Cruise Ship: Crystal Symphony Cruise Line: Crystal Cruises LTD Inspection Date: 03/09/2009 Inspection Score: 98
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 33
Site: Food Service General-Coving
Violation: There was no coving in many of the food preparation areas.
Recommendation: Ensure that bulkhead and deck junctures are coved (including galleys, pantries, deck/counter junctures at buffets, bars, waiter stations, and dining room work counters).
Item No.: 33
Site: Galley-Storage Locker
Violation: There were two holes in the rear bulkhead, making cleaning difficult.
Recommendation: Seal the holes.
Item No.: 20
Site: Galley-Ice Machine (Port)
Violation: The plastic cover to the ice cuber was rough (due to a previous repair), making cleaning difficult.
Recommendation: Replace the plastic cover.
Item No.: 33
Site: Galley-Cold Galley
Violation: The deck of the technical compartment was soiled. Recessed grout was also noted between deck tiles in this area.
Recommendation: Ensure that decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, are cleaned as often as necessary.
Item No.: 26
Site: Galley-Cold Galley
Violation: The previously cleaned juicer basket was soiled. This was corrected.
Recommendation: Ensure that food-contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 33
Site: Galley-Room Service Section (Cold Galley)
Violation: Loose, peeling sealant was noted on the deckhead.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas, are maintained in good repair.
Item No.: 33
Site: Galley-Room Service Section (Cold Galley)
Violation: Recessed and missing grout was noted around the stainless steel pad of the work table and the scuppers. The deck in the corner adjacent to the Blast Chiller was soiled with food debris. This area was previously cleaned.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning. Ensure that decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, are cleaned as often as necessary.
Item No.: 21
Site: Galley-Room Service Section (Cold Galley)
Violation: The sealant on the backplane of the tabletop meat slicer was deteriorated.
Recommendation: Replace or remove sealant.
Item No.: 33
Site: Galley-Hot Galley/Saucier Station
Violation: Recessed and missing grout was noted between deck tiles behind the combination oven.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
Item No.: 21
Site: Galley-Hot Galley/Saucier Station
Violation: The support bracket to the drain line to the single compartment sink was broken and was being secured with material that was not easily cleanable.
Recommendation: Repair the support bracket.
Item No.: 21
Site: Galley-Hot Galley/Entremetier
Violation: Peeling sealant was noted on the door to the technical compartment of the deep fat fryers. This was corrected.
Recommendation: Remove the peeling sealant.
Item No.: 34
Site: Galley-Hot Galley/Poissonier (Fish Station)
Violation: A leak was found in the steam line to the combination oven.
Recommendation: Ensure that a plumbing system in a food area is maintained in good repair.
Item No.: 21
Site: Galley-Hot Galley/Poissonier (Fish Station)
Violation: Loose, peeling sealant was found on some equipment in this area.
Recommendation: Remove the loose, peeling sealant.
Item No.: 21
Site: Galley-Soup Station
Violation: Excess sealant was found on the exteriors of some of the tilting steam kettles.
Recommendation: Remove the excess sealant.
Item No.: 21
Site: Galley-Pantry
Violation: Peeling labels were found on the chocolate warmer and the whip cream machine, making cleaning difficult.
Recommendation: Reattach or remove the peeling labels.
Item No.: 33
Site: Galley-Pantry Walk-in Refrigerator
Violation: Loose profile strips were found at the deckhead-bulkhead juncture.
Recommendation: Repair the loose porfile strips.
Item No.: 33
Site: Galley-Coffee Station
Violation: Standing water was noted on the deck. This was corrected.
Recommendation: Ensure that decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, are cleaned as often as necessary.
Item No.: 22
Site: Galley-Dishwash Area
Violation: The mounted final rinse pressure gauge on the in-use conveyor glasswasher, registered 30 psi.
Recommendation: Calibrate the final rinse pressure gauge.
Item No.: 21
Site: Galley-Coffee Station
Violation: The coating on the base of one of the coffee grinders was deteriorated, making cleaning difficult.
Recommendation: Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 33
Site: Galley-
Violation: Recessed grout was noted between deck tiles inside the walk-in refrigerator.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
Item No.: 33
Site: Buffet-Trident Grill
Violation: The deackhead above the service area was soiled.
