Item No.:
*
|
|
Site:
Potable Water-Medical - E. coli verification
|
|
Violation:
The ship does not have a working fluorescent light to check for E. coli using the Colisure test kit. Since the last inspection, all distribution system test results have been negative for total coliforms.
|
|
Recommendation:
Replace the damaged fluorescent light.
|
|
|
Item No.:
09
|
|
Site:
Recreational Water Facilities-Records
|
|
Violation:
The swimming pool records for Swimming Pool Deck E, did not list chlorine readings from 12/16/2008 (last measurement taken and recorded for the 0800-1200 period) until 12/31/2008. According to the ship's staff, the unit may not have been in service. However, the records do not indicate closure.
|
|
Recommendation:
Ensure that a free residual halogen of >1.0 and <5.0 mg/L (ppm) is maintained in recirculated swimming pools.
|
|
|
Item No.:
09
|
|
Site:
Recreational Water Facilities-Halogenation
|
|
Violation:
Swimming Pool E halogen level (chlorine) was measured at 0.00 and 0.01 ppm. The pool chlorine level was also tested using the ship's test equipment, with similar findings. The pool was not netted and there were passengers in the area of the open pool. Swimming Pool Deck G halogen level (chlorine) was measured at 0.22 ppm (inspector) and 0.21 ppm using the ship's equipment. The pool was not netted and there were passengers in the area of the open pool. Both pools were immediately closed (netted) until proper halogen levels were reached.
|
|
Recommendation:
Ensure that a free residual halogen of >1.0 and <5.0 mg/L (ppm) is maintained in recirculated swimming pools.
|
|
|
Item No.:
11
|
|
Site:
Medical-Medical Documentation
|
|
Violation:
There was no documentation of the time an ill crew member was cleared to return to work (The crew member was a waiter who became ill during the voyage ending 28 Feb 2009). In addition, there was no documentation of the follow-up of asymptomatic cabin mates and close contacts of the ill crew member. This is a repeat finding from the previous inspection.
|
|
Recommendation:
Document the time ill crew members are cleared to return to work. Document the follow-up of asymptomatic cabin mates and close contacts of ill crew members.
|
|
|
Item No.:
15
|
|
Site:
Galley-Mediterranea
|
|
Violation:
There was a can of chestnuts with severe dents along the top and bottom seams. This item was discarded.
|
|
Recommendation:
Ensure that food packages are in good condition and protect the integrity of the contents so that the food is not exposed to adulteration or potential contaminants. Ensure that canned goods with dents on end or side seams are not used.
|
|
|
Item No.:
16
|
|
Site:
Galley-Reach-in Refrigerator #5
|
|
Violation:
A large tray pan of cooked tomato sauce and vegetables were found with an internal product temperature of 69°F. This pan was prepared earlier in the morning and was immediately placed into the blast chiller for rapid cooling.
|
|
Recommendation:
Except during preparation, cooking, or cooling, or when time is used as the public health control, ensure that potentially hazardous food is maintained: (1) At 60°C (140°F) [roasts 54°C (130°F)] or above, or (2) At 5°C (41°F) or less.
|
|
|
Item No.:
17
|
|
Site:
Galley-Cooling Logs
|
|
Violation:
The cooling logs were very confusing with respect to documentation of the two-stage cooling process. The staff were unable to clearly explain the cooling process and the time-temperature requirements. The log was not designed in a way to allow logging of time and temperatures from 140 °F to 70 °F and from 70 °F and 41°F and below.
|
|
Recommendation:
Ensure the documentation of the tow-stage cooling process is clear and that the staff is properly trained in the cooling & documentation processes
|
|
|
Item No.:
18
|
|
Site:
Provisions-Meat Walk-in Refrigerator
|
|
Violation:
There was a large tray of raw chicken stored directly on top of a large container of cut beef steaks. Both containers were open.
|
|
Recommendation:
Ensure that food is protected from cross-contamination by: (2) Separating types of raw animal foods from each other such as beef, fish, lamb, pork, and poultry during storage, preparation, holding, and display by using separate equipment for each type, or arranging each type of food in equipment so that cross-contamination of one type with another is prevented, and preparing each type of food at different times or in separate areas.
|
|
|
Item No.:
18
|
|
Site:
Galley-Reach-in Refrigerator #10
|
|
Violation:
A large pan of raw chicken was stored uncovered on the shelf above a large pan of cooked pasta.
|
|
Recommendation:
Ensure that food is protected from cross-contamination by: (2) Separating types of raw animal foods from each other such as beef, fish, lamb, pork, and poultry during storage, preparation, holding, and display by using separate equipment for each type, or arranging each type of food in equipment so that cross-contamination of one type with another is prevented, and preparing each type of food at different times or in separate areas.
