|
|
|
Item No.:
06
|
|
Site:
Potable Water-
|
|
Violation:
The distribution charts were not consistently changed on a daily basis. The charts ran for two days on 06/30-07/01/2006, 07/02-07/03/2006, 09/01-09/02/2006, 09/29-09/30/2006.
|
|
Recommendation:
Ensure that halogen analyzer-chart recorder charts are changed, initialed, and dated daily and contain notations of any unusual water events in the potable water system.
|
|
|
Item No.:
06
|
|
Site:
Potable Water-
|
|
Violation:
During July 2006 there were a few distribution system halogen analyzer charts where the calibration check was not recorded.
|
|
Recommendation:
Ensure that the calibration check is recorded daily. This should be done even when an adjustment is not made.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-
|
|
Violation:
A review of the production log noted numerous instances where the time of the free chlorine residual test was not recorded. The only indication of the time was that the test occurred during a 4-hour shift. Given this log it was possible to exceed the 4-hour limit between tests. This was noted during the last inspection.
There were some blank cells in the log where the free chlorine residual should have been recorded. Per the engineer production had stopped. There was no indication in the logs of the start and stop times for production of water for the potable water system.
|
|
Recommendation:
Ensure that free residual halogen monitoring is performed at least hourly during the bunkering of potable water and performed at least once every 4 hours during the onboard production of potable water. Ensure that accurate records of this monitoring are maintained aboard for 12 months and are available to the VSP for review during inspections. Ensure that the time that the tests are conducted are recorded in the log. Additionally, record the start and stop times for production so that blank cells become self-explanatory.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-
|
|
Violation:
The potable water lines in the garbage room were not painted or striped blue.
|
|
Recommendation:
Ensure that potable water piping and fittings are painted or stripped auxiliary blue, or in accordance with ISO 14726, at 5 m (15 feet) intervals on each side of partitions, decks, and bulkheads in all spaces, except where the decor would be marred by such markings.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-
|
|
Violation:
There was a short listing of devices at the back of the comprehensive cross-connection control program that had the heading of various. This listing included the devices used but not the cross-connection or location of these devices and cross-connections.
|
|
Recommendation:
The vessel shall provide a comprehensive cross- connection control program that provides safe connections to the potable water system through air gaps or appropriate backflow devices at the following locations, if present:
(1) Potable water supply lines to swimming pools, whirlpool spas, hot tubs, bathtubs, showers, and similar facilities; (2) Photographic laboratory developing machines and utility sinks; (3) Beauty and barber shop spray-rinse hoses; (4) Potable water faucets where hoses are connected or can be connected by threaded or quick-connect outlets such as those serving tanks containing chlorine and other chemicals, and deck taps; (5) Garbage grinders and pulpers; (6) Mechanical warewashing machines; (7) Hospital and laundry equipment; (8) Air conditioning expansion tanks; (9) Boiler feed water tanks; (10) Fire systems; (11) Toilets; (12) Potable water, bilge, and sanitary pumps that require priming; (13) Freshwater or saltwater ballast systems; (14) Bilge or other waste water locations; (15) International shore connection; and (16) Any other connection between potable and non-potable water systems. Ensure that the cross-connection control program includes at minimum: a complete listing of cross-connections and the backflow prevention method/device for each, so that there is a match to the plumbing system component and location, and an inspection frequency. Ensure that air-gaps are included in the listing.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-
|
|
Violation:
The potable water hoses were not clearly labeled "potable water only" at the connection ends. Some of the wording was faded and at least one hose was labeled "fresh water".
|
|
Recommendation:
Ensure that potable water hoses are labeled for use with the words "potable water only" in letters at least 13mm (0.5 inch) at each connecting end.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-
|
|
Violation:
The reduced pressure backflow protection devices in the deck 8 forward whirlpool pump room and the deck 8 main pool pump room were leaking.
The middle test results were missing from the records of the reduced pressure backflow protection device testing.
|
|
Recommendation:
Ensure that all three test results are recorded for each device per written company policy. Ensure that backflow preventers are maintained in good repair. Ensure that backflow prevention devices are periodically inspected and any failed units are replaced.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Aft Pool
|
|
Violation:
There were no depth markers at this pool.
|
|
Recommendation:
Ensure that the depth of each pool is prominently displayed so that it can be seen from the deck and in the pool. Ensure that depth markers are labeled in feet or meters, or both. Additionally, ensure that depth markers are installed for every 1 m (3 feet) in change of depth.
|
|
|
Item No.:
10
|
|
Site:
DO NOT USE (whirlpool/spa)-Aft Whirlpool
|
|
Violation:
The standard precautions and risks sign did not warn immunocompromised individuals.
|
|
Recommendation:
Ensure that the standard precautions and risks sign warns immunocompromised individuals.
|
|
|
Item No.:
10
|
|
Site:
DO NOT USE (whirlpool/spa)-
|
|
Violation:
There was a missing suction drain cover and a cracked suction drain cover in the crew whirlpool. These were anti-entrapment drain covers.
