|
|
|
Item No.:
33
|
|
Site:
Food Service General-Decks
|
|
Violation:
The decks in the galleys and bar pantries were difficult to clean due to cracks and chips, especially around equipment foundations, gutterways, thresholds, and deck/bulkhead junctures.
|
|
Recommendation:
Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
|
|
|
Item No.:
33
|
|
Site:
Buffet-Starboard Beach Blanket Buffet
|
|
Violation:
There were cables on the deck in the technical compartment below the juice machine.
|
|
Recommendation:
Secure the cables above the deck.
|
|
|
Item No.:
33
|
|
Site:
Galley-Pluto's
|
|
Violation:
Many of the deck/bulkhead junctures were not coved. The deck was damaged, causing a gap between the deck and the bulkhead near the handwash station.
|
|
Recommendation:
Ensure that bulkhead and deck junctures are coved (including galleys, pantries, deck/counter junctures at buffets, bars, waiter stations, and dining room work counters). Repair the damaged deck near the handwash station.
|
|
|
Item No.:
33
|
|
Site:
Galley-Pluto's
|
|
Violation:
In technical compartment ESP # 0965, there was peeling sealant on the right side deck/wall juncture and old, rough pipe insulation at the base of the deck penetration.
|
|
Recommendation:
Remove the peeling sealant and the old pipe insulation.
|
|
|
Item No.:
33
|
|
Site:
Buffet-Pinocchio's
|
|
Violation:
The deck/cabinet junctures were not coved.
|
|
Recommendation:
Ensure that bulkhead and deck junctures are coved (including galleys, pantries, deck/counter junctures at buffets, bars, waiter stations, and dining room work counters).
|
|
|
Item No.:
33
|
|
Site:
Galley-Palo's
|
|
Violation:
The deck/cabinet and deck/bulkhead junctures were not coved in all areas of the show galley. Some locations had coved tiles, but the coved surface was not flush with the deck tiles. Some areas of the back galley were also not coved.
|
|
Recommendation:
Ensure that bulkhead and deck junctures are coved (including galleys, pantries, deck/counter junctures at buffets, bars, waiter stations, and dining room work counters).
|
|
|
Item No.:
21
|
|
Site:
Buffet-Parrot Cay
|
|
Violation:
In technical compartment ESP #182, there were many cables with excess length. Some were coiled and secured and some coiled but just placed on lower supports of the compartment.
|
|
Recommendation:
Remove the excess cables and secure remaining cables above the deck.
|
|
|
Item No.:
22
|
|
Site:
Galley-Parrot Cay
|
|
Violation:
The data plate on the conveyor dishwash machine had the speed in plates per hour instead of the conveyor speed.
|
|
Recommendation:
Ensure that the data plate includes the conveyor speed.
|
|
|
Item No.:
33
|
|
Site:
Food Service General-Bains Marie
|
|
Violation:
The decks in the technical compartments for many of the bains marie units were very rough and had limited access for cleaning. Some of the decks were also soiled. The worst conditions were noted in Parrot Cay hot line, Parrot Cay kids line, and Triton hot line. The technical compartments below the Animator's hot line were also rough.
|
|
Recommendation:
Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning. Ensure that decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, are cleaned as often as necessary.
|
|
|
Item No.:
33
|
|
Site:
Galley-Parrot Cay
|
|
Violation:
The new deck material did not have a smooth transition to many of the equipment foundations and some of the deck junctures and gutterways.
|
|
Recommendation:
Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
|
|
|
Item No.:
21
|
|
Site:
Room Service-Bellbox
|
|
Violation:
There was a gap under the top edge of the front of the fryer.
|
|
Recommendation:
Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
27
|
|
Site:
Room Service-Bellbox
|
|
Violation:
The gap under the top edge of the front of the fryer was soiled with grease.
