Item No.:
10
|
|
Site:
DO NOT USE (whirlpool/spa)-
|
|
Violation:
There were a few days where the shock halogenation was not recorded.
|
|
Recommendation:
Ensure that a written or electronic record of whirlpool spa filter inspection, backwashing, core sample sedimentation test, and shock halogenation (concentration and contact time) is maintained and available for review during inspections.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Main Pool
|
|
Violation:
The shepherd's hook secured with a knotted rope and was not easy to access.
|
|
Recommendation:
Ensure that an easy-access shepherd's hook and approved floatation device (with a length of line 1/2 the pool width or 16 m (50 feet)) is provided at a prominent location near each public swimming pool.
|
|
|
Item No.:
30
|
|
Site:
Buffet-Grill
|
|
Violation:
The wash hands often sign for the handwash station was posted on the paper towel dispenser that was located below the level of the handwash station, making it not visible to the crew members in the area.
|
|
Recommendation:
Ensure that a sign stating "WASH HANDS OFTEN" in a language that the food employees understand is posted over handwashing sinks.
|
|
|
Item No.:
20
|
|
Site:
Galley-Tall Pass-Through Refrigeration Units
|
|
Violation:
There was a seam at the lower edge of the glass panel on the inside of several tall pass-through refrigeration units in the passenger and crew galley,
|
|
Recommendation:
Ensure that materials used in the construction of food-contact surfaces of equipment are finished to have a smooth, easily cleanable surface.
|
|
|
Item No.:
20
|
|
Site:
Buffet-
|
|
Violation:
The milk dispensing tube was longer than one inch in length and not cut at an angle.
|
|
Recommendation:
Ensure that the bulk milk container dispensing tube is cut on the diagonal leaving no more than 25mm (1 inch) protruding from the chilled dispensing head.
|
|
|
Item No.:
22
|
|
Site:
Galley-Potwash
|
|
Violation:
The temperature gauge at the hot water sanitizing compartment of the three-compartment sink was indicating a temperature more than 20 °F higher than the temperature measured in the compartment. The sink was not in use at the time of the inspection.
|
|
Recommendation:
Ensure that warewashing equipment is maintained in good repair and proper adjustment including maintaining water pressure, and water temperature measuring devices in good repair and ensuring their accuracy within the intended range of use.
|
|
|
Item No.:
33
|
|
Site:
Provisions-Fresh Produce
|
|
Violation:
The coved profile strip was separating from the bulkhead at the left side of the entrance. The lower edge of the threshold in the same area was also bent.
|
|
Recommendation:
Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas, are maintained in good repair.
|
|
|
Item No.:
33
|
|
Site:
Provisions-Dairy
|
|
Violation:
Under the cooling unit on the far left bulkhead, the grouting was separating from the stainless steel coving.
|
|
Recommendation:
Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas, are maintained in good repair.
|
|
|
Item No.:
17
|
|
Site:
Provisions-Parasite Destruction Letter
|
|
Violation:
The letter for parasite destruction did not indicate which fish provided to the ship was frozen to the time and temperature indicated in the letter.
|
|
Recommendation:
Ensure that, if raw, raw-marinated, partially cooked, or marinated-partially cooked fish are served in ready-to-eat form and if the fish are frozen by a supplier, a written letter from the supplier which specifies the fish species involved and both the temperature to which the fish was frozen and the total time period at that temperature. If the supplier provides any of the same species to the vessel in a fresh state, there shall be some designation on the outer packaging for the parasite-free fish.
|
|
|
Item No.:
33
|
|
Site:
Bar-Casio Bar
|
|
Violation:
The deck was soiled under the counter at the speed rail on the port side of the bar. This area was previously cleaned.
|
|
Recommendation:
Ensure that decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, are cleaned as often as necessary.
|
|
|
Item No.:
33
|
|
Site:
Pantry-Atrium Bar
|
|
Violation:
The deck/bulkhead juncture was not coved in the bar pantry/storage area.
|
|
Recommendation: