Skip directly to site content Skip directly to page options

Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: Carnival Sunrise Cruise Line: Carnival Cruise Lines, Inc. Inspection Date: 12/03/2005 Inspection Score: 97
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 02
Site: Medical-MEDICAL
Violation: THE MEDICAL DEPARTMENT DID NOT HAVE THE CLINICAL SPECIMEN CONTAINERS OR THE APPROPRIATE LABELS AND PACKAGING FOR BOTH VIRAL AND BACTERIAL SPECIMENS. THIS IS A NEW 2005 VSP REQUIREMENT.
Recommendation: Ensure the medical staff maintains a supply of at least 10 clinical specimen collection containers for both viral and bacterial agents ( 10 for each), as well as the proper shipping containers and labels for the same and provided in Annex 13.4 of this manual.
Item No.: 21
Site: Food Service General-BARS AND MAIN GALLEY
Violation: AN OPEN CELL INSULATING MATERIAL WAS NOTED ON THE FRONT PLASTIC COVER FOR THE WATER/ICE FALL AREA IN SOME OF THE CORNELIUS ICE MACHINES, LOCATED IN VARIOUS FOOD PREPARATION AREAS.
Recommendation: Ensure that nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material.
Item No.: 26
Site: Galley-GARDE MANGER
Violation: THE AREA UNDERNEATH THE MIXER COLLAR WAS SOILED WITH A GREASY FOOD RESIDUE.
Recommendation: Ensure that food-contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 21
Site: Food Service General-MAIN AND CREW GALLEY
Violation: NUMEROUS DOORS FOR THE UNDERCOUNTER REFRIGERATION UNITS WERE NOT TIGHT FITTING. THE BOTTOMS OF THESE DOORS DID NOT SEAL WELL.
Recommendation: Ensure that nonfood-contact equipment components such as doors, seals, hinges, fasteners, and kick plates are kept intact, tight, and adjusted in accordance with manufacturer's specifications.
Item No.: 21
Site: Galley-MAIN GALLEY - HOT SERVICE LINE
Violation: EXCESSIVE SEALANT WAS NOTED IN THE NON-FOOD CONTACT SURFACES OF THE FRYERS LOCATED ON THE FORWARD HOT SERVICE LINE, MAKING CLEANING DIFFICULT.
Recommendation: Ensure that nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material.
Item No.: 21
Site: Food Service General-
Violation: A THIN GRADE OF ALUMINUM FOIL WAS USED TO WRAP THE PIPES AROUND KETTLES AND TILT PANS. THE FOIL WRAPPING WAS LOOSE AND DIFFICULT TO CLEAN.
Recommendation: Ensure that nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material. Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 37
Site: Other-ROOM SERVICE PANTRY
Violation: THE ROOM SERVICE PANTRY WAS NOTABLY HOT AND HUMID.
Recommendation: Ensure that all food preparation, warewashing, and toilet rooms have sufficient ventilation to keep them free of excessive heat, steam, condensation, vapors, obnoxious odors, smoke, and fumes.
Item No.: 34
Site: Galley-PASTRY ROOM 30 - FREEZER CONDENSATE DRAIN
Violation: A SIGNIFICANT ICE BUILD-UP WAS NOTED AROUND THE DRAIN AND WITHIN THE CONDENSATE DRAIN PAN OF THE COOLING UNIT LOCATED IN THE PASTRY ROOM FREEZER.
Recommendation: Repair or replace the heat tape for the cool unit in pastry room 30.
Item No.: 33
Site: Galley-FORWARD DISHWASH AREA
Violation: AN EXCESSIVE AMOUNT OF WATER WAS NOTED ON THE DECK.
Recommendation: Squeegee the water to a deck drain.
Item No.: 22
Site: Pantry-ACROSS FROM ROOMS 10-61 & 9-269
Violation: THERE WAS NO DATA PLATE ON THE DISHWASHERS.
Recommendation: Ensure that warewashing machines are provided with an easily accessible and readable data plate affixed to the machine by the manufacturer that indicates the machine's design and operating specifications including the: (1) Temperatures required for washing, rinsing, and sanitizing; (2) Pressure required for the fresh water sanitizing rinse; and (3) Conveyor speed for conveyor machines or cycle time for stationary rack machines.
Item No.: 20
Site: Pantry-ACROSS FROM ROOM 8-260
Violation: SLOTTED FASTENERS WERE NOTED UNDER THE CUBER IN THE UPPER COMPARTMENT OF THE ICE MACHINE.
Recommendation: Remove the slotted fasteners and replace them with smooth low profile non slotted fasteners.
Item No.: 27
Site: Buffet-GRAND BUFFET, PORT SIDE
Violation: THE THERMOMETER AND THE RIGHT WALL OF THE PLATE WARMER COMPARTMENT UNDER THE BUFFET WERE SOILED WITH A DARK FILM.
Recommendation: Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 26
Site: Galley-CONEY ISLAND GRILL
Violation: THE INTERIOR OF THE CTX WAS SOILED WITH FOOD DEBRIS. THE STAFF STATED THE CTX IS NOT USED.
Recommendation: Ensure that food-contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 38
Site: Galley-CONEY ISLAND GRILL
Violation: THE STAFF STATED THAT THE CTX IS NOT USED.
Recommendation: Remove the CTX unit if there are no plans for its use.
Item No.: 06
Site: Potable Water-
Violation: DAILY CALIBRATION OF THE FAR POINT ANALYZER/CHART RECORDER WAS NOT RECORDED BETWEEN 14 AUGUST AND 1 DECEMBER 2005. ALSO, THE CHARTS FOR 29 AND 30 SEPTEMBER WERE NOT DATED AND BETWEEN 13 AND 26 OCTOBER, THERE WERE 8 UNDATED AND 3 MISSING CHARTS.
Recommendation: Ensure that the halogen analyzer-chart recorder is properly maintained, operated, and calibrated daily in accordance with the manufacturer's instructions.
Item No.: 08
Site: Potable Water-
Violation: THERE WAS NO DOCUMENTATION OF THE RECOMMENDATIONS FOLLOWED FOR DRYING/CURING OF COATINGS USED IN THE POTABLE WATER TANKS. THIS IS A NEW REQUIREMENT OF THE 2005 VSP OPERATIONS MANUAL.
Recommendation: Ensure that interior coatings on potable water tanks are approved for potable water contact.
Item No.: 08
Site: Potable Water-
Violation: THERE WAS NO DOCUMENTATION THAT THE POTABLE WATER TANKS WERE FLUSHED TO BELOW 5 PPM BEFORE PLACING THEM BACK INTO SERVICE FOLLOWING DISINFECTION.
Recommendation: Ensure that the disinfected parts of the system are flushed with potable water until the free residual halogen is 5.00 mg/L (ppm).
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program