Table of Contents

Component Description

Human exposure to benzene, furfural, and 5-hydroxymethylfurfural is associated with numerous health risks, including potential or known carcinogenicity (benzene [Smith, 2010], 5-hydroxymethylfurfural [Abraham et. al., 2011]), respiratory toxicity (benzene [Bahadar et. al., 2014], furfural [NIOSH, 2019]), neurotoxicity, and birth defects (benzene [Bahadar et. al., 2014]). Human exposure may occur via multiple routes from various sources, including tobacco smoke (Smith, 2010; Talhout et al. 2006), e-cigarette aerosol (Soussy et. al., 2016; Behar et. al., 2018; Pankow et. al., 2017), automobile exhaust (Smith, 2010), industrial applications (Smith, 2010; Machado et. al., 2016), and food products (Abraham et. al., 2011; Piggott, 2003; Hodge, 1953). Due to the potential adverse health effects of these VOCs and the U.S. population’s exposure to them, improving the exposure assessment of these compounds in the general US population and/or in specific population groups is of public health significance.

VOCs can be metabolized prior to urinary excretion, so VOC exposure can be assessed by measuring their urine metabolites. An analytical method was developed to measure metabolites of benzene (trans,trans-Muconic acid [SSMUCA]; N-Acetyl-S-phenyl-L-cysteine [SSPHMA]), furfural (N-2-Furoylglycine [SSN2FG]), and 5-hydroxymethylfurfural (5-Hydroxymethyl-2-furancarboxylic acid [SSHMFA]; 5-Hydroxymethyl-2-furoylglycine [SSHMFG]), which will greatly improve our understanding of the extent of exposure to these selected VOCs.

Eligible Sample

All examined participants aged 3 to 5 years and a one-third subsample of examined participants aged 6 years and older were eligible.

Description of Laboratory Methodology

This method is a quantitative procedure to measure urinary metabolites of benzene, furfural, and 5-hydroxymethylfurfural using ultra-performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry (UPLC-ESI-MS/MS). Sample preparation involves 1:10 dilution of 50 µL urine samples in ammonium formate buffer, pH 2.9. Chromatographic separation of each prepared urine specimen is achieved by using a Waters Acquity UPLC HSS fluoro-phenyl (PFP) column using a mobile phase A (0.02% formic acid) and a mobile phase B (methanol). The eluate from the column is ionized using electrospray ionization, which is used to generate and transmit ions into the mass spectrometer. Comparison of relative response factors (ratio of native analyte to stable isotope-labeled internal standard) with known standard concentrations yields individual analyte concentrations in each sample (Bhandari et. al., 2019). 

The VOC Metabolites II dataset was produced by applying an improved method for measuring N-Acetyl-S-phenyl-L-cysteine (PHMA). NHANES cycle 2015-2016 and prior measured PHMA (NHANES variable URXPMA, dataset UVOC_I) in urine samples at neutral pH. Conversely, NHANES cycle 2017-2018 measured PHMA (NHANES variable SSPHMA) in urine samples prepared at pH 2.9. This acid treatment converts the PHMA precursor, i.e., pre-PHMA to PHMA; thus the new method quantifies both free PHMA and PHMA formed from the acid dehydration of pre-PHMA (Bhandari et. al., 2019). This new PHMA measure more accurately assesses benzene exposure (Sterz et. al., 2010). The PHMA results reported in NHANES 2017-2018 (SSPHMA) should not be directly compared with PHMA (URXPMA) reported in previous NHANES analyses (Tevis et. al., 2020).

Refer to the Laboratory Method Files section for a detailed description of the laboratory methods used.

This is a new component in the 2017-2018 survey cycle.

Laboratory Method Files

Urinary metabolites of Benzene, Furfural, 5-Hydroxymethylfurfural, and N-Methyl-2-pyrrolidone Laboratory Procedure Manual (2017-2018) (September 2022)

Laboratory Quality Assurance and Monitoring

Urine specimens were processed, stored, and shipped to the Division of Laboratory Sciences, National Center for Environmental Health, Centers for Disease Control and Prevention, Atlanta GA for analysis.

Detailed instructions on specimen collection and processing are discussed in the 2017-2018 NHANES Laboratory Procedures Manual (LPM). Vials are stored under appropriate frozen (–30°C) conditions until they are shipped to National Center for Environmental Health for testing.

The NHANES quality assurance and quality control (QA/QC) protocols meet the 1988 Clinical Laboratory Improvement Amendments mandates. Detailed QA/QC instructions are discussed in the NHANES LPM.

Mobile Examination Centers (MECs)

Laboratory team performance is monitored using several techniques. NCHS and contract consultants use a structured competency assessment evaluation during visits to evaluate both the quality of the laboratory work and the QC procedures. Each laboratory staff member is observed for equipment operation, specimen collection and preparation; testing procedures and constructive feedback are given to each staff member. Formal retraining sessions are conducted annually to ensure that required skill levels were maintained.

