Table of Contents

Component Description

Mumps IgG antibody testing of stored serum specimens from NHANES (1999-2000) was conducted to estimate the seroprevalence of mumps antibody in the US population in 1999-2000.

Eligible Sample

Participants aged 6-49 years from of NHANES 1999-2000 with stored sera.

Description of Laboratory Methodology

Mumps antibody testing was performed using enzyme-linked immunosorbent assays (ELISAs) to detect mumps IgG (Wampole Laboratories, Princeton, NJ).

Specimens were tested according to manufacture directions.

Index values were calculated for each specimen by dividing the OD value by the cutoff OD.

Interpretation of Index Value of OD Ratio
Interpretation Index Value of OD Ratio 
Negative Specimens ≤0.900
Equivocal Specimens 0.901-1.099
Positive Specimens ≥1.100

Data Processing and Editing

Data Access: All data are publicly available.

Laboratory Quality Assurance and Monitoring

Serum samples were tested using Wampole Mumps IgG Test (Ref. # 425901CE). These were tested on two lots, the first lot used 19 kits and second lot used 57 kits.

Samples that initially tested Indeterminate or negative were repeated. If a discrepancy (difference in result and a change in ISR of > 0.5) was found the sample was repeated one more time. The previous result that matched the final test was the one accepted.

Assay reproducibility was assessed by random selection of 10% of the total number of serum specimens tested and repeating the ELISA assay.

Analytic Notes

The specimen index ratio (ISR) should be linked to the sequence number for all data analyses.

Subsample Weights

Sample weights are required to analyze these data properly. Specific sample weights for this subsample are included in this data file and should be used when analyzing these data. When observations were removed from this data file,  new sample weight were created and  added to this data file (WTSSMC2Y, WTSSMC4Y). Please refer to the NHANES Analytic Guidelines and the on-line NHANES Tutorial for further details on the use of sample weights and other analytic issues.

Codebook and Frequencies

SEQN - Respondent sequence number

Variable Name:
SEQN
SAS Label:
Respondent sequence number
English Text:
Respondent sequence number.
Target:
Both males and females 6 YEARS - 49 YEARS

WTSSMC2Y - SSMUMP and SSCMV 2 year weights

Variable Name:
WTSSMC2Y
SAS Label:
SSMUMP and SSCMV 2 year weights
English Text:
Surplus specimen SSMUMP and SSCMV 2 year weights
Target:
Both males and females 6 YEARS - 49 YEARS
Code or Value Value Description Count Cumulative Skip to Item
1250.36054 to 298307.64146 Range of Values 4136 4136
0 No lab specimen 3 4139
. Missing 0 4139

WTSSMC4Y - SSMUMP and SSCMV 4 year weights 99-02

Variable Name:
WTSSMC4Y
SAS Label:
SSMUMP and SSCMV 4 year weights 99-02
English Text:
Surplus specimen SSMUMP and SSCMV 4 year weights 99-02
Target:
Both males and females 6 YEARS - 49 YEARS
Code or Value Value Description Count Cumulative Skip to Item
769.842844 to 119080.51994 Range of Values 4136 4136
0 No lab specimen 3 4139
. Missing 0 4139

SSISR - Specimen Index ratio

Variable Name:
SSISR
SAS Label:
Specimen Index ratio
English Text:
Specimen Index ratio
Target:
Both males and females 6 YEARS - 49 YEARS
Code or Value Value Description Count Cumulative Skip to Item
0.026 to 8.604 Range of Values 4132 4132
. Missing 7 4139

SSMUMPS - Antibody to mumps

Variable Name:
SSMUMPS
SAS Label:
Antibody to mumps
English Text:
Antibody to mumps
Target:
Both males and females 6 YEARS - 49 YEARS
Code or Value Value Description Count Cumulative Skip to Item
1 Positive 3770 3770
2 Negative 212 3982
3 Indeterminate 150 4132
9 Quantity not sufficient 0 4132
. Missing 7 4139