Chronic liver disease and cirrhosis are significant contributors to morbidity and mortality in the U.S. population (Singh et al., 2013; Tapper and Parikh, 2018; Yoon, 2018). With the obesity epidemic, nonalcoholic fatty-liver disease is considered the most common cause of chronic liver disease in U.S. adults and children. Other important causes of chronic liver disease in the general population include alcoholic liver disease and chronic viral hepatitis infections (B or C).
The main goals of the NHANES liver ultrasound transient elastography (variable name prefix LUX) component are to provide objective measures for two important liver disease manifestations: liver fibrosis (scarring in the liver) and hepatic steatosis (fat in the liver). A healthy liver is usually soft and flexible, but a person with liver disease tends to have a liver that is stiff. Liver fibrosis was measured by FibroScan®, which uses ultrasound and the vibration controlled transient elastography (VCTETM ) to derive liver stiffness. The device also simultaneously measures the ultrasound attenuation related to the presence of hepatic steatosis and records the controlled attenuation parameter (CAPTM) as the indicator for the fatness in the liver. Elastography has been evaluated by others for its accuracy to assess liver steatosis and liver fibrosis (Tang et al., 2015, Castéra et al., 2005, Barr et al., 2015).
All participants 12 years and older in the NHANES August 2021-August 2023 sample were eligible. Participants were excluded if they (1) were unable to lie down on the exam table, (2) were pregnant (or unsure if pregnant) at the time of their exam, or a urine could not be obtained to test for pregnancy, (3) had an implanted electronic medical device, or (4) were wearing a bandage or had lesions on the right side of their abdomen by the ribs (where measurements would be taken).
A detailed description of the procedures was documented in the August 2021 – August 2023 Liver Ultrasound Transient Elastography Procedures Manual of this component. The elastography measurements were obtained in the NHANES Mobile Examination Center (MEC), using the FibroScan® model 502 V2 Touch equipped with a medium (M) or extra-large (XL) wand (probe).
With FibroScan®, a mechanical vibration of mild amplitude and low frequency (50Hz) is transmitted through the intercostal space using a vibrating tip contacting the skin. The vibration induces a shear wave that propagates through the liver. The displacements induced by the shear waves were tracked and measured using pulse echo ultrasound acquisition algorithms. The shear wave velocity is related directly to tissue stiffness; with harder tissues, there is faster shear wave propagation. Using the Young modulus, the velocity is converted into liver stiffness, and expressed in kilopascals. In systematic reviews comparing vibration controlled transient elastography (VCTETM) to biopsy (as a gold standard) for the detection of severe liver fibrosis, the mean area under the receiver operating characteristic (ROC) curve was 0.89 (95% CI, 0.88-0.91) (Tsochatzis et al., 2011, Friedrich-Rust et al., 2008) and the overall sensitivity and specificity were 82% (95% CI, 78-86%) and 86% (95% CI 0.80-0.91). In addition to the high accuracy, meta-analyses have demonstrated FibroScan® results carry significant prognostic value (Singh et al., 2013). Transient elastography has been FDA approved as a test for the evaluation of liver fibrosis.
The FibroScan® machine has also incorporated a novel physical parameter (controlled attenuation parameter or CAPTM), which measures the ultrasound attenuation related to the presence of hepatic steatosis. The CAP measurement is recorded simultaneously with the liver stiffness measurement. The accuracy of the CAP measurement for the detection of steatosis against biopsy has been reported in few studies; for steatosis ≥10%, the area under the ROC curve is 0.81, with a sensitivity and specificity of 76% and 79%; for steatosis >34% these values were 0.80, 79% and 71%, respectively (Myers et al., 2012, de Ledinghen V et al., 2016, Sasso et al., 2016).
The elastography exam was performed by NHANES examiners, including health technicians (HTs), radiology technicians (RTs), and clinicians (registered nurse), who were trained and certified by NHANES staff and the equipment manufacturer (EchosensTM North America). The exams were performed according to the manufacturer guidelines. To help maintain a standardized data quality, the machine conducts and displays several quality control (QC) measures during the test: 1) the median of all valid measurements performed during the examination; 2) interquartile range (IQR) which represents the interval around the median within which 50% of all valid measurements will fall; and 3) IQR/M: the ratio of the IQR to the median stiffness. All these QC indexes were recalculated after each new measurement. Examiners were trained to take 10 valid measurements with an IQR/M ratio less than 30%.
If the first 10 measurements taken had an IQR/M ≥ 30%, the examiner may choose to capture additional measurements until the IQR/M index was lower than 30%. The examiner also has the option to delete outlier measurements to lower the IQR/M from the list of valid measurements. It should be noted that examiners were only allowed to delete measurements from the beginning of the measurements. Once a measurement was chosen to be deleted, any measurements taken before the chosen one will be eliminated from the exam as well. This is to reduce bias, so examiners were unable to hand select which measurement(s) to delete.
