Urinary Polyaromatic Hydrocarbons (PAHs)
PAHs constitute a group of chemicals which are formed during the incomplete combustion of coal, oil and gas, garbage, and other organic substances. In general, people are exposed to mixtures of PAHs, and the sources are widespread, including vehicle exhausts, asphalt, coal tar, wild fires, agricultural burning, charbroiled foods, and tobacco smoke. PAHs enter the body quickly and easily by all routes of exposure and are readily and predominantly metabolized to hydroxylated metabolites and glucuronide metabolites. These compounds require metabolic activation in order to interact with cellular macromolecules. Measurement of urinary metabolites indicates exposure to the parent PAHs. Although background ranges of PAHs in air and water are known, less is known about PAH background levels in humans.
Participants, aged 6 years and older, from a one-third sample were eligible.
The specific analytes measured in this method are monohydroxylated metabolites of PAHs (OH-PAHs). This procedure involves enzymatic hydrolysis of glucuronidated/sulfated OH-PAH metabolites in urine, extraction, derivatization, and analysis using isotope dilution capillary gas chromatography tandem mass spectrometry (GC-MS/MS). Ion transitions specific to each analyte and carbon-13 labeled internal standards are monitored, and the abundances of each ion are measured.
There were no changes to the lab method, lab equipment, or lab site for this component in the NHANES 2009-2010 cycle.
Refer to the Lab Method File for Monohydroxy Polycyclic Aromatic Hydrocarbons.
POLYAROMATIC_HYDROCARBONS_ URINE (August 2015)
Urine specimens are processed, stored, and shipped to the Division of Laboratory Sciences, National Center for Environmental Health, Centers for Disease Control and Prevention, Atlanta, GA for analysis.
Detailed instructions on specimen collection and processing are discussed in the NHANES Laboratory Procedures Manual (LPM). Vials are stored under appropriate frozen (–30°C) conditions until they are shipped to National Center for Environmental Health for testing.
Vials are stored under appropriate frozen (–20°C) conditions until they are shipped to National Center for Environmental Health for testing.
Mobile Examination Centers (MECs)
Laboratory team performance is monitored using several techniques. NCHS and contract consultants use a structured quality assurance evaluation during unscheduled visits to evaluate both the quality of the laboratory work and the quality-control procedures. Each laboratory staff person is observed for equipment operation, specimen collection and preparation; testing procedures and constructive feedback are given to each staff. Formal retraining sessions are conducted annually to ensure that required skill levels were maintained.
The NHANES QA/QC protocols meet the 1988 Clinical Laboratory Improvement Act mandates. Detailed QA/QC instructions are discussed in the NHANES LPM.
Analytical Laboratories
NHANES uses several methods to monitor the quality of the analyses performed by the laboratories. In the MEC, these methods include performing blind split samples collected on “dry run” sessions. In addition, contract laboratories randomly perform repeat testing on 2% of all specimens.
NCHS developed and distributed a quality control protocol for all the contract laboratories which outlined the use of Westgard rules (Westgard, et al. 1981) when running NHANES specimens. Progress reports containing any problems encountered during shipping or receipt of specimens, summary statistics for each control pool, QC graphs, instrument calibration, reagents, and any special considerations are submitted to NCHS quarterly. The reports are reviewed for trends or shifts in the data. The laboratories are required to explain any identified areas of concern.
All QC procedures recommended by the manufacturers were followed. Reported results for all assays meet the Division of Laboratory Science’s quality control and quality assurance performance criteria for accuracy and precision, similar to the Westgard rules (Caudill, et al., 2008).
The data were reviewed. Incomplete data or improbable values were sent to the performing laboratory for confirmation.
Refer to the 2009-2010 Laboratory Data Overview for general information on NHANES laboratory data.
Subsample weights
Measures of urinary PAHs were measured in a one third subsample of persons 6 years and older. Special sample weights are required to analyze these data properly. Specific sample weights for this subsample are included in this data file and should be used when analyzing these data.
Demographic and Other Related Variables
The analysis of NHANES laboratory data must be conducted with the key survey design and basic demographic variables. The NHANES Demographic Data File contains demographic and sample design variables. The recommended procedure for variance estimation requires use of stratum and PSU variables (SDMVSTRA and SDMVPSU, respectively) in the demographic data file. This laboratory data file can be linked to the other NHANES data files using the unique survey participant identifier SEQN.
Detection Limits
The detection limits were constant for all of the analytes in the data set. Two variables are provided for each of these analytes. The variable named URD___LC indicates whether the result was below the limit of detection. There are two values: “0” and “1”. “0” means that the result was at or above the limit of detection. “1” indicates that the result was below the limit of detection. The other variable named URX___ provides the analytic result for that analyte. For analytes with analytic results below the lower limit of detection (i.e., URD___LC=1), an imputed fill value was placed in the analyte results field. This value is the lower limit of detection divided by square root of 2 (LLOD/sqrt(2)).