Recommendation: Clean the deckhead.
Item No.: 33
Site: Buffet-Trident Grill
Violation: The decking in the technical compartment at the end of the service counter was rough, making cleaning difficult.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
Item No.: 33
Site: Buffet-Trident Grill
Violation: Recessed and missing grout was noted in this area.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
Item No.: 19
Site: Buffet-Trident Grill
Violation: Bowls of chips were stored on the service counter unprotected from possible contamination.
Recommendation: Ensure that food is protected from contamination by storing the food: (1) In a clean, dry location; (2) Where it is not exposed to splash, dust, or other contamination; and (3) At least 15 centimeters (6 inches) above the deck.
Item No.: 30
Site: Bar-Officer's Bar
Violation: The required "Wash Hands Often" sign was missing at the handwash station.
Recommendation: Install the required "Wash Hands Often" sign at this location.
Item No.: 24
Site: Buffet-Crew Mess
Violation: The sanitizer concentration inside the sanitizer container measured less than 50 ppm. This was corrected.
Recommendation: Ensure that a chlorine solution used as a sanitizing solution has a concentration between 50 mg/L (ppm) and 200 mg/L (ppm).
Item No.: 24
Site: Galley-
Violation: The sanitizer concentration inside the sanitizer container measured less than 50 ppm. This was corrected.
Recommendation: Ensure that a chlorine solution used as a sanitizing solution has a concentration between 50 mg/L (ppm) and 200 mg/L (ppm).
Item No.: 33
Site: Preparation Room-
Violation: Recessed and missing grout was noted between deck tiles in this area.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
Item No.: 33
Site: Galley-Pastry
Violation: The deck/bulkhead juncture in the baking area was not coved. This is a repeat item from the previous inspection.
Recommendation: Ensure that bulkhead and deck junctures are coved (including galleys, pantries, deck/counter junctures at buffets, bars, waiter stations, and dining room work counters).
Item No.: 17
Site: Galley-Cooling Logs
Violation: There was a column next to the 2-hour cooling temperature that was for recording the final time. This column was confusing, in that there were instances when the cooling process was continued after the final recorded time. On 04 March 2009, lobster broth was cooled to a temperature of 130 °F after 2-hours and then continued to be coolned to 39 ° after an additional 4-hours. On teh same day, "Steamed vegetables" were cooled from 170 °F to 120 °F after 2-hours and then continued to be cooled to less than 41°F The logs did not show that these foods were cooled from 140 °F to 70°F within 2-hours.
Recommendation:
Item No.: 08
Site: Potable Water-
Violation: The potable water hoses were not capped and were stored in an open bin that was less than 18 inches from the deck. This bin was the bin used to transport the hoses and was not intended for storage.
Recommendation: Ensure that potable water hoses are stowed rolled tight with the ends capped, on reels, or racks or with ends coupled together in potable water hose lockers.
Item No.: 10
Site: Recreational Water Facilities-Crew
Violation: There was no safety sign. There was no shepherd's hook. There was no rope attached to the floatation deivce.
Recommendation: Ensure that safety signs are provided for public swimming pools and whirlpool spas. Ensure that an easy-access shepherd's hook and approved floatation device (with a length of line 1/2 the pool width or 16 m (50 feet)) is provided at a prominent location near each public swimming pool.
Item No.: 10
Site: Recreational Water Facilities-Crew
Violation: The drain cover was loose.
Recommendation: Ensure that anti-entrapment drain covers are securely attached.
Item No.: 08
Site: Potable Water-
Violation: There were several days when it took more than 30 minutes to reach a minimum of 2.0 ppm after the start of bunkering.
Recommendation: Ensure that a minimum of 2.0 ppm is reached within 30 minutes after the start of bunkering.
Item No.: 08
Site: Potable Water-
Violation: None of the connections to the potable water system in the crew galley were listed in the cross-connection control program. All of the connections observed were adequately protected.
Recommendation: Ensure that the cross-connection control program includes at minimum: a complete listing of cross-connections and the backflow prevention method/device for each, so that there is a match to the plumbing system component and location, and an inspection frequency. Ensure that air-gaps are included in the listing.
*Inspections scores of 85 or lower are NOT satisfactory