Skip directly to site content Skip directly to page options

Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: Celebrity Eclipse Cruise Line: Celebrity Cruises Inspection Date: 11/15/2015 Inspection Score: 99
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 19
Site: Buffet-Ocean View Cafe
Violation: The handle of a serving spoon was in direct contact with herring. This was corrected.
Recommendation: During pauses in food preparation or dispensing, ensure food preparation and dispensing utensils are stored: (1) In the food with their handles above the top of the food and the container; (2) In food that is not potentially hazardous with their handles above the top of the food within containers or equipment that can be closed, such as bins of sugar, flour, or cinnamon; (3) On a clean portion of the food preparation table or cooking equipment only if the in-use utensil and the food-contact surface of the food preparation table or cooking equipment are cleaned and sanitized at least every 4 hours; (4) In running water of sufficient velocity to flush particulates to the drain (if used with moist food such as ice cream or mashed potatoes); (5) In a clean, protected location (if the utensils, such as ice scoops, are used only with a food that is not potentially hazardous); or (6) In a container of water (if the water is maintained at a temperature of at least 57C [135F] and the container is frequently cleaned and sanitized).
Item No.: 16
Site: Buffet-Ocean View Cafe
Violation: The consumer advisory for the pickled herring and cold smoked salmon had the correct consumer advisory statement, but there was no statement indicating that the fish items were served raw/undercooked. This was corrected during the inspection.
Recommendation: If an animal food such as beef, eggs, fish, lamb, milk, pork, poultry, or shellfish that is raw, undercooked, or not otherwise processed to eliminate pathogens is offered in a ready-to-eat form or as a raw ingredient in another ready-to-eat food, ensure the consumer is informed by way of disclosure using menu advisories, placards, or other easily visible written means of the significantly increased risk to certain especially vulnerable consumers eating such foods in raw or undercooked form. Locate the advisory at the outlets where these types of food are served. Ensure that disclosure is made: (1) On a sign describing the animal-derived foods (e.g., "oysters on the half-shell," "hamburgers," "steaks," or "eggs"); AND that they can be cooked to order and may be served raw or undercooked; AND a statement indicating that consuming raw or undercooked meats, seafood, shellfish, eggs, milk, poultry may increase your risk for foodborne illness, especially if you have certain medical conditions. Ensure the advisory is posted at the specific station where the food is served raw, undercooked, or cooked to order.
Item No.: 19
Site: Buffet-Tuscan Grille
Violation: The portable sneeze guard on the self-service breakfast buffet did not have a side shield at the beginning to protect the food within one meter of where consumers were expected to stand.
Recommendation: Protect food on display from contamination by the use of packaging; counter, service line, or salad bar food guards; display cases; self-closing hinged lids; or other effective means. Install side protection for sneeze guards if the distance between exposed food and where consumers are expected to stand is less than 1 meter (40 inches).
Item No.: 16
Site: Buffet-Tuscan Grille
Violation: The consumer advisory for the cold smoked salmon had the correct consumer advisory statement, but there was no statement indicating that the fish items were served raw/undercooked. This was corrected during the inspection.
Recommendation: If an animal food such as beef, eggs, fish, lamb, milk, pork, poultry, or shellfish that is raw, undercooked, or not otherwise processed to eliminate pathogens is offered in a ready-to-eat form or as a raw ingredient in another ready-to-eat food, ensure the consumer is informed by way of disclosure using menu advisories, placards, or other easily visible written means of the significantly increased risk to certain especially vulnerable consumers eating such foods in raw or undercooked form. Locate the advisory at the outlets where these types of food are served. Ensure that disclosure is made: (1) On a sign describing the animal-derived foods (e.g., ?oysters on the half-shell,? ?hamburgers,? ?steaks,? or ?eggs?); AND that they can be cooked to order and may be served raw or undercooked; AND a statement indicating that consuming raw or undercooked meats, seafood, shellfish, eggs, milk, poultry may increase your risk for foodborne illness, especially if you have certain medical conditions. Ensure the advisory is posted at the specific station where the food is served raw, undercooked, or cooked to order.
Item No.: 22
Site: Galley-Murano
Violation: The left hand nozzle on the upper final rinse spray arm was not spraying in a full fan spray pattern. The nozzle was replaced immediately.
Recommendation: Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines.
Item No.: 26
Site: Galley-Deck 3 Coffee Station
Violation: Residue was inside the previously cleaned milk tube for the coffee machine. This was corrected.
Recommendation: Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 32
Site: Galley-Deck 3 Hot Galley
Violation: A large plastic waste bin with food waste was stored in this area without a cover. The area was not in operation while the inspection team was in the area. The bin was removed immediately.
Recommendation: Cover receptacles and waste-handling containers when not in continuous use and after they are filled.
Item No.: 08
Site: Potable Water-Tank Maintenance
Violation: The 8 potable water tank (3 port & starboard, 4 port & starboard, 5 port & starboard, 7 port & starboard) maintenance records from March-November 2015 did not document the free halogen residual level to verify the level was below 5.0 ppm before placing the tanks back into service.
Recommendation: Flush the disinfected parts of the system with potable water or otherwise dechlorinate until the free residual halogen is less than or equal to 5.00 mg/L (ppm). Document the free halogen test result. Document the free halogen residual level.
Item No.: 08
Site: Potable Water-Technical Water Filling Deck 2, Fire Zone 6
Violation: The air gap was modified with a metal covering, and was no longer an air gap. This cover was removed.
Recommendation: Ensure air gaps are at least twice the diameter of the delivery fixture opening and a minimum of 25 millimeters (1 inch).
Item No.: 10
Site: Recreational Water Facilities-Pool Monitoring Analyzer Sample Lines
Violation: The sample line for the monitoring analyzer probe included water directly from the facility, as well as water from the buffer tank. This was the design for all pools to include Lap Pool, Family Pool, and Sports Pool.
Recommendation: Ensure the sample line for the analyzer probe (monitoring) is either directly from the RWF or on the return line from each RWF and before the compensation tank.
Item No.: 22
Site: Galley-Deck 2 Hot Galley
Violation: The sanitizing solution in the three bucket cleaning system near the handwash sink between the potwash entry and hot galley was soiled with food oil. The solution was changed.
Recommendation: Ensure the sanitize solutions are maintained clean.
Item No.: 21
Site: Buffet-Deck 2 - Crew Mess
Violation: The bulk milk dispenser door gasket was not mounted correctly creating gaps the door closure. No milk was stored in the unit at the time of the finding. Crew started reinstalling the gasket immediately.
Recommendation: Ensure nonfood contact equipment is maintained in good repair and proper adjustment including: (2) Equipment components such as seals are kept intact, tight, and adjusted in accordance with manufacturer's specifications.
Item No.: 26
Site: Buffet-Deck 2 - Crew Mess
Violation: The counter mounted cubed ice machine had several food contact and splash area surfaces soiled. The white plastic housing above the ice dispenser control plate had dust on its outer surface immediately above where the ice is discharged into the glass. The white plastic collar where the ice is discharged from the ice maker into the holding bin was soiled with a small amount of mold. The ice machine was taken out of service and cleaned.
Recommendation: Ensure food contact surfaces and food splash areas of equipment are clean to sight and touch.
Item No.: 27
Site: Preparation Room-Deck 2 - Bulk Vegetable Processing
Violation: The lettuce dryer that was stored as clean had a piece of lettuce in the basket mounting support.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of food residue.
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program