Cruise Ship: Norwegian Pearl Cruise Line: Norwegian Cruise Lines Inspection Date: 05/04/2015 Inspection Score: 97
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 02
Site: Medical-Acute Gastroenteritis (AGE)
Violation: On the cruise from 16 April to 2 May, a passenger with 20 episodes of diarrhea was incorrectly identified as a crew member.
Recommendation: Ensure the AGE surveillance log entry for each passenger or crew member contain the following information in separate columns: (1) Date of the first medical visit or report to staff of illness; (2) time of the first medical visit or report to staff of illness; (3) case identification number; (4) person?s name; (5) person?s age; (6) person?s sex; (7) designation as passenger or crew member; (8) crew member position or job on the vessel, if applicable; (9) cabin number; (10) meal seating information; (11) date of illness onset; (12) time of illness onset; (13) illness symptoms, including the presence or absence of the following selected signs and symptoms, with a separate column for each of the following: (a) number of episodes of diarrhea in a 24-hour period; (b) number of episodes of vomiting in a 24-hour period; (c) bloody stools; (d) recorded temperature; (e) abdominal cramps; (f) headaches; (g) muscle aches; (14) entry (yes/no) for whether this was a reportable case; (15) entry (yes/no) for antidiarrheal medications sold or dispensed by designated medical staff; (16) presence of underlying medical conditions that may affect interpretation of AGE. Ensure the AGE surveillance log contains the above information in the exact order and is entered in the template in Annex 13.2.2. Ensure that the log data is exported in the exact order as in the example template in Annex 13.2.2 with analyzable formats such as Excel or Access. Ensure that any additional data fields are entered only outside of the form margins when exported to VSP.
Item No.: 08
Site: Galley-Bistro Dishwash Area
Violation: Next to the hood-type dishwash machine, the prerinse hose backflow prevention device vent was continuously leaking.
Recommendation: Maintain backflow prevention devices in good repair. Inspect backflow prevention devices periodically and replace any failed units.
Item No.: 08
Site: Galley-Hot Galley Soup Station
Violation: The vent on the vertically installed backflow prevention device on combination oven 551.205.00 was sloped up instead of horizontal or down. The bracket for the bulkhead-water filter was missing a fastner, which caused the entire assembly, including the backflow prevention device to be out of place. The fastener was replaced and the vent on the device was returned to the proper position.
Recommendation: Maintain backflow prevention devices in good repair. Inspect backflow prevention devices periodically and replace any failed units.
Item No.: 10
Site: Recreational Water Facilities-Hydrothreapy Pool
Violation: The water in this pool was deeper that 36 inches (one meter) and did not have depth markers.
Recommendation: Prominently display the depth of each RWF that is deeper than 1 meter (3 feet) so that it can be seen from the deck and in the pool. Label depth markers in both feet and meters. Additionally, install depth markers for every 1 meter (3 feet) change in depth.
Item No.: 11
Site: Medical-Late Reporting
Violation: On the cruise from 6 April to 16 April, a non-food handler stated AGE symptom onset was at 0200 31 Mar and reported to medical at 0730 31 Mar. The crew member remained in their cabin during that time. The crew member received disciplinary action.
Recommendation: When food employees meet the case definition for AGE, ensure the following actions are taken: (1) isolate in cabin or designated restricted area until symptom-free for a minimum of 48 hours; (2) follow-up with and receive approval by designated medical personnel before returning crew to work; (3) document date and time of last symptom and clearance to return to work. When nonfood employees meet the case definition for AGE, ensure the following actions are taken: (1) isolate in cabin or designated restricted area until symptom-free for a minimum of 24 hours; (2) follow-up with and receive approval by designated medical personnel before returning crew to work; (3) document the date and time of last symptom and clearance to return to work.
Item No.: 11
Site: Medical-Late Reporting
Violation: On the cruise from 6 April to 16 April, a food handler stated AGE symptom onset was at 1130 on 31 March and reported to medical at 1525 31 March. the crewmember ate in the crew mess but did not work at this time. The crewmember received disciplinary action.
