Item No.:
33
|
|
Site:
Galley-Deck 3 Hot Galley
|
|
Violation:
An open pipe penetration was noted behind the middle tilting pan in the hot galley area.
|
|
Recommendation:
Seal the open pipe penetration.
|
|
|
Item No.:
19
|
|
Site:
Other-Hydro Pool
|
|
Violation:
One bowl of apples was set out for service in the pool area and not placed under a sneeze guard.
|
|
Recommendation:
Ensure that food on display is protected from contamination by the use of packaging; counter, service line, or salad bar food guards; display cases; or other effective means.
|
|
|
Item No.:
19
|
|
Site:
Other-Hydro Pool
|
|
Violation:
Serving utensils were not available for the bowl of apples in this area.
|
|
Recommendation:
Provide serving utensils for the apples.
|
|
|
Item No.:
28
|
|
Site:
Other-Hydro Pool Area
|
|
Violation:
A few plastic glasses were wet stacked and placed out for service.
|
|
Recommendation:
After cleaning and sanitizing, ensure that equipment and utensils are air-dried or adequately drained before contact with food.
|
|
|
Item No.:
19
|
|
Site:
Buffet-Bistro Area
|
|
Violation:
Heavy condensation was noted under the sneeze guard on the service line. Food was placed out for service under the guard. Water was not observed dripping onto food items. The water temperature was turned down at the bain marie units during the inspection and the area was dried.
|
|
Recommendation:
Reduce the water temperature of the bain marie units to ensure condensation does not collect under the sneeze guards.
|
|
|
Item No.:
19
|
|
Site:
Buffet-Sushi Bar
|
|
Violation:
Heavy condensation was noted under the sneeze guard on the service line. Food was placed out for service under the guard. Water was observed dripping onto food items. The water temperature was turned down at the bain marie units during the inspection and the area was dried. This was noted around 0900 and 1300.
|
|
Recommendation:
Reduce the water temperature of the bain marie units to ensure condensation does not collect under the sneeze guards and drip onto the food.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Bunker Station
|
|
Violation:
The starboard side sea water connection point was painted the same blue color as the potable water connection. These connections are located next to each other.
|
|
Recommendation:
Paint the starboard side sea water connection point another color appropriate for its use.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-
|
|
Violation:
The reduced pressure backflow prevention devices for the high saline discharge of evaporators one, two and three were not inspected on an annual basis. These devices are not listed on the testable backflow inspection sheet. Staff stated that these devices had not been tested.
|
|
Recommendation:
Ensure that backflow prevention devices requiring testing, for example reduced pressure backflow preventer and double check valves with test cocks, are inspected and tested with a test kit at least annually and that the test results showing the pressure differences on both sides of the valves are maintained for each device.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Spa
|
|
Violation:
It was unclear if a backflow protection device was located on the two pedicure machines. A device type for these machines was not listed in the cross-connection control program.
|
|
Recommendation:
Ensure the pedicure machines are listed on the cross-connection control program.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-
|
|
Violation:
The reduced pressure backflow devices for the hood cleaning systems were not tested on an annual basis. These devices were not listed on the testable backflow sheet.
|
|
Recommendation:
Ensure that backflow prevention devices requiring testing, for example reduced pressure backflow preventer and double check valves with test cocks, are inspected and tested with a test kit at least annually and that the test results showing the pressure differences on both sides of the valves are maintained for each device.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-
|
|
Violation:
Documentation of the inspection, maintenance, cleaning, disinfection and flushing of the number one starboard side potable water tank was not available for review. Staff stated that the above items were conducted on the tank, however a record was not maintained. Documentation of the inspection, maintenance, cleaning and disinfection of the other potable water tanks were maintained, however there was no documentation of the flushing or indication that the tanks measured less than 5 ppm before being placed back into service.
|
|
Recommendation:
Ensure that the disinfected parts of the system are flushed with potable water until the free residual halogen is at or below 5.00 mg/L (ppm). Ensure that documentation of any inspection, cleaning, disinfection (including concentration and contact time of disinfectant), and flushing is maintained for 12 months and is available to the VSP for review during inspections.
|
|
|
Item No.:
19
|
|
Site:
Buffet-Starboard Side Aft
|
|
Violation:
One tray of salad dressing was placed out for passenger self service and not under a sneeze guard. This was corrected.
|
|
Recommendation:
Ensure that food on display is protected from contamination by the use of packaging; counter, service line, or salad bar food guards; display cases; or other effective means.
|
|
|
Item No.:
28
|
|
Site:
Buffet-Lido Dishwash
|
|
Violation:
Staff was observed drying damp bowls with a cloth as they exited the dishwash machine.
|
|
Recommendation:
After cleaning and sanitizing, ensure that equipment and utensils are air-dried or adequately drained before contact with food.
|
|
|
Item No.:
22
|
|
Site:
Buffet-Lido Dishwash
|
|
Violation:
A data plate was not located on the glasswash machine.
|
|
Recommendation:
Ensure that warewashing machines are provided with an easily accessible and readable data plate affixed to the machine by the manufacturer that indicates the machine's design and operating specifications including the: (1) Temperatures required for washing, rinsing, and sanitizing; (2) Pressure required for the fresh water sanitizing rinse; and (3) Conveyor speed for conveyor machines or cycle time for stationary rack machines.
|
|
|
Item No.:
19
|
|
Site:
Pantry-Deck 8
|
|
Violation:
The ice machine door was left open in pantry 8.5.0.1. The pantry door was also open and the ice machine was located near the door. Crew was not observed working in this area.
|
|
Recommendation:
Ensure that food is protected from contamination by storing the food: (1) In a clean, dry location; (2) Where it is not exposed to splash, dust, or other contamination; and (3) At least 15 centimeters (6 inches) above the deck.
|
|