The drain cover in the children's pool was not stamped to indicate that it was anti-entrapment. There was no documentation for this drain cover.
|
|
Recommendation:
Ensure that anti-entrapment drain covers or other drains that prevent entrapment hazards as specified in U.S. Consumer Product Safety Publication 363-009801 (dual drains/channel drains) are provided on swimming pools and whirlpool spas. Ensure that drain covers have either the plumbing/engineering approving organization stamp and flow rate affixed to the cover, or that a letter is maintained aboard the vessel certifying that the cover meets the safety requirements outlined in AMSE/ANSI A112.19.8M or an equivalent standard. Replace damaged or missing suction drain covers.
|
|
|
Item No.:
10
|
|
Site:
DO NOT USE (whirlpool/spa)-
|
|
Violation:
A fastener was missing on the anti-entrapment drain cover in the starboard aft whirlpool.
One suction drain cover was missing at the port whirlpool and one was missing at the starboard main whirlpool. Two suction drain covers were missing at the deck 10 whirlpool. The missing drain covers were suction fitting anti-entrapment drain covers.
|
|
Recommendation:
Replace the missing fastener. Ensure that anti-entrapment drain covers or other drains that prevent entrapment hazards as specified in U.S. Consumer Product Safety Publication 363-009801 (dual drains/channel drains) are provided on swimming pools and whirlpool spas. Ensure that drain covers have either the plumbing/engineering approving organization stamp and flow rate affixed to the cover, or that a letter is maintained aboard the vessel certifying that the cover meets the safety requirements outlined in AMSE/ANSI A112.19.8M or an equivalent standard.
|
|
|
Item No.:
10
|
|
Site:
DO NOT USE (whirlpool/spa)-Backwashing
|
|
Violation:
The backwashing was conducted automatically. There was no indication that backwashing ended when the water was clear.
|
|
Recommendation:
Ensure that granular filters are backwashed at least daily. Repeat backwashing, if necessary, until the water viewed through the sight glass or discharge point is clean flowing.
|
|
|
Item No.:
10
|
|
Site:
DO NOT USE (whirlpool/spa)-Whirlpool Halogen Records
|
|
Violation:
A review of the whirlpool logs noted the chlorine residual was 10 ppm during shock treatment and bromine levels of less than 10 ppm during the same time. Per the housekeeping staff, the whirlpools were closed during shock halogenation but the logs did not indicate that.
The logs also noted the same start time and stop time during shock chlorination for numerous days which meant that the shock halogenation was conducted for less than 1 hour.
|
|
Recommendation:
Ensure that a free residual halogen level is maintained in the whirlpool spa [between 3.0 mg/l (ppm) and 10 mg/L (ppm) for chlorine or between 4.0 mg/L (ppm) and 10 mg/L (ppm)]. Ensure that the free residual halogen is increased to at least 10.0 mg/L (ppm) in whirlpool spas and circulated for at least 1 hour at the end of each day. It is not advisable to keep the whirlpools open during shock halogenation.
|
|
|
Item No.:
13
|
|
Site:
Other-Hamburger Grill
|
|
Violation:
When questioned the employee cooking hamburgers and chicken indicated that they were to be cooked to 120F. All of the other staff in the area were aware of the proper cooking temperatures for these food items.
|
|
Recommendation:
Person in charge: Ensure that employees are properly trained in food safety as it relates to their assigned duties.
|
|
|
Item No.:
19
|
|
Site:
Galley-
|
|
Violation:
Small round openings were noted between the technical compartment and the ice bin of the crushed ice machine in the center galley. A small amount of water was noted in the technical compartment. This unit was out of service at the time of the inspection.
|
|
Recommendation:
Provide appropriate plugs for the openings to prevent contamination from going to the ice bin.
|
|
|
Item No.:
20
|
|
Site:
Galley-
|
|
Violation:
There were a few chipped plates noted throughout the galley.
|
|
Recommendation:
Ensure that materials used in the construction of multiuse utensils and food-contact surfaces of equipment are: (1) Durable, corrosion-resistant, and nonabsorbent; (2) Sufficient in weight and thickness to withstand repeated warewashing; (3) Finished to have a smooth, easily cleanable surface; and (4) Resistant to pitting, chipping, crazing, scratching, scoring, distortion, and decomposition.
