Cruise Ship: Disney Magic Cruise Line: Disney Cruise Lines Inspection Date: 06/05/2004 Inspection Score: 97
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 34
Site: Other-LUMIERES GALLEY
Violation: THE SOUP STATION'S BAIN MARIE SUPPLY WATER LINE LEAKED.
Recommendation: 7.7.3.3.1 A plumbing system in a food area shall be maintained in good repair.
Item No.: 33
Site: Other-LUMIERES GALLEY
Violation: SOIL AND POOLED LIQUID WAS NOTED IN TECHNICAL AREAS OF THE LUMIERES GALLEY.
Recommendation: 7.7.4.2.1 Decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, shall be cleaned as often as necessary.
Item No.: 33
Site: Other-PASTRY
Violation: GROUT WAS MISSING FROM DECK TILES IN THE DRY STORAGE WALK-IN UNIT # 51.
Recommendation: 7.7.4.2.3 Decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas, shall be maintained in good repair.
Item No.: 28
Site: Other-PARROT'S CAY GALLEY
Violation: CONDENSATE FROM THE VENTILATION HOOD WAS DRIPPING ONTO CLEAN GLASSES AS THEY EXITED THE GLASSWASH MACHINE.
Recommendation: 7.5.7.3.1 Cleaned equipment and utensils, laundered linens, and single-service and single-use articles shall be stored: (1) In a clean, dry location; (2) Where they are not exposed to splash, dust, or other contamination; and (3) At least 15 centimeters (6 inches) above the deck.
Item No.: 37
Site: Other-PARROT'S CAY GALLEY
Violation: THE VENTILATION HOOD ABOVE THE GLASSWASH UNIT DID NOT ADEQUATELY REMOVE THE CONDENSATE.
Recommendation: 7.4.2.4.1 Exhaust ventilation hood systems in food preparation and warewashing areas including components such as hoods, fans, guards, and ducting shall be designed to prevent grease or condensation from draining or dripping onto food, equipment, utensils, linens, and single-service and single-use articles.
Item No.: 33
Site: Other-PARROT'S CAY GALLEY
Violation: THE DECK BENEATH TECHNICAL AREA # 267 WAS SOILED WITH POOLED LIQUID AND PIECES OF SATURATED PIPE INSULATION.
Recommendation: 7.7.4.2.1 Decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, shall be cleaned as often as necessary.
Item No.: 20
Site: Other-CREW MESS-BUFFET LINE
Violation: CORROSION WAS NOTED IN THE CUBER AREA OF THE ICE MACHINE.
Recommendation: 7.4.1.1.2 Materials that are used in the construction of multiuse utensils and food-contact surfaces of equipment shall be: (1) Durable, corrosion-resistant, and nonabsorbent; (2) Sufficient in weight and thickness to withstand repeated warewashing; (3) Finished to have a smooth, easily cleanable surface; and (4) Resistant to pitting, chipping, crazing, scratching, scoring, distortion, and decomposition.
Item No.: 19
Site: Other-CREW MESS-BUFFET LINE
Violation: THE SNEEZE SHIELDS DID NOT HAVE SIDE PANELS TO PROTECT THE FOOD STORED BENEATH.
Recommendation: 7.3.3.6.1 Food on display shall be protected from contamination by the use of packaging; counter, service line, or salad bar food guards; display cases; or other effective means.
Item No.: 33
Site: Other-PROVISIONS
Violation: PEELING SEALANT WAS NOTED ON THE DECKHEAD OF THE FISH FREEZER.
Recommendation: 7.7.4.1.1 Decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas shall be constructed and maintained for easy cleaning.
Item No.: 26
Site: Other-BUFFET PREPARATION ROOM
Violation: THE BACK GUARD OF THE SLICER WAS SOILED.
Recommendation: 7.3.3.4.1 Food shall only contact surfaces of equipment and utensils that are cleaned and sanitized.
Item No.: 08
Site: Other-MEDICAL
Violation: THE X-RAY DEVELOPER DID NOT APPEAR TO HAVE A BACKFLOW PREVENTION DEVICE ON THE POTABLE WATER INLET LINE.
Recommendation: 5.7.1.2.6 Backflow preventers shall be provided on all fixtures using potable water and which have submerged inlets. Assure that the device installed is approved for this application.