|
|
|
Item No.:
19
|
|
Site:
Provisions-Meat Walk-in Refrigerator
|
|
Violation:
Some of the cardboard containers with meat inside were soaked with blood and raw meat juices.
|
|
Recommendation:
Remove food items from saturated cardboard containers and place in clean non-absorbent containers.
|
|
|
Item No.:
19
|
|
Site:
Galley-Hot Galley
|
|
Violation:
A working container of salt was not labeled.
|
|
Recommendation:
Label the working container of salt.
|
|
|
Item No.:
19
|
|
Site:
Galley-Mediterranea
|
|
Violation:
Working containers of salt and sugar were not labeled.
|
|
Recommendation:
Label the working containers of salt and sugar.
|
|
|
Item No.:
20
|
|
Site:
Galley-Mediterranea
|
|
Violation:
Some of the metal water pitchers had peeling interior surfaces.
|
|
Recommendation:
Replace the metal water pitchers with peeling interior surfaces.
|
|
|
Item No.:
20
|
|
Site:
Pantry-Pacific Bar Pantry
|
|
Violation:
There was loose sealant on the underside of the ice cuber of the ice machine.
|
|
Recommendation:
Remove the loose sealant.
|
|
|
Item No.:
21
|
|
Site:
Other-Magellan Dining Room
|
|
Violation:
The racks inside the wine refrigerator were constructed of bare wood. This is a repeat item from the previous inspection.
|
|
Recommendation:
Ensure that nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material.
|
|
|
Item No.:
21
|
|
Site:
Galley-Magellan
|
|
Violation:
The technical compartment of the deep fat fryer was corroded and had gaps and other difficult to clean features.
|
|
Recommendation:
Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
21
|
|
Site:
Galley-Hot Galley
|
|
Violation:
There were missing fasteners on the underside of the grill, leaving gaps, making cleaning difficult.
|
|
Recommendation:
Replace the missing fasteners.
|
|
|
Item No.:
21
|
|
Site:
Galley-Hot Section (Kettles)
|
|
Violation:
The underside of the tilting pans are not easy to clean due to gaps and other difficult to clean features. These items are due for replacement in 30 days.
|
|
Recommendation:
Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
21
|
|
Site:
Galley-Hot Section (Kettles)
|
|
Violation:
The tilting kettle was posted out of order. The unit is to be replaced in 30 days.
|
|
Recommendation:
Replace the tilting pan.
|
|
|
Item No.:
21
|
|
Site:
Buffet-Mediterranean
|
|
Violation:
The coating on the top of the fan unit inside the technical compartment of the juice machine was peeling, making cleaning difficult.
|
|
Recommendation:
Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
21
|
|
Site:
Pantry-Crew Mess Pantry
|
|
Violation:
The two-burner hot plate was corroded, had missing fasteners resulting in gaps, making cleaning difficult.
|
|
Recommendation:
Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
22
|
|
Site:
Galley-Mediterranea Dishwash Area
|
|
Violation:
One of the upper final rinse spray nozzles on the in-use conveyor dishwasher was clogged. This item was corrected.
|
|
Recommendation:
Ensure that warewashing equipment is maintained in good repair and proper adjustment including: (1) Being maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; and (2) Maintaining water pressure, and water temperature measuring devices in good repair and ensuring their accuracy within the intended range of use.
|
|
|
Item No.:
26
|
|
Site:
Galley-Mediterranea
|
|
Violation:
A few soiled glasses were found in the dishracks in this area.
|
|
Recommendation:
Ensure that food-contact surfaces of equipment and utensils are clean to sight and touch.
|
|
|
Item No.:
26
|
|
Site:
Galley-Hot Galley
|
|
Violation:
The blade section of the large hand-held mixer was soiled and stored as clean.
|
|
Recommendation:
Ensure that food-contact surfaces of equipment and utensils are clean to sight and touch.
|
|
|
Item No.:
26
|
|
Site:
Other-Magellan
|
|
Violation:
A couple of soiled plates were stored inside the clean storage cabinet.
|
|
Recommendation:
Ensure that food-contact surfaces of equipment and utensils are clean to sight and touch.
|
|
|
Item No.:
26
|
|
Site:
Other-Magellan
|
|
Violation:
The clean utensil tray was soiled with food particles. No clean items were stored inside at the time of the inspection.
|
|
Recommendation:
Ensure that food-contact surfaces of equipment and utensils are clean to sight and touch.
|
|
|
Item No.:
26
|
|
Site:
Pantry-Pacific Bar Pantry Ice Machine
|
|
Violation:
There was a small amount of a black, mold-like substance on the bottom side of the ice cuber.
|
|
Recommendation:
Ensure that food-contact surfaces of equipment and utensils are clean to sight and touch.