|
|
|
Item No.:
21
|
|
Site:
Galley-
|
|
Violation:
There were gaps, seams, and rough edges along the edges of equipment and the bulkhead, making cleaning difficult.
|
|
Recommendation:
Ensure that nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material. Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
21
|
|
Site:
Galley-
|
|
Violation:
The side panel of the combination oven was loose, making cleaning difficult.
|
|
Recommendation:
Re-attach the side panel.
|
|
|
Item No.:
21
|
|
Site:
Preparation Room-
|
|
Violation:
The handle of the cabinet door was loose.
|
|
Recommendation:
Tighten the door handle.
|
|
|
Item No.:
22
|
|
Site:
Galley-Forward Dishwash
|
|
Violation:
The 2nd to left final rinse spray nozzle was clogged.
|
|
Recommendation:
Ensure that all spray nozzles are spraying when the unit is in active use.
|
|
|
Item No.:
24
|
|
Site:
Buffet-Coffee Bar
|
|
Violation:
The solution in the sanitize bucket was tested at less than 50 ppm. This was corrected.
|
|
Recommendation:
Ensure that a chlorine solution used as a sanitizing solution has a concentration between 50 mg/L (ppm) and 200 mg/L (ppm).
|
|
|
Item No.:
26
|
|
Site:
Bar-Lobby Bar
|
|
Violation:
A few of the glasses were soiled/cloudy.
|
|
Recommendation:
Ensure that food-contact surfaces of equipment and utensils are clean to sight and touch.
|
|
|
Item No.:
26
|
|
Site:
Galley-
|
|
Violation:
There was mold noted on the ice chute inside the ice machine located near the chef's office.
|
|
Recommendation:
Ensure that food only contacts surfaces of equipment and utensils that are cleaned and sanitized.
|
|
|
Item No.:
26
|
|
Site:
Buffet-Mess Rooms
|
|
Violation:
The water nozzles located in the juice machines were soiled.
|
|
Recommendation:
Ensure that food only contacts surfaces of equipment and utensils that are cleaned and sanitized.
|
|
|
Item No.:
28
|
|
Site:
Galley-Clean Plate Storage
|
|
Violation:
There were numerous small plates and a few large plates that were wet stacked, impeding air drying.
|
|
Recommendation:
Ensure that clean equipment and utensils are stored: (1) In a self-draining position that allows air drying; and (2) Covered or inverted.
|
|
|
Item No.:
28
|
|
Site:
Buffet-Grand Buffet Starboard Beverage Station
|
|
Violation:
Numerous wet cups were stacked and placed out for service.
|
|
Recommendation:
After cleaning and sanitizing, ensure that equipment and utensils are air-dried or adequately drained before contact with food.
|
|
|
Item No.:
28
|
|
Site:
Buffet-Coffee Bar
|
|
Violation:
Numerous wet glasses were stacked and placed out for service at the adjacent juice station.
|
|
Recommendation:
After cleaning and sanitizing, ensure that equipment and utensils are air-dried or adequately drained before contact with food.
|
|
|
Item No.:
28
|
|
Site:
Buffet-Coffee Bar
|
|
Violation:
Only one blender pitcher was provided at this bar. Per the staff the pitcher was washed every 4 hours. There was no possibility for this piece of equipment to air dry between washing and the next use. This bar was said to be open for approximately 12 hours each day. This was noted during the last inspection but at that time the vessel was only washing the pitcher once per day at the closing time of the bar.
|
|
Recommendation:
Provide a minimum of two blender pitchers at this location.
|
|
|
Item No.:
33
|
|
Site:
Galley-
|
|
Violation:
The deck grouting throughout the lido center galley and buffet pantry was worn making cleaning difficult.
|
|
Recommendation:
Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
|
|
|
Item No.:
33
|
|
Site:
Buffet-Grand Buffet Starboard Beverage Station
|
|
Violation:
The finish near the deck was peeling, making cleaning difficult. Mold was noted in this area.
|
|
Recommendation:
Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning. Ensure that decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, are cleaned as often as necessary.
|
|
|
Item No.:
33
|
|
Site:
Buffet-Grand Buffet Starboard
|
|
Violation:
The area of the deck near the bulkhead juncture was soiled/stained.
|
|
Recommendation:
Ensure that decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, are cleaned as often as necessary.
|
|
|
Item No.:
33
|
|
Site:
Galley-
|
|
Violation:
There were a few screws missing in the deckhead above the soup kettles, making cleaning difficult.
|
|
Recommendation:
Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
|
|
|
Item No.:
33
|
|
Site:
Other-Pizzeria
|
|
Violation:
A gap was noted between the metal strip and the bulkhead at the starboard section under the back counter mounted pizza oven on the right side. This metal strip was along the cove base.