Analytical Laboratories

NHANES uses several methods to monitor the quality of the analyses performed by the CDC and contract laboratories. In the MEC, these methods include performing blind split samples collected during “dry run” sessions. In addition, contract laboratories randomly perform repeat testing on 2% of all specimens.

NCHS developed and distributed a QC protocol for all CDC and contract laboratories, which outlined the use of Westgard rules (Westgard, et al., 1981) when testing NHANES specimens. Progress reports containing any problems encountered during shipping or receipt of specimens, summary statistics for each control pool, QC graphs, instrument calibration, reagents, and any special considerations are submitted to NCHS quarterly. The reports are reviewed for trends or shifts in the data. The laboratories are required to explain any identified areas of concern.

All QC procedures recommended by the manufacturers were followed. Reported results for all assays meet the Division of Laboratory Sciences’ QA/QC performance criteria for accuracy and precision, similar to the Westgard rules (Caudill et al., 2008).

Data Processing and Editing

The data were reviewed. Incomplete data or improbable values were sent to the performing laboratory for confirmation.

Analytic Notes

Refer to the 2017-2018 Laboratory Data Overview for general information on NHANES laboratory data.

There are over 800 laboratory tests performed on NHANES participants. However, not all participants provided biospecimens or enough volume for all the tests to be performed. Additionally, availability of specimens for surplus projects is lower than for other laboratory tests performed on NHANES participants. The specimen availability can also vary by age or other population characteristics. Analysts should evaluate the extent of missing data in the dataset related to the outcome of interest as well as any predictor variables used in the analyses to determine whether additional re-weighting for item non-response is necessary.

Please refer to the NHANES Analytic Guidelines and the on-line NHANES Tutorial for details on the use of sample weights and analytic issues.

Subsample Weights

The analytes included in this dataset were measured in all examined participants aged 3-5 years, and in a one-third subsample of participants 6 years and older. Special sample weights are required to analyze these data properly. Specific sample weights for this subsample, WTSSAJ2Y, are included in this data file and should be used when analyzing these data. The sample weights created for this file used the examination sample weight, i.e., WTMEC2YR, as the base weight. The base weight was adjusted for additional nonresponse to these lab tests and re-poststratified to the population total using sex, age, and race/ethnicity. Participants who were part of the eligible population but who did not provide a urine specimen, or did not have sufficient volume of biospecimens, or who did not give consent for their specimens to be used for future research are included in the file but they have a sample weight assigned “0” in their records.

Demographic and Other Related Variables

The analysis of NHANES laboratory data must be conducted using the appropriate survey design and demographic variables. The NHANES 2017-2018 Demographics File contains demographic data, health indicators, and other related information collected during household interviews as well as the sample design variables. The recommended procedure for variance estimation requires use of stratum and PSU variables (SDMVSTRA and SDMVPSU, respectively) in the demographic data file.

This laboratory data file can be linked to the other NHANES data files using the unique survey participant identifier (i.e., SEQN).

Starting in the 2015-2016 NHANES cycle, the variable URXUCR (urine creatinine) will not be reported in this file. URXUCR can be found in the data file titled “Albumin & Creatinine – Urine”.

Detection Limits

The detection limits were constant for the analytes in the data set. Two variables are provided for each of these analytes. The variable named ending in “L” (ex., SSPHMAL) indicates whether the result was below the limit of detection: the value “0” means that the result was at or above the limit of detection, “1” indicates that the result was below the limit of detection. For analytes with analytic results below the lower limit of detection (ex., SSPHMAL=1), an imputed fill value was placed in the analyte results field. This value is the lower limit of detection divided by the square root of 2 (LLOD/sqrt [2]). The other variable prefixed URX (ex., SSPHMA) provides the analytic result for the analyte. All data are rounded to three significant figures or three decimal places, whichever is less precise.

The lower limit of detection (LLOD, in ng/mL) for SSHMFA, SSHMFG, SSMUCA, SSN2FG, and SSPHMA:

Variable Name

Analyte Name

LLOD

SSHMFA

5-Hydroxymethyl-2-furancarboxylic acid (ng/mL)

36.1

SSHMFG

5-Hydroxymethyl-2-furoylglycine (ng/mL)

16.0

SSMUCA

trans, trans-Muconic acid (ng/mL)

9.81

SSN2FG

N-2-Furoylglycine (ng/mL)

64.4

SSPHMA

Phenylmercapturic acid (ng/mL)

0.150

References

Codebook and Frequencies

SEQN - Respondent sequence number

Variable Name:
SEQN
SAS Label:
Respondent sequence number
English Text:
Respondent sequence number.
Target:
Both males and females 3 YEARS - 150 YEARS

