Skip directly to site content Skip directly to page options

Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: Seadream II Cruise Line: Sea Dream Yacht Club Inspection Date: 03/30/2008 Inspection Score: 96
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 17
Site: Galley-Main Galley - Cooling Log
Violation: There was a randomness about the recording of cooling from the initial cooking to the control points at 2 hours and 4 hours beyond. Certain staff initials showed the entire cooling period, while others only recorded the first value, when the item was placed in the blast chiller, and nothing thereafter.
Recommendation: Ensure that logs documenting cooked, potentially hazardous food cooling temperatures and times from the starting points designated in 7.3.5.2.1 thru the control points at 2 and 6 hours are maintained onboard the vessel for a period of 30 days form the date the food was placed in the cooling process. Ensure that logs documenting cooling of potentially hazardous foods prepared from ingredients at ambient temperatures, with the start time to the time when 5°C (41 °F) is reached are also maintained for a period of 30 days, beginning with the day of preparation.
Item No.: 20
Site: Galley-Main Galley - Garde Manger
Violation: There was a soft silicone sealant applied on the backplate of the counter model slicer. In examining the seal at the backplate it was clear that this was tight and did not require sealant.
Recommendation: Remove the soft sealant from the joint at the slicer backplate at the blade area.
Item No.: 22
Site: Galley-Main Galley - Dishwash
Violation: The in-use conveyor dishwasher had all 5 of the lower final rinse spray arm nozzles clogged during the final rinse cycle. There were two of these nozzles clogged in the previous VSP inspection on 14 November 2007. Staff immediately repaired the machine.
Recommendation: Ensure that warewashing equipment is maintained in good repair and proper adjustment including: (1) Being maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; and (2) Maintaining water pressure, and water temperature measuring devices in good repair and ensuring their accuracy within the intended range of use.
Item No.: 18
Site: Galley-Main Galley - Walk-in Refrigerator #2
Violation: There was a covered container of shell egg whites stored on an upper shelf beside and above various covered ready-to-eat products like desserts and milk in walk-in refrigerator #2.
Recommendation: Ensure that food is protected from cross-contamination by: (1) Physically separating raw animal foods during storage, preparation, holding, and display from raw ready-to-eat food including other raw animal food such as fish for sushi or molluscan shellfish, or other raw ready-to-eat food such as vegetables, and cooked ready-to-eat food; so products do not physically touch, and so as to prevent dripping of one product into another.
Item No.: 39
Site: Galley-Main Galley - Butcher Shop
Violation: There was a live housefly on top of the floor model grinder cover in the Butcher Shop.
Recommendation: Ensure that the presence of insects, rodents, and other pests is effectively controlled to minimize their presence in the food storage, preparation, service areas, warewashing, and utensil storage areas aboard a vessel.
Item No.: 33
Site: Galley-Main Galley - Garde' Manger, Butcher Shop, and Pastry
Violation: There was surface pitting of the decks in various areas of the Garde' Manger, Butcher Shop and Pastry in the main galley. Staff stated these areas are to be repaired in the November 2008 dry dock.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
Item No.: 34
Site: Other-Outdoor Veranda - Cold Pantry
Violation: There was standing water on the deck beneath the technical compartment of the cold basin near the handwash sink. It appeared there was no deck sink installed to collect drain water from the two cold-top basins in the counter above.
Recommendation: Ensure that a plumbing system in a food area is maintained in good repair.
Item No.: 33
Site: Other-Outdoor Veranda - Cold Pantry
Violation: There was standing water on the deck beneath the technical compartment of the cold basin near the handwash sink. It appeared there was no deck sink installed to collect drain water from the two cold-top basins in the counter above.
Recommendation: Ensure that decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, are cleaned as often as necessary.
Item No.: 33
Site: Other-Outdoor Veranda - Cold Pantry
Violation: The deck sink in the technical compartment below the cold basins near the pantry door was heavily soiled with mold debris and other waste at the deck sink drain cover.
