Item No.:
08
|
Site:
Potable Water-Bunkering Test
|
Violation:
The crew member's multiple manual bunkering tests were more than 1ppm difference when compared to multiple inspector tests. It was determined the crew member was using a photometer tablet reagent from a manufacturer that was different than the photometer.
|
Recommendation:
Ensure test kits are accurate to within 0.2 mg/L (ppm) for halogen and have a testing range of free residual halogen normally maintained in the potable water system. Ensure test kits for pH are accurate to within 0.2.
|
|
Item No.:
08
|
Site:
Potable Water-Engine Room
|
Violation:
Multiple potable water lines throughout the engine room were not properly striped as potable water. Additionally, the distillate and permeate water lines were not striped blue/gray/blue.
|
Recommendation:
Stripe or paint potable water lines either in accordance with ISO 14726 (blue/green/blue) or blue only. Stripe or paint distillate and permeate lines directed to the potable water system in accordance with ISO 14726 (blue/gray/blue). Ensure no other lines have the above color designations. Stripe or paint these lines at 5 meters (15 feet) intervals and on each side of partitions, decks, and bulkheads, except where decor would be marred by such markings, including potable water supply lines in technical lockers. Do not stripe or paint potable water lines after reduced pressure assemblies as potable water. Identify all refrigerant brine lines and nonpotable chilled water lines in all food areas, such as on ice machines, ice cream machines, etc., with either ISO 14726 (blue/white/blue) or by another uniquely identifiable method to prevent cross-connections.
|
|
Item No.:
08
|
Site:
Potable Water-Bunkering Records
|
Violation:
Bunkering records for 6 January 2023 did not include a bunkering pretest. For the same record, bunkering began at 1510, however, at least 2ppm free chlorine was not reached until 1600. The ship was taking manual tests every hour in lieu of a continuous chart recorder.
|
Recommendation:
Conduct a free halogen residual and pH test on the shore-side water supply before starting the potable water bunkering process to establish the correct halogen dosage. Record the results of the pretest and ensure they are available for review during inspections. Adjust the free halogen residual level to at least 2.0 MG/L (ppm) and the pH not to exceed 7.8 within 30 minutes of the start of the bunkering and production processes.
|
|
Item No.:
08
|
Site:
Potable Water-Bunkering Records
|
Violation:
Bunkering records for 9 January 2023 did not include a bunkering pretest. For the same record, more than one hour elapsed between hourly tests, 1028 - 1145. The ship was taking manual tests every hour in lieu of a continuous chart recorder.
|
Recommendation:
Conduct a free halogen residual and pH test on the shore-side water supply before starting the potable water bunkering process to establish the correct halogen dosage. Record the results of the pretest and ensure they are available for review during inspections. After the free residual halogen level of at least 2.0 mg/L (ppm) and pH level not exceeding 7.8 have been reached, monitor the free residual halogen and pH at least hourly during the bunkering of potable water.
|
|
Item No.:
08
|
Site:
Potable Water-Testable Backflow Devices
|
Violation:
There were no records to indicate the testable backflow prevention devices were tested after they were installed in the shipyard (approximately October 2022). Ship personnel stated the yard did conduct the tests in the yard however they did not have the records to document. The ship presented a backflow test kit but stated they have yet to conduct any testing.
|
Recommendation:
Inspect and test backflow prevention devices requiring testing (e.g., reduced pressure backflow prevention devices and pressure vacuum breakers) with a test kit after installation and at least annually. Maintain test results showing the pressure differences on both sides of the valves.
|
|
Item No.:
08
|
Site:
Potable Water-Cross-Connection Control Log
|
Violation:
The cross-connection log did not include all the installed testable and non-testable backflow devices. The log also incorrectly identified several types of devices installed. Additionally, the log for the testable devices did not include the plumbing system component that was being protected.
|
Recommendation:
Ensure the cross-connection control program includes at a minimum: a complete listing of cross-connections and the backflow prevention method or device for each, so there is a match to the plumbing system component and location. Include air gaps on the listing. Ensure a schedule for inspection frequency is set. Maintain a log documenting the inspection and maintenance in written or electronic form, and ensure it is available for review during inspections.