|
|
|
Item No.:
26
|
|
Site:
Galley-Bakery
|
|
Violation:
The floor-model mixer canopy (top portion) was soiled with old, dried food residue.
|
|
Recommendation:
Ensure that food-contact surfaces of equipment and utensils are clean to sight and touch.
|
|
|
Item No.:
27
|
|
Site:
Galley-Hot Section (Kettles)
|
|
Violation:
The underside of the tilting pans were soiled with old food debris.
|
|
Recommendation:
Clean the underside of the tilting pan.
|
|
|
Item No.:
27
|
|
Site:
Galley-Magellan
|
|
Violation:
The underside of the deep fat fryer was heavily soiled with grease and food debris. This item was corrected.
|
|
Recommendation:
Clean the underside of the deep fat fryer.
|
|
|
Item No.:
27
|
|
Site:
Pantry-Crew Mess Pantry
|
|
Violation:
The underside of the two-burner hot plate was soiled with old food debris.
|
|
Recommendation:
Clean the underside of the two-burner hot plate.
|
|
|
Item No.:
27
|
|
Site:
Pantry-Crew Mess Pantry
|
|
Violation:
The countertop beneath the two-burner hot-plate was soiled with old food debris.
|
|
Recommendation:
Clean the countertop beneath the two-burner hot plate.
|
|
|
Item No.:
27
|
|
Site:
Galley-Magellan
|
|
Violation:
The stainless steel tabletop under the grill section was soiled with old food and grease. This item was corrected.
|
|
Recommendation:
Clean the tabletop under the grill section.
|
|
|
Item No.:
27
|
|
Site:
Galley-Magellan All-Purpose Room
|
|
Violation:
The soda machine lines were soiled. This unit is awaiting removal by the Coca Cola Company (leased equipment).
|
|
Recommendation:
Clean the soda machine lines.
|
|
|
Item No.:
27
|
|
Site:
Galley-Hot Galley
|
|
Violation:
The metal cling wrap dispenser was soiled with old food debris.
|
|
Recommendation:
Clean the metal cling wrap dispenser.
|
|
|
Item No.:
27
|
|
Site:
Galley-Mediterranea
|
|
Violation:
There was standing liquid in the bottom of the technical compartment of the deep fat fryer.
|
|
Recommendation:
Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
28
|
|
Site:
Galley-Mediterranea
|
|
Violation:
A fryer basket was stored directly on the deck behind the deep fat fryer. This item was corrected.
|
|
Recommendation:
Ensure that cleaned equipment and utensils, laundered linens, and single-service and single-use articles are stored: (1) In a clean, dry location; (2) Where they are not exposed to splash, dust, or other contamination; and (3) At least 150 mm (6 inches) above the deck.
|
|
|
Item No.:
28
|
|
Site:
Buffet-Mediterranea (Starboard/Forward)
|
|
Violation:
A large bowl was found stored with water in the interior surfaces. This item was previously cleaned.
|
|
Recommendation:
Ensure that clean equipment and utensils are stored: (1) In a self-draining position that allows air drying; and (2) Covered or inverted.
|
|
|
Item No.:
28
|
|
Site:
Galley-Magellan
|
|
Violation:
Clean plates and other items were stored wet.
|
|
Recommendation:
Ensure that clean equipment and utensils are stored: (1) In a self-draining position that allows air drying; and (2) Covered or inverted.
|
|
|
Item No.:
28
|
|
Site:
Galley-Potwash Area
|
|
Violation:
Several previously cleaned hotel pans were stored in a manner that impeded proper air drying.
|
|
Recommendation:
Ensure that clean equipment and utensils are stored: (1) In a self-draining position that allows air drying; and (2) Covered or inverted.
|
|
|
Item No.:
28
|
|
Site:
Pantry-Crew Mess Pantry
|
|
Violation:
There were a few previously cleaned utensils found soiled and stored with clean utensils.
|
|
Recommendation:
Ensure that cleaned equipment and utensils, laundered linens, and single-service and single-use articles are stored: (1) In a clean, dry location; (2) Where they are not exposed to splash, dust, or other contamination; and (3) At least 150 mm (6 inches) above the deck.
|
|
|
Item No.:
30
|
|
Site:
Galley-Hot Galley
|
|
Violation:
The soap dispenser was clogged. This item was corrected.
|
|
Recommendation:
Ensure that handwashing facilities are kept clean and in good repair.
|
|
|
Item No.:
33
|
|
Site:
Food Service General-Decks and Bulkheads
|
|
Violation:
There was recessed and missing grout especially along the scuppers. There were cracked and broken deck tiles and tile coving. There were profile strips that were not flush with the bulkhead, especially at the bottom edges. This is repeat item from the previous inspection. Some of the decks inside the technical spaces were rough, making cleaning difficult.
