Vitamin D is functionally a hormone rather than a vitamin, and in conjunction with parathyroid hormone and calcitonin, it is one of the most important biological regulators of calcium metabolism. Vitamin D and its main metabolites may be categorized into two families of secosteroids: cholecalciferol (vitamin D3) and ergocalciferol (vitamin D2). Both vitamins D3 and D2 are enzymatically hydroxylated in the liver to 25-hydroxy forms and then further metabolized in the kidney to the bioactive 1,25-dihydroxy forms. Although 25-hydroxyvitamin D (25OHD) is not the bioactive form, it is the predominant circulating form of vitamin D, and thus, it is considered to be the most reliable index of vitamin D status (Olkowski, 2003; Saenger, 2006). Vitamin D3 is a naturally occurring form of vitamin D that is produced in the skin after 7-dehydrocholesterol is exposed to UV-B radiation. Commercially, vitamin D2 is produced by UV irradiation of plant-derived ergosterol. The two forms differ in the structures of their side chains, but they are metabolized identically. Good sources of vitamin D3 are fatty fish, while mushrooms provide a good source of vitamin D2. Both forms are used for fortification of a limited selection of foods including milk, juice, margarines, cheese and nutrition bars. Because these two parent compounds provide various contributions to vitamin D status, it is informative when both forms are measured separately (Olkowski, 2003; Saenger, 2006).
The measurement of 25OHD is becoming increasingly important in the management of patients with various disorders of calcium metabolism associated with rickets, osteomalacia, nutritional and renal osteodystrophy, hypoparathyroidism, and postmenopausal osteoporosis (Holick, 2005). These data will be used to estimate deficiencies and toxicities of specific nutrients in the population and subgroup, to provide population reference data, and to estimate the contribution of diet, supplements, and other factors to serum levels of nutrients. Data will be used in research to further define nutrient requirements as well as optimal levels for disease prevention and health promotion.
Examined participants aged 1 year and older were eligible.
The test principle for the CDC method utilizes high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) for the quantitative detection of 25-hydroxyvitamin D3 (25OHD3), 3-epi-25-hydroxyvitamin D3 (epi-25OHD3), and 25-hydroxyvitamin D2 (25OHD2) in human serum. The analytes are chromatographically separated generally on one of three pentaflurophenyl (PFP) columns. Mobile phase composition for optimized chromatography varies slightly for the three columns but is between 69% and 72% methanol in water. The composition of the solution added to the serum prior to extraction, the solution used for reconstitution, and the needle wash should match that used for the mobile phase.
Refer to the Laboratory Method Files section for a detailed description of the methods used.
There were no changes to the lab method, lab equipment, or lab site for this component during the NHANES August 2021-August 2023 cycle.
Vitamin D (September 2024)
Serum specimens were processed, stored, and shipped to the Division of Laboratory Sciences, National Center for Environmental Health, Centers for Disease Control and Prevention, Atlanta, GA for analysis.
Detailed instructions on specimen collection and processing are discussed in the NHANES Laboratory Procedures Manual (LPM). Vials are stored under appropriate frozen (–30°C) conditions until they are shipped to the National Center for Environmental Health for testing.
The NHANES quality assurance and quality control (QA/QC) protocols meet the 1988 Clinical Laboratory Improvement Amendments mandates. Detailed QA/QC instructions are discussed in the NHANES LPM.
Mobile Examination Centers (MECs)
Laboratory team performance is monitored using several techniques. NCHS and contract consultants use a structured competency assessment evaluation during visits to evaluate both the quality of the laboratory work and the QC procedures. Each laboratory staff member is observed for equipment operation, specimen collection and preparation; testing procedures and constructive feedback are given to each staff member. Formal retraining sessions are conducted annually to ensure that required skill levels are maintained.
Analytical Laboratories
NHANES uses several methods to monitor the quality of the analyses performed by the laboratories. In the MEC, these methods include performing blind split samples collected on “dry run” sessions. In addition, contract laboratories randomly perform repeat testing on 2% of all specimens.
NCHS developed and distributed a QC protocol for all the contract laboratories, which outlined the use of Westgard rules (Westgard, et. al., 1981) when testing NHANES specimens. Progress reports containing any problems encountered during shipping or receipt of specimens, summary statistics for each control pool, QC graphs, instrument calibration, reagents, and any special considerations are submitted to NCHS periodically. The reports are reviewed for trends or shifts in the data. The laboratories are required to explain any areas of concern.
All QC procedures recommended by the manufacturers were followed. Reported results for all assays meet the Division of Laboratory Science’s QA/QC performance criteria for accuracy and precision, similar to the Westgard rules (Caudill, et. al., 2008).
The data were reviewed. Incomplete data or improbable values were sent to the performing laboratory for confirmation.
There are over 800 laboratory tests performed on NHANES participants. However, not all participants provided biospecimens or enough volume for all the tests to be performed. The specimen availability can also vary by age or other population characteristics. Analysts should evaluate the extent of missing data in the dataset related to the outcome of interest as well as any predictor variables used in the analyses to determine whether additional re-weighting for item non-response is necessary.