The QC criteria of IQR/M <30% is to reduce variability and improve validity by taking measurements that result in few outliers. Multiple factors can affect the measurement and result in outliers, for example, a participant moves during the exam, or technical issues, such as the placement of the probe is not centered over the liver or perpendicular, or if structures such as lung or ribs appear while the measurement is captured. Participants with a lot of adipose tissue sometimes may make it difficult for examiners to capture 10 valid measurements. Because of the twelve-minute time limit and the challenge of locating the proper site to administer the exam on the body, examiners could end up retaining fewer than 10 valid measurements.
A detailed description of quality assurance and quality control measures considered for this component can be found in the August 2021 – August 2023 Procedures Manual. Briefly, the NHANES examiners completed a 2-day training program with survey staff and an expert FibroScan® Technician (reference examiner). The training included an overview of the component and demonstrations conducted by the reference examiner with volunteer subjects. The reference examiner reviewed and demonstrated the proper technique of the FibroScan® examination. Supervised practice exercises followed, conducted with several volunteer subjects. The reference examiner would certify the examiner after observing 3 satisfactory exams.
NHANES staff members and an external university-based medical epidemiologist with expertise in chronic liver disease monitored MEC staff performance in the field through periodic visits and direct observations. Examiner performance was also monitored using data reviews for each technician or clinician compared to all others and annual reference examiner refresher training.
Multiple times per year NHANES staff would select a sample of the original FibroScan® PDF files obtained by the examiners in the MEC for re-review. The samples selected for review include ones from new and experienced examiners, and participants with: 1) extreme stiffness (E), CAP, or E-IQR values, 2) stiffness (E) or CAP values that seemed unusual for younger participants, or 3) inconsistent extreme stiffness (E) and CAP values in the same person (i.e., low stiffness (E) and high CAP or high stiffness (E) and low CAP).
Annual FibroScan® wand calibration was performed by the manufacturer and software updates were performed according to manufacturer recommendations. In addition, NHANES used four shear wave liver fibrosis phantoms (CIRS Model 039) for determining variances within and between FibroScan® machines and probes over time.
Information obtained by staff in the MEC regarding pregnancy status/test results, fasting times, possible exam exclusions, and other comments were recorded in the NHANES database during the participant’s MEC visit. All measures recorded by the FibroScan® machines were directly transferred via the Integrated Survey Information System to the NHANES database system immediately after each exam. Examiners were instructed to visually verify that the values transferred correctly.
Computerized data quality control procedures were performed to check for completeness and data validity and to identify logical inconsistencies and extreme data values (e.g., fasting times lasting more than 40 hours) and rare deviations in the protocol (e.g., technical error for number of measures recorded or duplicate files due to exam restarts).
Prior to data release, NHANES staff reviewed extreme values and cross-checked with other available data for verification and reviewed free-text comments noted by MEC staff and made edits or corrections as appropriate.
The liver elastography exam status code (LUAXSTAT) was created and indicates the following for each participant:
1 = Complete exam (i.e., fasting time of at least 3 hours, 10 or more complete stiffness (E) measures, and a liver stiffness interquartile (IQRe) range / median E <30%).
2 = Partial exam (i.e., either a fasting time < 3 hours, < 10 complete stiffness (E) measures, or a liver stiffness interquartile (IQRe) range/median E 30% or higher).
3 = Ineligible participant (see eligibility criteria above).
4= Not done (i.e., refusal, limited time during exam visit, other).
The number of measures attempted (LUANMTGP) and the number of measures recorded (LUANMVGP), using the final wand, were categorized at high end to 20 to 29, and 30 or more.
FibroScan® measures were not edited, and there are no imputed values in this file.
Elastography results were not reported to participants if they had <10 complete stiffness (E) measures or liver stiffness interquartile (IQRe) range/median E ≥30%, or fasted <3 hours, as recommended by the elastography equipment manufacturer. An exception to these criteria was permitted if the participant had an E value below the referral criteria and had at least 10 complete stiffness measures, even though the 3-hour fasting time was not satisfied. In this data file, elastography results are included for all participants regardless of the number of complete stiffness measures, the IQRe value, or the length of fast.
As stated above no changes were made to the stiffness, controlled attenuation parameter, IQRe, or IQRc values obtained from the FibroScan® machine. Analysts should be aware that some extreme values may be present. Extreme values may be to the result of difficulty obtaining the measures due to participant body habitus (especially those who are obese or who have narrow intercostal spaces) or may represent truly high values.
Sample weights: the NHANES examination sample weights should be used to analyze elastography data unless it is merged with a more restrictive data file, such as the morning fasting sample, then use the sample weight appropriate for that more selective group.
Please refer to the NHANES Analytic Guidelines and the on-line NHANES Tutorials for further details on the use of sample weights and other analytic issues. Both are available on the NHANES website.