|
|
Item No.:
08
|
Site:
Potable Water-Tank Maintenance
|
Violation:
The free halogen test result was not documented after the tanks were disinfected prior to ship delivery from the yard in October 2022.
|
Recommendation:
Ensure the empty tank cleaning and disinfection procedure is only used for routine cleaning and disinfection It is not approved for known or suspected contaminated tanks. Ensure the following steps are followed: 1) Remove (strip) all water from the tank; 2) Clean all tank surfaces, including filling lines, with an appropriate detergent; 3) Rinse all surfaces of the tank thoroughly with potable water; 4) Remove (strip) the rinse water from the tank; 5) Wet all surfaces of the tank with at least a 200-mg/L (ppm) solution of chlorine (this can be done using new, clean mops, rollers, sprayers, etc.). Ensure the tank surfaces remain wet with the chlorine solution for at least 2 hours. Check, monitor, and document the disinfection concentration and contact time; 6) Refill the tank and verify the free residual halogen is less than or equal to 5.0 mg/L (ppm) before placing the tank back into service. Document the free residual halogen level.
|
|
Item No.:
09
|
Site:
Recreational Water Facilities-Deck 5 - Deep Pool
|
Violation:
This recreational water facility had jets to create a swim current for users. This design classifies the pool as an activity pool that requires a 2-5ppm free residual halogen. The ship was treating the pool as a regular pool and maintaining halogenation at only 1-5ppm. Records showed chlorine residual values were less than 2ppm consistently since the delivery of the ship in approximately October 2022.
|
Recommendation:
Maintain a free residual halogen in recirculated RWFs in the following ranges: (4) interactive RWFs (activity pools), between 2.0 and 5.0 mg/L (ppm).
|
|
Item No.:
10
|
Site:
Recreational Water Facilities-Deck 5 - Deep Pool
|
Violation:
The turnover rate for the deep pool was calculated at 4 hours for a regular pool rather than 2 hours for an activity pool (>24 inches). Staff stated they could achieve the 2-hour turnover rate by adjusting the pumps and replacing the sand filter with cartridge filtration.
|
Recommendation:
For RWFs with skim gutters, ensure that the fill level of the RWF is to the level of the skim gutters. Design recirculation systems and equipment, including chemical control equipment, UV disinfection systems, filter, and pumps to maintain adequate water chemistry control while operating at the following minimum turnover rates:(8) interactive RWF or activity pool greater than 610 millimeters (24 inches) deep: 2 hours.
|
|
Item No.:
10
|
Site:
Recreational Water Facilities-Deck 5 - Deep Pool
|
Violation:
The shepherd's hook pole was not long enough to reach the center of the deepest portion of the pool and at least 2 feet from the closest edge.
|
Recommendation:
Provide a rescue or shepherd?s hook and an approved flotation device at a prominent location (visible from the full perimeter of the pool) at each RWF that has a depth of 1 meter (3 feet) or greater. Mount these devices in a manner that allows for easy access during an emergency. Ensure the pole of the rescue or shepherd?s hook is long enough to reach the center of the deepest portion of the pool from the side plus 2 feet. Ensure it is a light, strong, nontelescoping material with rounded, nonsharp ends. Ensure the approved flotation device includes an attached rope that is at least 2/3 of the maximum pool width. Ensure the rescue or shepherd?s hook is long enough to touch the bottom center of the deepest portion of the RWF plus 2 feet (0.6 meters) as measured from the closest edge without an obstruction. This edge can only be used for measurement if someone could freely walk down both sides without an obstruction such as a waterfall, fountain, statue, etc. For a rectangular pool, ensure the shorter distance is measured from the long side of the rectangle as long as there are no obstructions. Measure the 2 feet (0.6 meters) distance from where the shepherd?s hook crosses the fill line of the RWF.
|
|
Item No.:
20
|
Site:
Buffet-Employee Dining Room
|
Violation:
Slotted fasteners were around the dispensing nozzles of the ice machine and the juice machine.