The lower limit of detection (LLOD, in ng/L) for urinary PAHs is:
Analyte | Item ID | LLOD |
---|---|---|
Urinary 2-Hydroxyfluorene | URXP04 | 10.0 |
Urinary 3-Hydroxyfluorene | URXP03 | 10.0 |
Urinary 9-Hydroxyfluorene | URXP17 | 10.0 |
Urinary 1-Hydroxyphenanthrene | URXP06 | 10.0 |
Urinary 2-Hydroxyphenanthrene | URXP07 | 10.0 |
Urinary 3-Hydroxyphenanthrene | URXP05 | 10.0 |
Urinary 1-Hydroxypyrene | URXP10 | 10.0 |
Urinary 1-Hydroxynapthalene (1-Naphthol) | URXP01 | 44.0 |
Urinary 2-Hydroxynapthalene (2-Naphthol) | URXP02 | 42.0 |
Urinary 4-Hydroxyphenanthrene | URXP19 | 10.0 |
Please refer to the NHANES Analytic Guidelines and the on-line NHANES Tutorial for further details on the use of sample weights and other analytic issues.
Code or Value | Value Description | Count | Cumulative | Skip to Item |
---|---|---|---|---|
0 to 426061.06902 | Range of Values | 2819 | 2819 | |
. | Missing | 0 | 2819 |
Code or Value | Value Description | Count | Cumulative | Skip to Item |
---|---|---|---|---|
55 to 11664396 | Range of Values | 2747 | 2747 | |
. | Missing | 72 | 2819 |
Code or Value | Value Description | Count | Cumulative | Skip to Item |
---|---|---|---|---|
0 | At or above the detection limit | 2747 | 2747 | |
1 | Below lower detection limit | 0 | 2747 | |
. | Missing | 72 | 2819 |
Code or Value | Value Description | Count | Cumulative | Skip to Item |
---|---|---|---|---|
127 to 102128 | Range of Values | 2747 | 2747 | |
. | Missing | 72 | 2819 |
Code or Value | Value Description | Count | Cumulative | Skip to Item |
---|---|---|---|---|
0 | At or above the detection limit | 2747 | 2747 | |
1 | below lower detection limit | 0 | 2747 | |
. | Missing | 72 | 2819 |
Code or Value | Value Description | Count | Cumulative | Skip to Item |
---|---|---|---|---|
7.1 to 5718 | Range of Values | 2744 | 2744 | |
. | Missing | 75 | 2819 |
Code or Value | Value Description | Count | Cumulative | Skip to Item |
---|---|---|---|---|
0 | At or above the detection limit | 2707 | 2707 | |
1 | Below lower detection limit | 37 | 2744 | |
. | Missing | 75 | 2819 |
Code or Value | Value Description | Count | Cumulative | Skip to Item |
---|---|---|---|---|
11 to 14823 | Range of Values | 2747 | 2747 | |
. | Missing | 72 | 2819 |
Code or Value | Value Description | Count | Cumulative | Skip to Item |
---|---|---|---|---|
0 | At or above the detection limit | 2747 | 2747 | |
1 | Below lower detection limit | 0 | 2747 | |
. | Missing | 72 | 2819 |
Code or Value | Value Description | Count | Cumulative | Skip to Item |
---|---|---|---|---|
7.1 to 2314 | Range of Values | 2746 | 2746 | |
. | Missing | 73 | 2819 |
Code or Value | Value Description | Count | Cumulative | Skip to Item |
---|---|---|---|---|
0 | At or above the detection limit | 2705 | 2705 | |
1 | Below lower detection limit | 41 | 2746 | |
. | Missing | 73 | 2819 |
Code or Value | Value Description | Count | Cumulative | Skip to Item |
---|---|---|---|---|
7.1 to 5864 | Range of Values | 2746 | 2746 | |
. | Missing | 73 | 2819 |
Code or Value | Value Description | Count | Cumulative | Skip to Item |
---|---|---|---|---|
0 | At or above the detection limit | 2740 | 2740 | |
1 | Below lower detection limit | 6 | 2746 | |
. | Missing | 73 | 2819 |
Code or Value | Value Description | Count | Cumulative | Skip to Item |
---|---|---|---|---|
7.1 to 2646 | Range of Values | 2744 | 2744 | |
. | Missing | 75 | 2819 |
Code or Value | Value Description | Count | Cumulative | Skip to Item |
---|---|---|---|---|
0 | At or above the detection limit | 2710 | 2710 | |
1 | Below lower detection limit | 34 | 2744 | |
. | Missing | 75 | 2819 |
Code or Value | Value Description | Count | Cumulative | Skip to Item |
---|---|---|---|---|
7.1 to 8523 | Range of Values | 2746 | 2746 | |
. | Missing | 73 | 2819 |
Code or Value | Value Description | Count | Cumulative | Skip to Item |
---|---|---|---|---|
0 | At or above the detection limit | 2729 | 2729 | |
1 | Below lower detection limit | 17 | 2746 | |
. | Missing | 73 | 2819 |
Code or Value | Value Description | Count | Cumulative | Skip to Item |
---|---|---|---|---|
7.1 to 50872 | Range of Values | 2747 | 2747 | |
. | Missing | 72 | 2819 |
Code or Value | Value Description | Count | Cumulative | Skip to Item |
---|---|---|---|---|
0 | At or above the detection limit | 2746 | 2746 | |
1 | Below lower detection limit | 1 | 2747 | |
. | Missing | 72 | 2819 |
Code or Value | Value Description | Count | Cumulative | Skip to Item |
---|---|---|---|---|
4 to 749 | Range of Values | 2757 | 2757 | |
. | Missing | 62 | 2819 |