Cruise Ship: Queen Mary 2 Cruise Line: Carnival UK LTD Inspection Date: 01/20/2008 Inspection Score: 100
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 08
Site: DO NOT USE (whirlpool/spa)-Mechanical Rooms
Violation: The potable water filling lines for the whirlpools were striped blue after the backflow prevention device.
Recommendation: Remove blue striping from potable water line after the backflow prevention device.
Item No.: 08
Site: Potable Water-Deck 6 - Laundry Room Aft.
Violation: The backflow device on the cold potable water supply line was leaking.
Recommendation: Repair or replace the leaking backflow prevention device.
Item No.: 34
Site: Galley-Steam Kettles
Violation: There was a leak at the bottom of the technical compartment for the steam kettles in the main and crew galleys.
Recommendation: Ensure that a plumbing system in a food area is maintained in good repair.
Item No.: 37
Site: Galley-Soup Station
Violation: There was a condensate drip from the overhang above the kettles onto the deck. The kettles were located across from the mixer.
Recommendation: Ensure that ventilation hood systems and devices are sufficient in number and capacity to prevent grease or condensation from collecting on bulkheads and deckheads.
Item No.: 27
Site: Galley-Garde Manger
Violation: There was dried food debris on the non-food contact surfaces of the previously cleaned meat slicer.
Recommendation: Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 20
Site: Galley-Port Hot Galley
Violation: There were slotted fasteners inside the deep fat fryer, making cleaning difficult.
Recommendation: Replace slotted fasteners with low profile, smooth fasteners.
Item No.: 08
Site: Galley-Starboard Coffee Station
Violation: There was a leak at the vent of the backflow prevention device for the juice machine.
Recommendation: Repair or replace the leaking backflow prevention device.
Item No.: 21
Site: Galley-Port Coffee Station
Violation: There was a leak at the bottom right corner of the bulk milk dispenser.
Recommendation: Repair the leaking bulk milk dispenser.
Item No.: 33
Site: Other-Britannia Dining Room
Violation: The deck/cabinet juncture was not coved at a few waiter stations, making cleaning difficult.
Recommendation: Ensure that bulkhead and deck junctures are coved (including galleys, pantries, deck/counter junctures at buffets, bars, waiter stations, and dining room work counters).
Item No.: 37
Site: Galley-
Violation: There was an excessive amount of condensate forming on the deckhead above the combination oven. The condensate was dripping onto the deck.
Recommendation: Ensure that ventilation hood systems and devices are sufficient in number and capacity to prevent grease or condensation from collecting on bulkheads and deckheads.
Item No.: 33
Site: Buffet-Officer's Mess
Violation: The coving was loose at the waiter station, making cleaning difficult.
Recommendation: Repair the loose coving.
Item No.: 19
Site: Buffet-Officer's Mess
Violation: The soup kettle was not located under a sneeze guard. The kettle was removed.
Recommendation: Place soup kettles under sneeze guards when placed out for service.
Item No.: 34
Site: Preparation Room-Fish Preparation Room
Violation: There was a leak at the faucet of the preparation sinks.
Recommendation: Ensure that a plumbing system in a food area is maintained in good repair.
Item No.: 20
Site: Pantry-Casino Bar
Violation: There were slotted fasteners inside the ice bath compartment of the ice machine. The slots were filled with an excessive amount of sealant, making cleaning difficult.
Recommendation: Replace slotted fasteners with low profile, smooth fasteners.
Item No.: 10
Site: Housekeeping-Suite Whirlpools
Violation: The records indicated that some whirlpools were being cleaned every seven days and between passenger turnover. However, other whirlpools were only being cleaned between passenger turnover. The current itinerary is a ten day cruise.
Recommendation: Ensure that private whirlpool spas located in individual passenger cabins are cleaned and disinfected, including associated recirculation systems, between occupancies or weekly, whichever is more frequent.
Item No.: 26
Site: Galley-Lido - La Piazza
Violation: One previously cleaned stainless steel lid was found soiled and stored as clean. This item was corrected during the inspection.
Recommendation: Ensure that food-contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 36
Site: Galley-Lido -Chef's Galley
Violation: The coating on the light bulb of the heat lamp at the carving station was separating from the bulb surface, making cleaning difficult.
Recommendation: Replace bulb or repair bulb coating.
Item No.: 25
Site: Galley-Lido - Lotus Coffee Station
Violation: A wet wiping cloth was found on the countertop beneath the large coffee machine.
Recommendation: Ensure that wiping cloths used for wiping food spills are dry and used for wiping food spills from tableware and single-service articles; or wet and cleaned, stored in a chemical sanitizer, and used for wiping spills from food-contact and nonfood-contact surfaces of equipment.
Item No.: 34
Site: Galley-Lido - Lotus Coffee Station
Violation: The plastic flexible drain line from the coffee machine extended to the bottom of the scupper.
Recommendation: Cut the drain line so that it does not extend to the bottom of the scupper.
Item No.: 26
Site: Buffet-Lido - Lotus Fruit Buffet
Violation: A few soiled utensils were found in the dispensers ready for service.
Recommendation: Ensure that food-contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 19
Site: Buffet-Lido - Lotus Cold Station
Violation: Dried fruits and nuts were placed on the buffet line without shielding or otherwise protected. Utensils were provided for each item placed out for self-service. A monitor was staged across from the buffet line. Two passengers were observed obtaining food items with their bare hands. These items were discarded immediately.
Recommendation: Ensure that food on display is protected from contamination by the use of packaging; counter, service line, or salad bar food guards; display cases; or other effective means.
Item No.: 26
Site: Buffet-Lido - Carvery
Violation: A few utensils were found soiled and stored ready for service. This item was corrected during the inspection.
Recommendation: Ensure that food-contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 21
Site: Galley-Todd English
Violation: A gap was noted in the side panel of the technical compartment below Grill 2.2, making cleaning difficult.
Recommendation: Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.