|
|
Recommendation:
Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
|
|
|
Item No.:
33
|
|
Site:
Galley-Center Galley
|
|
Violation:
There were missing screws in the deckheads above the fryers, making cleaning difficult.
|
|
Recommendation:
Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
|
|
|
Item No.:
33
|
|
Site:
Galley-Garde Manger
|
|
Violation:
The metal column was damaged near the walk-in refrigerator, making cleaning difficult.
|
|
Recommendation:
Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
|
|
|
Item No.:
33
|
|
Site:
Buffet-Coffee Bar
|
|
Violation:
Dust was noted on the deck under the counters.
|
|
Recommendation:
Ensure that decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, are cleaned as often as necessary.
|
|
|
Item No.:
33
|
|
Site:
Buffet-Ice Cream Stations
|
|
Violation:
The deck-bulkhead juncture was not coved, making cleaning difficult.
|
|
Recommendation:
Ensure that bulkhead and deck junctures are coved (including galleys, pantries, deck/counter junctures at buffets, bars, waiter stations, and dining room work counters).
|
|
|
Item No.:
33
|
|
Site:
Bar-Pool Bar
|
|
Violation:
The cove area under the counters was soiled.
|
|
Recommendation:
Ensure that decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, are cleaned as often as necessary.
|
|
|
Item No.:
34
|
|
Site:
Buffet-Grand Buffet Starboard Beverage Station
|
|
Violation:
A leak was noted under the station near the ice unit.
|
|
Recommendation:
Ensure that a plumbing system in a food area is maintained in good repair.
|
|
|
Item No.:
36
|
|
Site:
Buffet-Coffee Bar
|
|
Violation:
The decorative light cover behind the coffee machine was cracked. This cover was flat and parallel to the bulkhead and did not enclose the bulb
|
|
Recommendation:
Replace the light cover. Ensure that the bulbs are shatter-resistant.
|
|
|
Item No.:
37
|
|
Site:
Galley-Center Galley
|
|
Violation:
There was condensate dripping from the deckhead and bulkhead above the kettles in the starboard side soup area.
|
|
Recommendation:
Ensure that ventilation hood systems and devices are sufficient in number and capacity to prevent grease or condensation from collecting on bulkheads and deckheads.
|
|
|
Item No.:
37
|
|
Site:
Galley-Forward Dishwash
|
|
Violation:
There was condensate dripping from the deckhead on to the front end of the dishwash machine.
|
|
Recommendation:
Ensure that ventilation hood systems and devices are sufficient in number and capacity to prevent grease or condensation from collecting on bulkheads and deckheads.
|
|
|
Item No.:
37
|
|
Site:
Galley-Forward Line
|
|
Violation:
There was water noted dripping from the deckhead on to the deck across from the grill.
|
|
Recommendation:
Find and eliminate the source of the drip.
|
|
|
Item No.:
41
|
|
Site:
Housekeeping-Spa/GYM
|
|
Violation:
The tissue for the toilet room egress was located in the toilet room stalls. The handwash sinks were outside of the stalls except for the handicap accessible toilet stall. This required individuals to use bare hands to exit the toilet area after handwashing.
|
|
Recommendation:
Ensure that the tissue dispensers are located near the exit doors of the toilet area. The dispensers should be located so that individuals can access them after handwashing.
|
|
|
Item No.:
41
|
|
Site:
Ventilation-
|
|
Violation:
Per the refrigeration engineer the vessel did not have a plan for the cleaning of the air conditioning units. In addition, there were no records to indicate when these units were cleaned. AC 2.10 S 1 was inspected and the condensate collection area was heavily soiled. Per the engineer this area was cleaned on a monthly basis but records could not be produced to show this.
|
|
Recommendation:
Ensure that evaporative condensers are inspected at least annually and cleaned as necessary to remove scale and that sediment and cooling coils and condensate pans are cleaned as necessary to remove dirt and organic material. Ensure that vessels have a written plan to inspect, clean, and maintain the heating, ventilation, and air conditioning systems in accordance with manufactures recommendations and industry standards. Ensure that the plan is available for review during inspections.
|
|
|
Item No.:
41
|
|
Site:
Housekeeping-Outbreak Prevention and Response Plan
|
|
Violation:
The Outbreak Prevention and Response Plan did not state the disinfection frequency of all public areas. The staff stated the frequency was on a continuous basis. However, they were not able to locate that information in the plan.
|
|
Recommendation:
Ensure that the outbreak prevention and response plan notes the disinfection frequency to be used.
|
|