Recommendation: Ensure that decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, are cleaned as often as necessary.
Item No.: 39
Site: Other-Outdoor Veranda - Cold Pantry
Violation: One drain fly was noted flying in the pantry area during the inspection.
Recommendation: Ensure that the presence of insects, rodents, and other pests is effectively controlled to minimize their presence in the food storage, preparation, service areas, warewashing, and utensil storage areas aboard a vessel.
Item No.: 33
Site: Bar-Top of the Yacht Bar and Pantry
Violation: The deckhead construction over the bar and pantry behind was a soft sailcloth material which is not hard/durable as specified in the VSP Operations Manual 2005. This was noted in the November 07 VSP inspection.
Recommendation: Ensure that bulkheads and deckheads have smooth, hard finishes, and light colored surfaces. Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
Item No.: 28
Site: Pantry-Top of the Yacht Bar - Pantry
Violation: There were random wood and glass barriers or doors stored directly above the clean glass storage rack in the pantry, and the rack and the bin of clean items on top were not protected with a cover.
Recommendation: Provide a cover on the top of the clean glass storage rack to prevent debris falling from items stored above.
Item No.: 10
Site: Recreational Water Facilities-Pool - Drain Cover
Violation: The single drain cove on the swimming pool had an anti-entrapment design, but there was no documentation on the cover or onboar confirming that it was approved or tested and met the requirements in ASME/ANSI A112.19.8M. This was noted on the November 2007 inspection. An order form from mid-March was reviewed and staff expect the replacement delivery within 2 weeks.
Recommendation: Ensure that anti-entrapment drain covers or other drains that prevent entrapment hazards as specified in U.S. Consumer Product Safety Publication 363-009801 (dual drains/channel drains) are provided on swimming pools and whirlpool spas. Ensure that drain covers have either the plumbing/engineering approving organization stamp and flow rate affixed to the cover, or that a letter is maintained aboard the vessel certifying that the cover meets the safety requirements outlined in AMSE/ANSI A112.19.8M or an equivalent standard.
Item No.: 03
Site: Potable Water-Potable Water - Production
Violation: A review of the potable water reverse osmosis system production revealed two specific record types. One is an electronic form on a computer which represents a one per 4 hour watch reading taken from the production analyzer. The second is the analyzer reading printed out on a circular recording chart. Both the values seemed to be inaccurate regarding the halogenation values. There were no notations on the analyzer chart specifying the start and stop time of production. There were periods in both records where the halogenation was below 2 ppm. Staff stated there were manual adjustments made, but there is no notation on the charts or on the remarks column of their electronic form that this was done. As a result, it was unclear from the two records that the ship was halogenating water above 2 ppm throughout the production period.
Recommendation: Ensure that potable water is continuously halogenated to at least 2.0 mg/L (ppm) free residual halogen at the time of bunkering or production with an automatic halogenation device that is controlled by a flow meter.
Item No.: 08
Site: Potable Water-Potable Water - Production
Violation: A review of the potable water reverse osmosis system production revealed two specific record types. One is an electronic form on a computer which represents a one per 4 hour watch reading taken from the production analyzer. The second is the analyzer reading printed out on a circular recording chart. Both the values seemed to be inaccurate regarding the halogenation values. There were no notations on the analyzer chart specifying the start and stop time of production. There were periods in both records where the halogenation was below 2 ppm. Staff stated there were manual adjustments made, but there is no notation on the charts or on the remarks column of their electronic form that this was done. As a result, it was unclear from the two records that the ship was halogenating water above 2 ppm throughout the production period. These record conflicts were mostly found in the month of March, but some in February and January 2008 were also present.
Recommendation: Ensure that free residual halogen monitoring is performed at least hourly during the bunkering of potable water and performed at least once every 4 hours during the onboard production of potable water. Ensure that accurate records of this monitoring are maintained aboard for 12 months and are available to the VSP for review during inspections.
*Inspections scores of 85 or lower are NOT satisfactory