Recommendation: When food employees meet the case definition for AGE, ensure the following actions are taken: (1) isolate in cabin or designated restricted area until symptom-free for a minimum of 48 hours; (2) follow-up with and receive approval by designated medical personnel before returning crew to work; (3) document date and time of last symptom and clearance to return to work. When nonfood employees meet the case definition for AGE, ensure the following actions are taken: (1) isolate in cabin or designated restricted area until symptom-free for a minimum of 24 hours; (2) follow-up with and receive approval by designated medical personnel before returning crew to work; (3) document the date and time of last symptom and clearance to return to work.
Item No.: 11
Site: Medical-Late Reporting
Violation: On the cruise from 26 Mar to 6 Apr, a non food handler stated AGE symptom onset was at 2300 on 30 Mar and reported to medical at 1430 on 31 Mar. The crew member did not work at this time, but did eat in the staff mess. The crewmember received disciplinary action.
Recommendation: When food employees meet the case definition for AGE, ensure the following actions are taken: (1) isolate in cabin or designated restricted area until symptom-free for a minimum of 48 hours; (2) follow-up with and receive approval by designated medical personnel before returning crew to work; (3) document date and time of last symptom and clearance to return to work. When nonfood employees meet the case definition for AGE, ensure the following actions are taken: (1) isolate in cabin or designated restricted area until symptom-free for a minimum of 24 hours; (2) follow-up with and receive approval by designated medical personnel before returning crew to work; (3) document the date and time of last symptom and clearance to return to work.
Item No.: 16
Site: Galley-
Violation: Two pans of cut cabbage were on the preparation counter. The chef indicated that they were to be added to soup for lunch and they were on time control. No four-hour discard label was on the pan.
Recommendation: If time only?rather than time in conjunction with temperature?is used as the public health control for a working supply of potentially hazardous food before cooking, or for ready-to-eat potentially hazardous food that is displayed or held for service for immediate consumption, ensure the food (1) Has an initial temperature of 5°C (41°F) or less or 57°C (135°F) or greater before placement on time control. (2) Is not be placed on temperature control again. (3) Is marked or otherwise identified to indicate the time 4 hours past the point in time when the food is removed from temperature control (if the time between service set-up and closing is greater than 4 hours. and (4) Is discarded within 4 hours of placement on time control.
Item No.: 17
Site: Preparation Room-Pastry
Violation: The cooling log entry for the peanut cheesecake in the pastry walk-in refrigerator prepared on 3 May could not be located. The cooling log entries for the vanilla cheesecake and mango cheesecake in the refrigerator prepared on 30 Apr could not be located. There was an entry on 30 Apr for New York cheesecake. The chef stated that the base for both the vanilla and mango cheesecakes was the New York cheesecake and their the cooling log entry was actually for the vanilla and mango cheesecakes.
Recommendation: Ensure logs documenting cooked potentially hazardous food cooling temperatures and times from the starting points designated in 7.3.5.2.1 thru the control points at 2 and 6 hours are maintained onboard the vessel for a period of 30 days form the date the food was placed in the cooling process. Ensure logs documenting cooling of potentially hazardous foods prepared from ingredients at ambient temperatures, with the start time to the time when 5°C (41 °F) is reached are also maintained for a period of 30 days, beginning with the day of preparation.
Item No.: 20
Site: Preparation Room-
Violation: The edges of the dough sheeter belt were frayed and in disrepair.
Recommendation: Food contact equipment must be maintained in good repair and proper adjustment: (1) Equipment must be maintained in a state of repair and condition that meets the materials, design, construction, and operating specifications of these guidelines.
Item No.: 20
Site: Buffet-Beverage Stations
Violation: Each of the two water/ice dispenser units had two slotted fasteners in the food splash zone above the water dispensers. The fasteners were corroded.
