Table of Contents

Component Description

Volatile Organic Compounds (Whole Blood) - Trihalomethanes/MTBE/Nitromethane

Volatile organic compounds (VOCs) are a large group of chemicals that have been used as solvents, degreasers, and cleaning agents in industry and consumer products. Many of the VOCs were found to contaminate ground water and drinking water sources. Because of human health concerns, these VOCs have been banned or restricted from most uses.

The prevalence of disinfection by-products in drinking water supplies has raised concerns about possible adverse health effects from chronic exposure to these potentially carcinogenic compounds. Methyl-tert-butyl ether (MTBE) was used as an additive to replace lead in gasoline, but its use was banned after widespread ground water contamination was discovered.

Inhalation is the most common VOC route of exposure in the general population, including indoor sources such as paints, adhesives, cleaning solutions, and aerosolized insecticide sprays; industries producing these solvents; and contaminated waste disposal sites. Drinking water may contribute to exposure when underground drinking water supplies are contaminated. After they are absorbed in the body, VOCs are rapidly eliminated in exhaled breath, or may be rapidly metabolized and eliminated in the urine.

Eligible Sample

Examined participants aged 12 years and older from a one-half sample were eligible.

Description of Laboratory Methodology

Trihalomethanes (THMs), nitromethane (NM: biomarker for halonitromethanes), and methyl tert-butyl ether (MTBE) are measured in whole blood by solid phase microextraction/gas chromatography/isotope dilution mass spectrometry (SPME/GC/isotope dilution MS) based on the method described by Bonin, et al. The method is applicable to the determination of five VOCs in 3-mL samples of whole blood with detection limits in the low parts per trillion (pptr) range. Since non-occupationally exposed individuals have blood VOC concentrations in this range, the method is applicable for determining these quantities and investigating cases of low-level exposure to VOCs.

Refer to the Laboratory Method Files section for a detailed description of the laboratory methods used.

There were no changes to the lab method, lab equipment, or lab site for this component in the NHANES 2009-2010 cycle.

Laboratory Method Files

Laboratory Quality Assurance and Monitoring

Whole blood samples were processed, stored, and shipped to the Division of Laboratory Sciences, National Center for Environmental Health, Centers for Disease Control and Prevention, Atlanta, GA for analysis.

Detailed instructions on specimen collection and processing are discussed in the NHANES Laboratory Procedures Manual (LPM). Vials are stored under appropriate refrigerated (2-8°C) conditions until they are shipped to National Center for Environmental Health, for testing.

The NHANES quality assurance and quality control (QA/QC) protocols meet the 1988 Clinical Laboratory Improvement Act mandates. Detailed QA/QC instructions are discussed in the NHANES LPM.

Mobile Examination Centers (MECs)

Laboratory team performance is monitored using several techniques. NCHS and contract consultants use a structured competency assessment evaluation during visits to evaluate both the quality of the laboratory work and the quality-control procedures. Each laboratory staff member is observed for equipment operation, specimen collection and preparation; testing procedures and constructive feedback are given to each staff member. Formal retraining sessions are conducted annually to ensure that required skill levels were maintained.

Analytical Laboratories

NHANES uses several methods to monitor the quality of the analyses performed by the contract laboratories. In the MEC, these methods include performing blind split samples collected during “dry run” sessions. In addition, contract laboratories randomly perform repeat testing on 2% of all specimens.

NCHS developed and distributed a quality control protocol for all CDC and contract laboratories, which outlined the use of Westgard rules (Westgard, et al., 1981) when running NHANES specimens. Progress reports containing any problems encountered during shipping or receipt of specimens, summary statistics for each control pool, QC graphs, instrument calibration, reagents, and any special considerations are submitted to NCHS quarterly. The reports are reviewed for trends or shifts in the data. The laboratories are required to explain any identified areas of concern.

All QC procedures recommended by the manufacturers were followed. Reported results for all assays meet the CDC/NCEH Tobacco and Volatile Branch quality control and quality assurance performance criteria for accuracy and precision, similar to the Westgard rules (Caudill, et al., 2008).

Data Processing and Editing

The data were reviewed. Incomplete data or improbable values were sent to the performing laboratory for confirmation.

Analytic Notes

Refer to the 2009-2010 Laboratory Data Overview for general information on NHANES laboratory data.