WTSSAJ2Y - Surplus specimen A 17-18 2 year weights

Variable Name:
WTSSAJ2Y
SAS Label:
Surplus specimen A 17-18 2 year weights
English Text:
Surplus specimen 2 year weights A for 2017-2018
Target:
Both males and females 3 YEARS - 150 YEARS
Code or Value Value Description Count Cumulative Skip to Item
6597.317346 to 1670271.9768 Range of Values 2226 2226
0 Participants 3+ years with no surplus lab specimen 753 2979
. Missing 0 2979

SSHMFA - 5-Hydrxymthl-2-furancrbxylc acid (ng/mL)

Variable Name:
SSHMFA
SAS Label:
5-Hydrxymthl-2-furancrbxylc acid (ng/mL)
English Text:
5-Hydroxymethyl-2-furancarboxylic acid (ng/mL)
Target:
Both males and females 3 YEARS - 150 YEARS
Code or Value Value Description Count Cumulative Skip to Item
25.5 to 429000 Range of Values 2226 2226
. Missing 753 2979

SSHMFAL - 5-Hydrxymthl-2-furancrbxylc acid comt

Variable Name:
SSHMFAL
SAS Label:
5-Hydrxymthl-2-furancrbxylc acid comt
English Text:
5-Hydroxymethyl-2-furancarboxylic acid comment code
Target:
Both males and females 3 YEARS - 150 YEARS
Code or Value Value Description Count Cumulative Skip to Item
0 At or above the detection limit 2191 2191
1 Below lower detection limit 35 2226
. Missing 753 2979

SSHMFG - 5-Hydroxymethyl-2-furoylglycine (ng/mL)

Variable Name:
SSHMFG
SAS Label:
5-Hydroxymethyl-2-furoylglycine (ng/mL)
English Text:
5-Hydroxymethyl-2-furoylglycine (ng/mL)
Target:
Both males and females 3 YEARS - 150 YEARS
Code or Value Value Description Count Cumulative Skip to Item
11.3 to 37100 Range of Values 2226 2226
. Missing 753 2979

SSHMFGL - 5-Hydroxymethyl-2-furoylglycine comt

Variable Name:
SSHMFGL
SAS Label:
5-Hydroxymethyl-2-furoylglycine comt
English Text:
5-Hydroxymethyl-2-furoylglycine comment code
Target:
Both males and females 3 YEARS - 150 YEARS
Code or Value Value Description Count Cumulative Skip to Item
0 At or above the detection limit 2087 2087
1 Below lower detection limit 139 2226
. Missing 753 2979

SSMUCA - trans, trans-Muconic acid (ng/mL)

Variable Name:
SSMUCA
SAS Label:
trans, trans-Muconic acid (ng/mL)
English Text:
trans, trans-Muconic acid (ng/mL)
Target:
Both males and females 3 YEARS - 150 YEARS
Code or Value Value Description Count Cumulative Skip to Item
6.94 to 15800 Range of Values 2226 2226
. Missing 753 2979

SSMUCAL - trans, trans-Muconic acid comment code

Variable Name:
SSMUCAL
SAS Label:
trans, trans-Muconic acid comment code
English Text:
trans, trans-Muconic acid comment code
Target:
Both males and females 3 YEARS - 150 YEARS
Code or Value Value Description Count Cumulative Skip to Item
0 At or above the detection limit 2061 2061
1 Below lower detection limit 165 2226
. Missing 753 2979

SSN2FG - N-2-Furoylglycine (ng/mL)

Variable Name:
SSN2FG
SAS Label:
N-2-Furoylglycine (ng/mL)
English Text:
N-2-Furoylglycine (ng/mL)
Target:
Both males and females 3 YEARS - 150 YEARS
Code or Value Value Description Count Cumulative Skip to Item
45.5 to 279000 Range of Values 2226 2226
. Missing 753 2979

SSN2FGL - N-2-Furoylglycine comment code

Variable Name:
SSN2FGL
SAS Label:
N-2-Furoylglycine comment code
English Text:
N-2-Furoylglycine comment code
Target:
Both males and females 3 YEARS - 150 YEARS
Code or Value Value Description Count Cumulative Skip to Item
0 At or above the detection limit 2217 2217
1 Below lower detection limit 9 2226
. Missing 753 2979

SSPHMA - Phenylmercapturic acid (ng/mL)

Variable Name:
SSPHMA
SAS Label:
Phenylmercapturic acid (ng/mL)
English Text:
Phenylmercapturic acid (ng/mL)
Target:
Both males and females 3 YEARS - 150 YEARS
Code or Value Value Description Count Cumulative Skip to Item
0.106 to 26.6 Range of Values 2226 2226
. Missing 753 2979

SSPHMAL - Phenylmercapturic acid comment code

Variable Name:
SSPHMAL
SAS Label:
Phenylmercapturic acid comment code
English Text:
Phenylmercapturic acid comment code
Target:
Both males and females 3 YEARS - 150 YEARS
Code or Value Value Description Count Cumulative Skip to Item
0 At or above the detection limit 911 911
1 Below lower detection limit 1315 2226
. Missing 753 2979