|
|
Recommendation:
Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
21
|
|
Site:
Pantry-Promenade Lounge
|
|
Violation:
In the technical compartment below the utility sink at the back bar counter, there was a gap along the floor of the compartment.
|
|
Recommendation:
Profile the gap.
|
|
|
Item No.:
36
|
|
Site:
Pantry-Diversions
|
|
Violation:
One of the light fixtures was out, resulting in lighting levels below 220 lux at the handwash station and the espresso machine.
|
|
Recommendation:
Repair or replace the light fixture.
|
|
|
Item No.:
33
|
|
Site:
Bar-Diversions
|
|
Violation:
The deck/cabinet juncture at the buffet was not coved.
|
|
Recommendation:
Ensure that bulkhead and deck junctures are coved (including galleys, pantries, deck/counter junctures at buffets, bars, waiter stations, and dining room work counters).
|
|
|
Item No.:
11
|
|
Site:
Medical-Asymptomatic Contacts
|
|
Violation:
Although there is documentation when there is or is not a cabin mate when crew gastrointestinal illness (GI) cases are reported, there is only documentation if there is an immediate contact for crew GI cases. There is no record made to indicate there are no immediate contacts.
|
|
Recommendation:
Ensure that the documentation includes whether or not the ill crew member has close contacts to be tracked for symptoms.
|
|
|
Item No.:
11
|
|
Site:
Medical-Asymptomatic Contacts
|
|
Violation:
The record of interviews for asymptomatic cabin mates and immediate contacts for the reported crew gastrointestinal illness (GI) cases was consistently done within 24 hours after onset of the ill crew members symptoms, but was not in the 48 hour after onset period. Additionally, when completing the form on isolation and release of GI cases and roommates/immediate contacts there were dates given for the asymptomatic cabin mates and immediate contacts under the title last GI symptom and release from isolation. These fields were completed on the form even though the roommate or immediate contact had no symptoms.
|
|
Recommendation:
Ensure that medical staff conduct daily verbal interviews with asymptomatic crew until 48 hours after onset of the ill crew members symptoms. Ensure that the forms are clear as to the symptom status of the asymptomatic contacts of crew members with gastrointestinal illness.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Flounders - Child Activity Area
|
|
Violation:
There was a non-continuous pressure backflow preventer installed on the hot and cold potable water supply pipes to the sink opposite the dishwash machine in the Flounders section of the nursery. The sink tap had a spray nozzle and hose after the device. These devices were not on the cross-connection control program list.
|
|
Recommendation:
Ensure that a continuous pressure-type backflow preventer is installed when a valve is located downstream from the backflow preventer. Ensure that the backflow preventers on the sink are included in the cross connection control program.
|
|
|
Item No.:
10
|
|
Site:
DO NOT USE (whirlpool/spa)-Whirlpool Spa Halogenation/Filtration
|
|
Violation:
A major modification made to the equipment and system of halogenation and filtration in all the whirlpool pump rooms included chlorine dosing of returned water from the whirlpool spa overflow in the compensation tank directly with no filtration until after passing thru the compensation tank and being pumped to a filter. Following filtration, there were ultraviolet light disinfection units installed, then heaters, then a return of this water to the whirlpool spa tubs. A potable water pipe meant for topping off the compensation tank had a direct connection to the pipe returning the filtered water to the whirlpool tub. The pipe leading to the compensation tank had the valve in the closed position. Lastly, the chlorine sample point was located after the compensation tank and before the filtration, UV treatment, and heater components.
|
|
Recommendation:
Ensure that the halogenation of the whirlpool water occurs after filtration, ultraviolet disinfection and heating of the water system. Organic material, ultraviolet light and heating will all reduce the amount of halogen in the water.
Ensure that the chlorine sample point is located prior to halogenation of the return water so that the sample will represent the water in the whirlpool. Ensure that when the whirlpool is in operation, the valves on the potable water filling line are positioned so that potable water will enter the compensation tank and be halogenated prior to entering the whirpool.
|
|