Please refer to the NHANES Analytic Guidelines and the on-line NHANES Tutorial for details on the use of sample weights and other analytic issues.
Phlebotomy Weights
For the August 2021-August 2023 cycle, analysis of nonresponse patterns for the phlebotomy component in the MEC examination revealed differences by age group and race/ethnicity, among other characteristics. For example, approximately 67% of children aged 1-17 years who were examined in the MEC provided a blood specimen through phlebotomy, while 95% of examined adults aged 18 and older provided a blood specimen. Therefore, an additional phlebotomy weight, WTPH2YR, has been included in this data release to address possible nonresponse bias. Participants who are eligible but did not provide a blood specimen have their phlebotomy weight assigned a value of “0” in their records. The phlebotomy weight should be used for analyses that use variables derived from blood analytes, and is included in all relevant data files.
Demographic and Other Related Variables
The analysis of NHANES laboratory data must be conducted using the appropriate survey design and demographic variables. The NHANES August 2021-August 2023 Demographics File contains demographic data, health indicators, and other related information collected during household interviews as well as the sample design variables. The recommended procedure for variance estimation requires use of stratum and PSU variables (SDMVSTRA and SDMVPSU, respectively) in the demographic data file.
The Fasting Questionnaire File includes auxiliary information such as fasting status, the time of venipuncture, and the conditions precluding venipuncture.
This laboratory data file can be linked to the other NHANES data files using the unique survey participant identifier (i.e., SEQN).
Detection Limits
The detection limits were constant for all of the analytes in the data set. The SAS variable name ending in LC (ex., LBXVD2LC) indicates whether the result was below the limit of detection: the value “0” means that the result was at or above the limit of detection, “1” indicates that the result was below the limit of detection. The other variable prefixed LBX (ex., LBXVIDMS) provides the result for the analyte. For analytes with analytic results below the lower limit of detection (ex., LBXVIDLC=1), an imputed fill value was placed in the analyte results field. This value is the lower limit of detection divided by the square root of 2 (LLOD/sqrt (2)).
The lower limits of detection (LLOD in nmol/L) for Vitamin D metabolites are:
Variable Name | Analyte Description | LLOD |
---|---|---|
LBXVD2MS | 25-hydroxyvitamin D2 | 2.216 nmol/L |
LBXVD3MS | 25-hydroxyvitamin D3 | 0.439 nmol/L |
LBXVE3MS | epi-25-hydroxyvitamin D3 | 0.755 nmol/L |
Analysis of 25-Hydroxyvitamin D Data from NHANES III (1988-1994) and NHANES 2001-2006, with NHANES data collected since 2007
The LC-MS/MS-equivalent 25-Hydroxyvitamin D data are recommended for all analyses, but especially for analyzing secular trends for serum vitamin D involving NHANES III (1988-1994), NHANES 2001-2006 and NHANES data collected since 2007. Users are strongly encouraged to review the Analytical Note for 25-Hydroxyvitamin D Data Analysis (cdc.gov) prior to the analysis.
Code or Value | Value Description | Count | Cumulative | Skip to Item |
---|---|---|---|---|
4391.8220579 to 253478.77765 | Range of Values | 7626 | 7626 | |
0 | No blood sample provided | 1101 | 8727 | |
. | Missing | 0 | 8727 |
Code or Value | Value Description | Count | Cumulative | Skip to Item |
---|---|---|---|---|
7.97 to 424 | Range of Values | 7307 | 7307 | |
. | Missing | 1420 | 8727 |
Code or Value | Value Description | Count | Cumulative | Skip to Item |
---|---|---|---|---|
0 | At or above the detection limit | 7307 | 7307 | |
1 | Below lower detection limit | 0 | 7307 | |
. | Missing | 1420 | 8727 |
Code or Value | Value Description | Count | Cumulative | Skip to Item |
---|---|---|---|---|
1.57 to 239 | Range of Values | 7307 | 7307 | |
. | Missing | 1420 | 8727 |
Code or Value | Value Description | Count | Cumulative | Skip to Item |
---|---|---|---|---|
0 | At or above the detection limit | 1447 | 1447 | |
1 | Below lower detection limit | 5860 | 7307 | |
. | Missing | 1420 | 8727 |
Code or Value | Value Description | Count | Cumulative | Skip to Item |
---|---|---|---|---|
4.1 to 422 | Range of Values | 7308 | 7308 | |
. | Missing | 1419 | 8727 |
Code or Value | Value Description | Count | Cumulative | Skip to Item |
---|---|---|---|---|
0 | At or above the detection limit | 7308 | 7308 | |
1 | Below lower detection limit | 0 | 7308 | |
. | Missing | 1419 | 8727 |
Code or Value | Value Description | Count | Cumulative | Skip to Item |
---|---|---|---|---|
0.54 to 62.8 | Range of Values | 7238 | 7238 | |
. | Missing | 1489 | 8727 |
Code or Value | Value Description | Count | Cumulative | Skip to Item |
---|---|---|---|---|
0 | At or above the detection limit | 7168 | 7168 | |
1 | Below lower detection limit | 70 | 7238 | |
. | Missing | 1489 | 8727 |