|
Recommendation:
Ensure multiuse food-contact surfaces use only low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones. Prohibit the use of exposed slotted screws, Phillips head screws, or pop rivets in these areas.
|
|
Item No.:
22
|
Site:
Bar-Marina Terrace Bar
|
Violation:
The undercounter glasswash machine was out of service since October 2022. Employees stated the machine was to be replaced the day of the inspection.
|
Recommendation:
Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
|
|
Item No.:
23
|
Site:
Galley-Deck 4 - Evrima Room
|
Violation:
During multiple cycles, the potwash machine's wash temperature measured 140-143°F at the utensil surface and 145°F in the wash tank, as measured by both the inspector's and crew member's thermometers. The wash gauge read 139-143°F. At the end of the inspection, the team returned to the potwash machine where the wash temperature measured 165°F by both the inspector and crew member. The final sanitizing rinse temperature measured correctly during all cycles.
|
Recommendation:
Ensure the temperature of the wash solution in spray type warewashers that use hot water to sanitize is not less than: (1) 74°C (165°F) for a stationary-rack, single-temperature machine; (2) 66°C (150°F) for a stationary-rack, dual-temperature machine; (3) 71°C (160°F) for a single-tank, conveyor, dual-temperature machine; (4) 66°C (150°F) for a multi-tank, conveyor, multi-temperature machine.
|
|
Item No.:
24
|
Site:
Galley-Deck 4 - Evrima Room - Coffee Station
|
Violation:
The container of sanitizing solution measured less than 50 ppm chlorine.
|
Recommendation:
Ensure sanitizing solutions are used with the following concentrations: (1) A chlorine solution with a concentration between 50 mg/L (ppm) and 200 mg/L (ppm).
|
|
Item No.:
26
|
Site:
Pantry-Living Room Bar - Ice/water dispenser
|
Violation:
Black residue was on the water dispensing line and to the left and right of the ice cuber.
|
Recommendation:
Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
|
|
Item No.:
28
|
Site:
Galley-Pool House
|
Violation:
Previously cleaned and sanitized silverware were stored upright and uncovered in the clean storage.
|
Recommendation:
Store clean equipment and utensils in a self-draining position that allows air drying, and covered or inverted.
|
|
Item No.:
28
|
Site:
Preparation Room-
|
Violation:
A cooler used to transport bottled beverages was wet inside and stored with the lid closed after it was cleaned and sanitized.
|
Recommendation:
After cleaning and sanitizing, ensure equipment and utensils are air dried or adequately drained before contact with food.
|
|
Item No.:
36
|
Site:
Galley-Deck 4 - Evrima Room - Pastry
|
Violation:
The light intensity measured less than 110 lux to the left of oven #1.
|
Recommendation:
Ensure the light intensity is at least 110 lux (10 foot candles) at a distance of 75 centimeters (30 inches) above the deck when in use, in walk-in refrigerator units and dry storage areas, and in other areas and rooms during periods of cleaning. Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
|
|
Item No.:
38
|
Site:
Other-Deck 3 - Trolley Wash
|
Violation:
A wet mop head was stored on the deck. This was corrected by staff.
|
Recommendation:
After use, ensure mops are placed in a position that allows them to air-dry without soiling walls, equipment, or supplies.
|
|
Item No.:
39
|
Site:
Buffet-Employee Dining Room
|
Violation:
One live fly was near the soiled dish drop-off. The area was in operation during the inspection.
|
Recommendation:
Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
|
|
Item No.:
44
|
Site:
Potable Water-Bunkering Test
|
Violation:
A crew member was using a photometer tablet reagent from a manufacturer that was different than the photometer. The crew member's test result was much lower than repeated tests by both inspector's tests.
|
Recommendation:
Ensure the supervisor or person in charge of potable water operations on the vessel demonstrates to VSP?during inspections and on request-knowledge of potable water operations, is able to demonstrate this knowledge by compliance with Section 5 of the VSP 2018 Operations Manual or by responding correctly to the inspector?s questions as they relate to the specific operation, and properly trains employees to comply with Section 5 of the VSP 2018 Operations Manual as it relates to their assigned duties.
|
|