference data, and to estimate the contribution of diet, supplements, and other factors to serum levels of nutrients. Data will be used for research to further define nutrient requirements as well as optimal levels for disease prevention and health promotion.
Participants aged 1 year and older who do not meet any of the exclusion criteria are eligible.
The iron and TIBC tests were performed in two labs for NHANES 2001–2002.
Division of Laboratory Services, NCEH, CDC:
Serum iron and TIBC tests were measured by a modification of the automated AAII-25 colorimetric method, which was based on the procedures of Giovaniello et al. and Ramsey. The method was modified to be performed on an Alpkem Flow Solutions 3000 (rapid-flow analysis) system. Iron was quantitated by measuring the intensity of the violet complex formed in the reaction between ferrozine and Fe++ in acetate buffer and measured at 562 nm. Thiourea was added to complex Cu++, which can also bind with ferrozine and yield falsely elevated iron values. For the TIBC test, serum was mixed with 400 g/dL iron solution to saturate the iron-binding sites of the serum transferrin molecules. Magnesium carbonate was used to remove excess iron. Centrifugation was used to precipitate the magnesium carbonate, and the supernatant was measured for iron content.
Collaborative Laboratory Services
A known ferrous iron standard of 105 μmol/L (586 μg/dL) was incubated with serum at a pH of 7.9, which saturates the available binding sites on serum transferrin. The unbound excess iron was then complexed with ferene to form ferrous ferene, a blue complex, which was measured by the Beckman/Coulter LX 20 analyzer. The UIBC was equal to the total iron added minus the excess iron. The TIBC is the sum of iron and UIBC.
The transferrin saturation value was calculated as (iron/TIBC) × 100%. The iron variable name is LBXIRN, the TIBC variable name is LBXTIB, and the transferrin saturation is LBDPCT.
Specimens were processed, stored, and shipped to Division of Laboratory Sciences, National Center for Environmental Health, Centers for Disease Control and Prevention, Atlanta, Georgia, and to Collaborative Laboratory Services in Ottumwa, Iowa. Detailed specimen collection and processing instructions are discussed in the NHANES LPM. Read the LABDOC file for detailed data processing and editing protocols. The analytical methods are described in detail in the Description of the Laboratory Methodology section.
The NHANES quality control and quality assurance protocols (QA/QC) meet the 1988 Clinical Laboratory Improvement Amendments mandates. Detailed quality control and quality assurance instructions are discussed in the NHANES Laboratory/Medical Technologists Procedures Manual (LPM). Read the LABDOC file for detailed QA/QC protocols.
The Division of Laboratory Sciences, National Center for Environmental Health, Centers for Disease Control and Prevention performed testing in 2001, and Collaborative Laboratory Services at Ottumwa, Iowa performed testing in 2002.
The analysis of NHANES 2001–2002 laboratory data must be conducted with the key survey design and basic demographic variables. The NHANES 2001–2002 Household Questionnaire Data files contain demographic data, health indicators, and other related information collected during household interviews. They also contain all survey design variables and sample weights for these age groups. The phlebotomy file includes auxiliary information such as the conditions precluding venipuncture. The household questionnaire and phlebotomy files may be linked to the laboratory data file using the unique survey participant identifier SEQN.
The LBXIRN is the reference iron method and was used with TIBC to calculate the transferrin saturation (LBXPCT). Do not use the chemistry profile iron (LBXSIR) to calculate the transferrin saturation.
Adjustment of data between the laboratories: The distributions of sample person results were compared between the Division of Laboratory Sciences Lab (2001) and the Collaborative Laboratory Services Lab (2002). The means of the sample person distributions for the two labs were compared using a weighted t test. The mean of iron showed no significant difference (p > 0.05) for the two labs. The TIBC test had significantly (p < 0.05) different means. A cross-over study between the two labs was performed to establish linear regression equations to convert Collaborative Laboratory Services values to the Division of Laboratory Sciences Laboratory values . The regression equations were applied to the TIBC test, and a weighted t test was done after regression. The weighted t test revealed no significant differences (p > 0.05) of TIBC means between the two labs after regression.
Code or Value | Value Description | Count | Cumulative | Skip to Item |
---|---|---|---|---|
3 to 357 | Range of Values | 8814 | 8814 | |
. | Missing | 1115 | 9929 |
Code or Value | Value Description | Count | Cumulative | Skip to Item |
---|---|---|---|---|
0.54 to 63.90 | Range of Values | 8814 | 8814 | |
. | Missing | 1115 | 9929 |
Code or Value | Value Description | Count | Cumulative | Skip to Item |
---|---|---|---|---|
33 to 765 | Range of Values | 8762 | 8762 | |
. | Missing | 1167 | 9929 |
Code or Value | Value Description | Count | Cumulative | Skip to Item |
---|---|---|---|---|
5.91 to 136.94 | Range of Values | 8762 | 8762 | |
. | Missing | 1167 | 9929 |
Code or Value | Value Description | Count | Cumulative | Skip to Item |
---|---|---|---|---|
0.5 to 124.2 | Range of Values | 8759 | 8759 | |
. | Missing | 1170 | 9929 |