Skip directly to site content Skip directly to page options

Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: MSC Lirica Cruise Line: MSC Cruise Management (UK) Ltd Inspection Date: 01/06/2009 Inspection Score: 100
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 10
Site: Recreational Water Facilities-Deck 11 Aft Pool
Violation: There was one screw missing from each of the two main drain covers.
Recommendation: Ensure all drain cover fasteners are installed properly.
Item No.: 08
Site: Potable Water-Cross-Connection Control Program
Violation: The listing of cross connections did not include the air gaps for the mineralizer, water softener, or evaporator drains.
Recommendation: Ensure that air-gaps are included in the cross-connection control program listing.
Item No.: 21
Site: Bar-Deck 11 Pool Bar - Technical Space Below Espresso Machine
Violation: There was a void space between the storage cabinet insert and the floor of the technical space located below the espresso machine.. The void space was sealed at the time of the inspection.
Recommendation: Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 08
Site: Potable Water-Cross-Connection Control Program
Violation: The cross-connection listing for the passenger and crew showers/toilets did not list the type of backflow prevention device/method used.
Recommendation: Ensure that the cross-connection control program listing includes the backflow prevention method/device for each (non-continuous pressure type, continuous pressure type, atmospheric vacuum breaker, etc.), so that there is a match to the plumbing system component and location.
Item No.: 21
Site: Galley-LeBistrot Dishwash Area
Violation: Some of the large, black waiter trays were damaged along the edges.
Recommendation: Replace damaged waiter trays.
Item No.: 26
Site: Galley-LeBistrot Dishwash Area
Violation: Two previously cleaned cold cut trays, one fork and two medium-sized salad bowls were found soiled and stored as clean.
Recommendation: Ensure that food only contacts surfaces of equipment and utensils that are cleaned and sanitized.
Item No.: 21
Site: Buffet-LeBistrot Beverage Stations (Port/Starboard)
Violation: A void space was noted in the technical compartment of both beverage stations. The void was clean at the time of the finding. This was corrected.
Recommendation: Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 20
Site: Buffet-La Pergola Beverage Station (Starboard)
Violation: The bulk milk dispenser tube was not cut at an angle to allow the milk tube to drain.
Recommendation: Ensure that the bulk milk container dispensing tube is cut on the diagonal leaving no more than 25mm (1 inch) protruding from the chilled dispensing head.
Item No.: 26
Site: Galley-Potwash Area
Violation: One previously cleaned spatula was found soiled and stored ready for use. This was corrected.
Recommendation: Ensure that food only contacts surfaces of equipment and utensils that are cleaned and sanitized.
Item No.: 21
Site: Galley-Potwash Area
Violation: The data plate on the mechanical pot washer was peeling.
Recommendation: Replace the data plate.
Item No.: 33
Site: Galley-Potwash Area
Violation: There was peeling sealant on the bulkhead near the handwash station and the clean storage rack. This was corrected.
Recommendation: Remove sealant.
Item No.: 33
Site: Galley-Soup Station
Violation: There was peeling sealant on the bulkhead behind the combination oven and adjacent to the exit door.
Recommendation: Remove sealant and re-seal seam as needed.
Item No.: 21
Site: Galley-Hot Galley
Violation: There were peeling labels on the portside control panel of the grills.
Recommendation: Replace labels as needed.
Item No.: 21
Site: Galley-Dishwash Area
Violation: A few waiter trays were damaged along the edges. This was corrected.
Recommendation: Discard damaged waiter trays.
Item No.: 33
Site: Pantry-Room Service Pantry
Violation: There was peeling sealant on the bulkhead under the single-compartment dishwasher. This was corrected.
Recommendation: Remove sealant and re-seal seam as needed.
Item No.: 27
Site: Galley-Deep Fat Fryer
Violation: There was a small amount of grease on the exterior surface of the previously cleaned deep fat fryer technical area.
Recommendation: Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 27
Site: Galley-Ribbed Grill
Violation: There was some encrusted food debris in the grease tray housing of this unit.
Recommendation: Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 21
Site: Galley-Deep Fat Fryer
Violation: A peeling label was found on the this unit. This was corrected.
Recommendation: Replace label as needed.
Item No.: 10
Site: Recreational Water Facilities-Passenger and Crew Pools
Violation: The drain covers were not stamped with an approving organization or flow rate information. The documentation received from the yard stated that the covers were "anti-vortex", however the cited references were for construction materials.
Recommendation: Ensure that the drain covers have either the plumbing/engineering approving organization stamp and flow rate affixed to the cover, or that a letter is maintained aboard the vessel certifying that the cover meets the safety requirements outlined in AMSE/ANSI A112.19.8M or an equivalent standard.
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program