Recommendation: Ensure multiuse food-contact surfaces are: (1) Smooth; (2) Free of breaks, open seams greater than 0.8 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices; (4) Finished to have smooth welds and joints; and (5) Accessible for cleaning and inspection by one of the following methods without being disassembled, by disassembling without the use of tools, or by easy disassembling with the use of handheld tools commonly available to maintenance and cleaning personnel. Use only low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones. Prohibit the use of exposed slotted screws, Phillips head screws, or pop rivets in these areas.
Item No.: 20
Site: Galley-
Violation: The plastic container with the raw fish had a large difficult to clean crack.
Recommendation: Materials used in the construction of multiuse utensils and food contact surfaces of equipment must be: (1) durable, corrosion resistant, and nonabsorbent; (2) sufficient in weight and thickness to withstand repeated warewashing; (3) finished to have a smooth, easily cleanable surface; and (4) resistant to pitting, chipping, crazing, scratching, scoring, distortion and decomposition. Ensure multiuse food-contact surfaces are: (1) Smooth; (2) Free of breaks, open seams greater than 0.8 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices; (4) Finished to have smooth welds and joints; and (5) Accessible for cleaning and inspection by one of the following methods without being disassembled, by disassembling without the use of tools, or by easy disassembling with the use of handheld tools commonly available to maintenance and cleaning personnel. Use only low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones. Prohibit the use of exposed slotted screws, Phillips head screws, or pop rivets in these areas.
Item No.: 20
Site: Buffet-Staff Beverage Station
Violation: The ice/water dispenser had three slotted fasteners in the food splash zone above the water dispensers.
Recommendation: Ensure multiuse food-contact surfaces are: (1) Smooth; (2) Free of breaks, open seams greater than 0.8 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices; (4) Finished to have smooth welds and joints; and (5) Accessible for cleaning and inspection by one of the following methods without being disassembled, by disassembling without the use of tools, or by easy disassembling with the use of handheld tools commonly available to maintenance and cleaning personnel. Use only low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones. Prohibit the use of exposed slotted screws, Phillips head screws, or pop rivets in these areas.
Item No.: 21
Site: Buffet-Garden Cafe
Violation: On the back, worker side of the beverage station, loose and pealing sealant was found around the bottom of the counter mounted siding door frame. In addition, an excess of sealant was used to fill a hole on the bottom right corner of the frame.
Recommendation: Ensure nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material.
Item No.: 21
Site: Galley-Bistro Soda Cabinet
Violation: The handle on the left door was missing and the remaining metal was rough and sharp.
Recommendation: Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance. Ensure nonfood contact equipment is maintained in good repair and proper adjustment including: (1) Equipment maintained in a state of repair and condition that meets the materials, design, construction, and operation specifications of these guidelines; (2) Equipment components such as doors, seals, hinges, fasteners, and kick plates are kept intact, tight, and adjusted in accordance with manufacturer's specifications.
Item No.: 22
Site: Galley-Potwash
Violation: The potwash machine had been out of order since 10 March 2015. Documentation was provided indicated that parts had been ordered.
Recommendation: Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
Item No.: 22
Site: Galley-Dishwash Area
Violation: A foil lid from a yogurt cup and part of a sugar packet were in the final sanitizing rinse compartment in the in use flight-type conveyor dishwasher machine.
Recommendation: Ensure warewashing machines, drainboards, and the compartments of sinks, basins, or other receptacles used for washing and rinsing equipment, utensils, or raw foods, or laundering wiping cloths are cleaned: (1) before use; (2) throughout the day at a frequency necessary to prevent recontamination of equipment and utensils and to ensure that the equipment performs its intended function; (3) at least every 24 hours (if used).
Item No.: 26
Site: Preparation Room-
Violation: Two trays of bread dough had remnants of a yellow brown sticker on the corner.
Recommendation: Ensure food only contacts surfaces of equipment and utensils that are cleaned and sanitized. Ensure materials used in the construction of multiuse utensils and food-contact surfaces of equipment do not allow the migration of deleterious substances or impart colors, odors, or tastes to food and are safe under normal use conditions. Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 26
Site: Buffet-Starboard Beverage Stations
Violation: The ice chute on the ice/water dispenser was soiled with a dried brown residue.