Item No.: 33
Site: Other-FOOD SERVICE GENERAL
Violation: CORROSION WAS NOTED IN NUMEROUS SCUPPERS THROUGHOUT THE FOOD SERVICE AREAS AND THE DECKING WAS IN DISREPAIR IN A FEW AREAS.
Recommendation: 7.7.4.1.1 Decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas shall be constructed and maintained for easy cleaning.
Item No.: 03
Site: Other-POTABLE WATER
Violation: ON 3/13/04 AND 3/20/04 THE ANALYZER-CHART RECORDER CHARTS INDICATED THAT POTABLE WATER WAS BUNKERED BELOW 2.0 PPM FOR SEVERAL HOURS EACH DAY. THE ENGINEER STATED THAT SOMETIMES PROBLEMS WITH WATER FLOW CAN CAUSE THE CHLORINE LEVEL TO DROP BELOW 2.0 PPM.
Recommendation: 5.2.1.1.1 Potable water shall be continuously halogenated to at least 2.0 mg/L (ppm) free residual halogen at the time of bunkering or production with an automatic halogenation device.
Item No.: 29
Site: Other-TOPSIDERS BUFFET
Violation: A HANDWASHING FACILITY WAS NOT LOCATED WITHIN 8 METERS (25 FEET) OF THE CARVING STATIONS ON THE BUFFET LINES.
Recommendation: 7.7.1.1.1 Each food preparation area, bar, warewashing area, and garbage-processing area shall have at least one handwashing facility located in it. 7.7.1.1.2 The handwashing facility shall be located within 8 m (25 feet) of all parts of the area and should not be located in an adjacent area that requires passage through a closed door.
Item No.: 20
Site: Other-DECK 9 COFFEE STATION
Violation: THE BULK MILK CONTAINER DISPENSING TUBES WERE NOT CUT AT AN ANGLE.
Recommendation: 7.4.5.3.2 The bulk milk container dispensing tube shall be cut on the diagonal leaving no more than 3 centimeters (1 inch) protruding from the chilled dispensing head.
Item No.: 20
Site: Other-DECK 9 COFFEE STATION
Violation: AN ABSORBENT GASKET WAS NOTED BETWEEN THE UPPER AND LOWER COMPARTMENTS OF THE ICE MACHINE. THIS GASKET WAS RETAINING WATER.
Recommendation: 7.4.1.1.2 Materials that are used in the construction of multiuse utensils and food-contact surfaces of equipment shall be: (1) Durable, corrosion-resistant, and nonabsorbent; (2) Sufficient in weight and thickness to withstand repeated warewashing; (3) Finished to have a smooth, easily cleanable surface; and (4) Resistant to pitting, chipping, crazing, scratching, scoring, distortion, and decomposition.
Item No.: 26
Site: Other-PLUTO'S DOGHOUSE PANTRY
Violation: A COPPER FITTING WAS NOTED BETWEEN THE BACKFLOW PREVENTION DEVICE AND THE CARBONATOR. THIS WAS REPAIRED DURING THE INSPECTION.
Recommendation: 7.4.1.1.5 Copper and copper alloys such as brass: (1) May not be used in contact with a food that has a pH below 6 such as vinegar, fruit juice, or wine or for a fitting or tubing installed between a backflow prevention device and a carbonator.
Item No.: *
Site: Other-CORRECTIVE ACTION STATEMENT
Violation: IN DEVELOPING THE CORRECTIVE ACTION STATEMENT FOR THIS INSPECTION, CRITICAL-ITEM DEFICIENCIES (DESIGNATED WITH YES IN CRITICAL COLUMN (WORTH 3 - 5 POINTS), WHETHER DEBITED OR NOT, SHOULD INCLUDE STANDARD OPERATING PROCEDURES AND MONITORING PROCEDURES IMPLEMENTED TO PREVENT THE RECURRENCE OF THE CRITICAL DEFICIENCY. PREPARE CORRECTIVE ACTION STATEMENT AS A WORD PROCESSING OR SPREADSHEET FILE WHICH WILL BE SENT TO USPHS / VSP AS AN EMAIL MESSAGE ATTACHMENT. PLEASE EMAIL CORRECTIVE ACTION STATEMENT TO: VSP@CDC.GOV USE EMAIL MESSAGE SUBJECT LINE: SHIP NAME: DISNEY MAGIC - CAS - [INSPECTION DATE: 06/05/2004] .
Recommendation:
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program