Volatile Toxicant Questionnaire

A volatile toxicant questionnaire (VTQ) was administered on the mobile examination center (MEC), by trained interviewers, using the Computer-Assisted Personal Interview (CAPI) system. The VTQ section includes data about the SP’s home, activities, amount of time spent in various locations, and exposure to different chemicals over the past 48 hours. This questionnaire data can be used in conjunction with the VOC laboratory dataset and found in the Volatile Toxicant Data File in the NHANES 2009-2010 Questionnaire Data section.

Subsample Weights

Whole blood VOCs were measured in a one-half subsample of persons 12 years and older. Special sample weights are required to analyze these data properly. Specific sample weights for this subsample are included in this data file and should be used when analyzing these data.

Demographic and Other Related Variables

The analysis of NHANES laboratory data must be conducted using the appropriate survey design and demographic variables. The NHANES 2009-2010 Demographics File contains demographic data, health indicators, and other related information collected during household interviews as well as the sample design variables. The recommended procedure for variance estimation requires use of stratum and PSU variables (SDMVSTRA and SDMVPSU, respectively) in the demographic data file.

The Fasting Questionnaire File includes auxiliary information such as fasting status, length of fast, and the time of venipuncture.

This laboratory data file can be linked to the other NHANES data files using the unique survey participant identifier (i.e., SEQN).

Detection limits

The detection limits were constant for all of the analytes in the data set. Two variables are provided for each of these analytes. The variable name ending in “LC” (ex., LBDVBFLC) indicates whether the result was below the limit of detection: the value “0” means that the result was at or above the limit of detection, “1” indicates that the result was below the limit of detection. For analytes with analytic results below the lower limit of detection (ex., LBDVBFLC=1), an imputed fill value was placed in the analyte results field. This value is the lower limit of detection divided by square root of 2 (LLOD/sqrt [2]). The other variable prefixed LBX (ex., LBXVBF) provides the analytic result for that analyte.

The lower limit of detection (LLOD, in pg/mL) for whole blood - Trihalomethanes/MTBE/Nitromethane VOCs

VARIABLE NAME SAS LABEL LLOD
LBXVBF Blood Bromoform (pg/mL) 1.00
LBXVBM Blood Bromodichloromethane (pg/mL) 0.620
LBXVCF Blood Chloroform (pg/mL) 2.10
LBXVCM Blood Dibromochloromethane (pg/mL) 0.620
LBXVME Blood MTBE (pg/mL) 1.40
LBXNM Blood Nitromethane (pg/mL) 65.0

 

References

Codebook and Frequencies

SEQN - Respondent sequence number

Variable Name:
SEQN
SAS Label:
Respondent sequence number
English Text:
Respondent sequence number.
Target:
Both males and females 12 YEARS - 150 YEARS

WTSVOC2Y - VOC Subsample Weight

Variable Name:
WTSVOC2Y
SAS Label:
VOC Subsample Weight
English Text:
VOC Subsample Weight
Target:
Both males and females 12 YEARS - 150 YEARS
Code or Value Value Description Count Cumulative Skip to Item
7930.7314837 to 335126.1522 Range of Values 3736 3736
0 No Lab Result 9 3745
. Missing 0 3745

LBXVBF - Blood Bromoform (pg/mL)

Variable Name:
LBXVBF
SAS Label:
Blood Bromoform (pg/mL)
English Text:
Blood Bromoform (pg/mL)
Target:
Both males and females 12 YEARS - 150 YEARS
Code or Value Value Description Count Cumulative Skip to Item
0.71 to 310 Range of Values 3254 3254
. Missing 491 3745

LBDVBFLC - Blood Bromoform Comment Code

Variable Name:
LBDVBFLC
SAS Label:
Blood Bromoform Comment Code
English Text:
Blood Bromoform Comment Code
Target:
Both males and females 12 YEARS - 150 YEARS
Code or Value Value Description Count Cumulative Skip to Item
0 At or above detection limit 971 971
1 Below lower detection limit 2283 3254
2 Detectable result and exceeds the calibrated range of assay 0 3254
. Missing 491 3745

LBXVBM - Blood Bromodichloromethane (pg/mL)

Variable Name:
LBXVBM
SAS Label:
Blood Bromodichloromethane (pg/mL)
English Text:
Blood Bromodichloromethane (pg/mL)
Target:
Both males and females 12 YEARS - 150 YEARS
Code or Value Value Description Count Cumulative Skip to Item
0.438 to 84.1 Range of Values 3275 3275
. Missing 470 3745

