The specific aims of the component are:
The tobacco component for NHANES will include questionnaire items on current and past use of cigarettes, pipes, cigars and smokeless tobacco. Exposure to ETS at home and at work and in-utero ETS exposure among children will also be obtained. ETS exposure will also be assessed for examinees 3 years of age and older through the measurement of serum cotinine, a metabolite of nicotine. In addition, use of nicotine replacement products (e.g., gum and patch) will be collected using questionnaires.
Participants aged 3 years and older who do not meet any of the exclusion criteria are eligible.
Cotinine is a major metabolite of nicotine that may be used as a marker for both active smoking, and as an index to Environmental Tobacco Smoke (ETS) exposure, or "passive smoking". Cotinine is generally preferred over nicotine for such assessments because of its substantially longer half-life. The half-life of cotinine in plasma has been estimated to be about 15–20 hrs;1–3 by contrast, the half-life of nicotine is only 0.5–3 hrs.4-6 Cotinine may be measured in serum, urine or saliva – the half-life of cotinine in all three fluids is essentially the same. Cotinine concentrations tend to be higher (3–8×) in urine than in serum; however, for studies requiring a quantitative assessment of exposure, plasma or serum is regarded as the fluid of choice.1 Therefore, serum was chosen for NHANES cotinine analyses.
Serum cotinine is measured by an isotope dilution-high performance liquid chromatography / atmospheric pressure chemical ionization tandem mass spectrometry (ID HPLC-APCI MS/MS). Briefly, the serum sample is spiked with methyl-D3 cotinine as an internal standard, and after an equilibration period, the sample is applied to a basified solid-phase extraction column. Cotinine is extracted off the column with methylene chloride, the organic extract is concentrated, and the residue is injected onto a short, C18 HPLC column. The eluant from these injections is monitored by APCI-MS/MS, and the m/z 80 daughter ion from the m/z 177 quasi-molecular ion is quantitated, along with additional ions for the internal standard, external standard, and for confirmation. Cotinine concentrations are derived from the ratio of native to labeled cotinine in the sample by comparisons to a standard curve.
There were no changes to the equipment or lab site from the previous 2 years.
Serum specimens are processed, stored, and shipped to the Division of Environmental Health Laboratory Sciences, National Center for Environmental Health, Centers for Disease Control and Prevention for analysis.
Detailed specimen collection and processing instructions are discussed in the NHANES LPM. Vials are stored under appropriate frozen (–20°C) conditions until they are shipped to National Center for Environmental Health for testing.
This file contains no top coding.
The detection limits in each two year cycle from 1999 to 2004 has changed. For 1999-2000 the detection limit was .05 and the below the limit of detection value was .035.
For 2001-2002 there were two detection limits and below the limit of detection values. One of the detection limits was .05 and the below the limit of detection value was .035. The other detection limit was .015 and the below the limit of detection value was .011.
For 2003-2004 the detection limit was .015 and the below the limit of detection value was .011.
Detailed instructions on specimen collection and processing can be found on the NHANES website.
The NHANES quality assurance and quality control (QA/QC) protocols meet the 1988 Clinical Laboratory Improvement Amendments mandates. Detailed QA/QC instructions are discussed in the NHANES Laboratory/Medical Technologists Procedures Manual (LPM). Read the LABDOC file for detailed QA/QC protocols.
A detailed description of the quality assurance and quality control procedures can be found on the NHANES website.
The analysis of NHANES 2003–2004 laboratory data must be conducted with the key survey design and basic demographic variables. The NHANES 2003–2004 Household Questionnaire Data Files contain demographic data, health indicators, and other related information collected during household interviews. The Household Questionnaire Data Files also contain all survey design variables and sample weights required to analyze these data. The Phlebotomy Examination file includes auxiliary information on duration of fasting, the time of day of the venipuncture, and the conditions precluding venipuncture. The Household Questionnaire and Phlebotomy Exam files may be linked to the laboratory data file using the unique survey participant identifier SEQN.
Code or Value | Value Description | Count | Cumulative | Skip to Item |
---|---|---|---|---|
0.015 to 1639 | Range of Values | 6478 | 6478 | |
0.011 | Below Limit of Detection | 1314 | 7792 | |
. | Missing | 764 | 8556 |