Code or Value | Value Description | Count | Cumulative | Skip to Item |
---|---|---|---|---|
1 | Complete | 6280 | 6280 | LUAPNME |
2 | Partial | 514 | 6794 | |
3 | Ineligible | 201 | 6995 | LUARXIN |
4 | Not done | 204 | 7199 | LUARXND |
. | Missing | 0 | 7199 |
Code or Value | Value Description | Count | Cumulative | Skip to Item |
---|---|---|---|---|
1 | Fasting < 3hrs | 165 | 165 | LUAPNME |
2 | Unable to obtain 10 valid measures | 138 | 303 | LUAPNME |
3 | IQR/M >30% | 211 | 514 | LUAPNME |
. | Missing | 6685 | 7199 |
Code or Value | Value Description | Count | Cumulative | Skip to Item |
---|---|---|---|---|
1 | Participant refusal | 106 | 106 | LUANMTGP |
2 | Limited time | 40 | 146 | LUANMTGP |
3 | Other (e.g. physical or technical limitations ) | 58 | 204 | LUANMTGP |
. | Missing | 6995 | 7199 |
Code or Value | Value Description | Count | Cumulative | Skip to Item |
---|---|---|---|---|
1 | Pregnant/ Unable to get urine to test for pregnancy | 67 | 67 | LUANMTGP |
2 | Other (e.g. insulin pump or other implantable electronic device) | 134 | 201 | LUANMTGP |
. | Missing | 6998 | 7199 |
Code or Value | Value Description | Count | Cumulative | Skip to Item |
---|---|---|---|---|
M | M | 5158 | 5158 | |
XL | XL | 1574 | 6732 | |
< blank > | Missing | 467 | 7199 |
Code or Value | Value Description | Count | Cumulative | Skip to Item |
---|---|---|---|---|
0 | 0 | 32 | 32 | |
1 | 1 | 13 | 45 | |
2 | 2 | 6 | 51 | |
3 | 3 | 8 | 59 | |
4 | 4 | 7 | 66 | |
5 | 5 | 11 | 77 | |
6 | 6 | 4 | 81 | |
7 | 7 | 7 | 88 | |
8 | 8 | 4 | 92 | |
9 | 9 | 14 | 106 | |
10 | 10 | 4945 | 5051 | |
11 | 11 | 974 | 6025 | |
12 | 12 | 334 | 6359 | |
13 | 13 | 138 | 6497 | |
14 | 14 | 89 | 6586 | |
15 | 15 | 51 | 6637 | |
16 | 16 | 21 | 6658 | |
17 | 17 | 15 | 6673 | |
18 | 18 | 11 | 6684 | |
19 | 19 | 9 | 6693 | |
20 | 20 to 29 | 31 | 6724 | |
30 | 30 or more | 8 | 6732 | |
. | Missing | 467 | 7199 |
Code or Value | Value Description | Count | Cumulative | Skip to Item |
---|---|---|---|---|
0 | Not done | 467 | 467 | |
1 | 1 | 1 | 468 | |
2 | 2 | 1 | 469 | |
3 | 3 | 3 | 472 | |
5 | 5 | 1 | 473 | |
6 | 6 | 1 | 474 | |
7 | 7 | 2 | 476 | |
8 | 8 | 2 | 478 | |
9 | 9 | 4 | 482 | |
10 | 10 | 2361 | 2843 | |
11 | 11 | 1186 | 4029 | |
12 | 12 | 576 | 4605 | |
13 | 13 | 445 | 5050 | |
14 | 14 | 326 | 5376 | |
15 | 15 | 247 | 5623 | |
16 | 16 | 163 | 5786 | |
17 | 17 | 144 | 5930 | |
18 | 18 | 131 | 6061 | |
19 | 19 | 116 | 6177 | |
20 | 20-29 | 538 | 6715 | |
30 | 30 or more | 484 | 7199 | |
. | Missing | 0 | 7199 |
Code or Value | Value Description | Count | Cumulative | Skip to Item |
---|---|---|---|---|
1.5 to 75 | Range of Values | 6700 | 6700 | |
. | Missing | 499 | 7199 |
Code or Value | Value Description | Count | Cumulative | Skip to Item |
---|---|---|---|---|
0 to 72.8 | Range of Values | 6687 | 6687 | |
. | Missing | 512 | 7199 |
Code or Value | Value Description | Count | Cumulative | Skip to Item |
---|---|---|---|---|
0 to 1720.7 | Range of Values | 6687 | 6687 | |
. | Missing | 512 | 7199 |
Code or Value | Value Description | Count | Cumulative | Skip to Item |
---|---|---|---|---|
100 to 400 | Range of Values | 6699 | 6699 | |
. | Missing | 500 | 7199 |
Code or Value | Value Description | Count | Cumulative | Skip to Item |
---|---|---|---|---|
0 to 208 | Range of Values | 6686 | 6686 | |
. | Missing | 513 | 7199 |