LBDVBMLC - Blood Bromodichloromethane Comment Code

Variable Name:
LBDVBMLC
SAS Label:
Blood Bromodichloromethane Comment Code
English Text:
Blood Bromodichloromethane Comment Code
Target:
Both males and females 12 YEARS - 150 YEARS
Code or Value Value Description Count Cumulative Skip to Item
0 At or above detection limit 2394 2394
1 Below lower detection limit 881 3275
2 Detectable result and exceeds the calibrated range of assay 0 3275
. Missing 470 3745

LBXVCF - Blood Chloroform (pg/mL)

Variable Name:
LBXVCF
SAS Label:
Blood Chloroform (pg/mL)
English Text:
Blood Chloroform (pg/mL)
Target:
Both males and females 12 YEARS - 150 YEARS
Code or Value Value Description Count Cumulative Skip to Item
1.48 to 421 Range of Values 3269 3269
. Missing 476 3745

LBDVCFLC - Blood Chloroform Comment Code

Variable Name:
LBDVCFLC
SAS Label:
Blood Chloroform Comment Code
English Text:
Blood Chloroform Comment Code
Target:
Both males and females 12 YEARS - 150 YEARS
Code or Value Value Description Count Cumulative Skip to Item
0 At or above detection limit 3081 3081
1 Below lower detection limit 188 3269
2 Detectable result and exceeds the calibrated range of assay 0 3269
. Missing 476 3745

LBXVCM - Blood Dibromochloromethane (pg/mL)

Variable Name:
LBXVCM
SAS Label:
Blood Dibromochloromethane (pg/mL)
English Text:
Blood Dibromochloromethane (pg/mL)
Target:
Both males and females 12 YEARS - 150 YEARS
Code or Value Value Description Count Cumulative Skip to Item
0.438 to 180 Range of Values 3163 3163
. Missing 582 3745

LBDVCMLC - Blood Dibromochloromethane Comment Code

Variable Name:
LBDVCMLC
SAS Label:
Blood Dibromochloromethane Comment Code
English Text:
Blood Dibromochloromethane Comment Code
Target:
Both males and females 12 YEARS - 150 YEARS
Code or Value Value Description Count Cumulative Skip to Item
0 At or above detection limit 1851 1851
1 Below lower detection limit 1312 3163
2 Detectable result and exceeds the calibrated range of assay 0 3163
. Missing 582 3745

LBXVME - Blood MTBE (pg/mL)

Variable Name:
LBXVME
SAS Label:
Blood MTBE (pg/mL)
English Text:
Blood Methyl-tert-butyl ether (MTBE) (ng/mL)
Target:
Both males and females 12 YEARS - 150 YEARS
Code or Value Value Description Count Cumulative Skip to Item
0.99 to 448 Range of Values 3247 3247
. Missing 498 3745

LBDVMELC - Blood MTBE Comment Code

Variable Name:
LBDVMELC
SAS Label:
Blood MTBE Comment Code
English Text:
Blood Methyl-tert-butyl ether (MTBE) Comment Code
Target:
Both males and females 12 YEARS - 150 YEARS
Code or Value Value Description Count Cumulative Skip to Item
0 At or above detection limit 733 733
1 Below lower detection limit 2514 3247
2 Detectable result and exceeds the calibrated range of assay 0 3247
. Missing 498 3745

LBXNM - Blood Nitromethane (pg/mL)

Variable Name:
LBXNM
SAS Label:
Blood Nitromethane (pg/mL)
English Text:
Blood Nitromethane (pg/mL)
Target:
Both males and females 12 YEARS - 150 YEARS
Code or Value Value Description Count Cumulative Skip to Item
201 to 5830 Range of Values 2950 2950
. Missing 795 3745

LBDNMLC - Blood Nitromethane Comment Code

Variable Name:
LBDNMLC
SAS Label:
Blood Nitromethane Comment Code
English Text:
Blood Nitromethane Comment Code
Target:
Both males and females 12 YEARS - 150 YEARS
Code or Value Value Description Count Cumulative Skip to Item
0 At or above detection limit 2950 2950
1 Below lower detection limit 0 2950
2 Detectable result and exceeds the calibrated range of assay 0 2950
. Missing 795 3745