Recommendation: Ensure food only contacts surfaces of equipment and utensils that are cleaned and sanitized. Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 26
Site: Preparation Room-
Violation: The felt for the baguette molder was soiled with dried dough residue.
Recommendation: Ensure materials used to make single-service and single-use articles do not allow the migration of deleterious substances and are safe. Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 26
Site: Preparation Room-
Violation: Two trays of uncooked rolls in the bakery walk-in refrigerator had remnants of a round yellow sticker.
Recommendation: Ensure materials used in the construction of multiuse utensils and food-contact surfaces of equipment do not allow the migration of deleterious substances or impart colors, odors, or tastes to food and are safe under normal use conditions. Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 27
Site: Galley-La Cucina Show Galley
Violation: The backs of two upright wine refrigerators were dusty.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 28
Site: Buffet-Great Outdoors
Violation: A crewmember was observed carrying a stack of clean plates for the buffet with the plates leaning against his upper body and contacting his jacket. In addition the top plate was not covered or inverted.
Recommendation: Store clean equipment and utensils in a self-draining position that allows air drying, and covered or inverted. Reassemble equipment so food-contact surfaces are not contaminated.
Item No.: 29
Site: Galley-Bistro Dishwash Area
Violation: The water in the handwashing sink was measured at 134°F. The area was not in operation during the inspection.
Recommendation: Ensure handwashing sinks are equipped to provide water at a temperature of at least 38°C (100°F) through a mixing valve or combination faucet. For handwash sinks with electronic sensors, and other types of handwash sinks where the user cannot make temperature adjustments, ensure the temperature provided to the user after the mixing valve does not exceed 49°C (120°F).
Item No.: 29
Site: Buffet-Garden Cafe Omelet Station 6
Violation: Plates were found on the handwashing station and a small piece of bacon was noted in the sink.
Recommendation: Ensure handwashing facilities are used for no other purpose and are accessible at all times.
Item No.: 29
Site: Galley-Dishwash Area
Violation: The temperature on the two right faucets on the three faucet sink measured 78°F. The area was in use at the time of inspection.
Recommendation: Ensure handwashing sinks are equipped to provide water at a temperature of at least 38°C (100°F) through a mixing valve or combination faucet. For handwash sinks with electronic sensors, and other types of handwash sinks where the user cannot make temperature adjustments, ensure the temperature provided to the user after the mixing valve does not exceed 49°C (120°F).
Item No.: 33
Site: Preparation Room-
Violation: Two deck tiles to the left of the soup kettle were cracked. When the inspector stepped on one of the tiles water seeped out from below.
Recommendation: Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary. Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
Item No.: 33
Site: Galley-Hot Galley
Violation: The deck grout was recessed and missing.
Recommendation: Ensure bulkheads and deckheads have smooth, hard finishes and light colored surfaces. Exception: bars may have decorative surfaces provided that they are easily cleanable.
Item No.: 35
Site: Buffet-Great Outdoors
Violation: Water was pooled in the back right corner behind the rotisserie oven. This was corrected.
Recommendation: Ensure black and gray water is discharged to the vessel's wastewater disposal system and does not pool on the deck.
Item No.: 35
Site: Preparation Room-
Violation: Water was pooled on the deck in front of the handwashing station by the entrance.
Recommendation: Ensure black and gray water is discharged to the vessel's wastewater disposal system and does not pool on the deck.
Item No.: 36
Site: Buffet-Garden Cafe Omelet Station 6
Violation: The lighting at the cooking area was less than 220 lux. The lighting at the handwashing station next to the omelet station was less than 220 lux. The bulb for the handwashing station was replaced and the level measured above 220 lux.
Recommendation: Ensure the light intensity is at least 220 lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment, and utensil storage, pantries, toilet rooms, and consumer self-service areas.
Item No.: 38
Site: Galley-Room Service
Violation: One upright freezers had been out of order since 17 Jan 2015. The other freezer has not worked since Mar 2015.
Recommendation: Ensure only articles necessary for the food service operation are stored in food preparation, food storage, and warewashing areas.