|
|
Recommendation:
Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
|
|
|
Item No.:
33
|
|
Site:
Pantry-Moby Dick Bar Pantry
|
|
Violation:
The base of the door was damaged, making cleaning difficult.
|
|
Recommendation:
Repair the damaged door.
|
|
|
Item No.:
33
|
|
Site:
Buffet-Mediterranean
|
|
Violation:
Rough grout was noted on the interior, lower surface of the technical compartment of the juice machine, making cleaning difficult.
|
|
Recommendation:
Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
|
|
|
Item No.:
33
|
|
Site:
Buffet-Mediterranea (Starboard/Forward)
|
|
Violation:
The technical compartments beneath the buffet were soiled and difficult to clean.
|
|
Recommendation:
Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
|
|
|
Item No.:
33
|
|
Site:
Galley-Mediterranea
|
|
Violation:
Peeling soft sealant was found at the deck-bulkhead juncture of elevator #3
|
|
Recommendation:
Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
|
|
|
Item No.:
33
|
|
Site:
Buffet-Mediterranean
|
|
Violation:
There were peeling surfaces on the deck inside the technical compartment of the bain maries, making cleaning difficult.
|
|
Recommendation:
Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
|
|
|
Item No.:
33
|
|
Site:
Buffet-Crew Mess
|
|
Violation:
The technical compartment beneath the bain marie had a rough surface, making cleaning difficult. There was standing water on the deck on the service side of the buffet.
|
|
Recommendation:
Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning. Ensure that decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, are cleaned as often as necessary.
|
|
|
Item No.:
33
|
|
Site:
Buffet-
|
|
Violation:
There was no coving at the deck-equipment juncture at the buffet or beverage stations. This is a repeat item from the previous inspection.
|
|
Recommendation:
Ensure that bulkhead and deck junctures are coved (including galleys, pantries, deck/counter junctures at buffets, bars, waiter stations, and dining room work counters).
|
|
|
Item No.:
38
|
|
Site:
Other-Magellan Dining Room
|
|
Violation:
The soda machine has not been used for at least one year. This item is scheduled for removal.
|
|
Recommendation:
Ensure that only articles necessary for the food service operation are stored in food preparation, food storage, and warewashing areas.
|
|
|
Item No.:
39
|
|
Site:
Buffet-Mediterranean
|
|
Violation:
Several drain flies were found on the interior of the technical compartment of the soda machine.
|
|
Recommendation:
Ensure that the presence of insects, rodents, and other pests is effectively controlled to minimize their presence in the food storage, preparation, service areas, warewashing, and utensil storage areas aboard a vessel.
|
|
|
Item No.:
39
|
|
Site:
Buffet-Mediterranea (Starboard/Forward)
|
|
Violation:
A few drain flies were found inside the technical compartment of the buffet station.
|
|
Recommendation:
Ensure that the presence of insects, rodents, and other pests is effectively controlled to minimize their presence in the food storage, preparation, service areas, warewashing, and utensil storage areas aboard a vessel.
|
|
|
Item No.:
39
|
|
Site:
Buffet-Mediterranea (Starboard/Forward)
|
|
Violation:
Two live drain flies were noted in this area.
|
|
Recommendation:
Ensure that the presence of insects, rodents, and other pests is effectively controlled to minimize their presence in the food storage, preparation, service areas, warewashing, and utensil storage areas aboard a vessel.
|
|
|
Item No.:
40
|
|
Site:
Integrated Pest Management-IPM Program
|
|
Violation:
The written IPM Plan did not reflect the actual logs and procedures used by the staff onboard the vessel. There were no documented night inspections. The listing of MSDS was incomplete.
|
|
Recommendation:
Ensure that each vessel develops an Integrated Pest Management Plan to address effective monitoring and control strategies for pests aboard the vessel. Ensure that the Integrated Pest Management Plan establishs health and safety procedures to protect the passengers and crew.
|
|
|
Item No.:
41
|
|
Site:
Ventilation-Ventilation Air Handling Units
|
|
Violation:
There were 7-8 air handling units in which the condensate collection drain pans could not be accessed for inspection. The ship is attempting to install inspection/cleaning ports to these units. This is a repeat finding from the previous inspection.
|
|
Recommendation:
Ensure that air handling unit condensate drain pans and collection systems are accessible for inspection, maintenance, and cleaning.
|
|
|
Item No.:
41
|
|
Site:
Medical-Medical - Fogging Chemical
|
|
Violation:
The ship is using Aspeanios Terminal HPH as the chenical for fogging public areas and cbins with AGE cases. There is no indication that the chemical is effective against either Feline Calicivirus or Murine Norovirus. Therefore, it could not be derermined if the chemical was effective against noroviruses.
|
|
Recommendation:
Ensure disinfectants are effective against either Feline Calicivirus or Murine Norovirus, both of which are appropriate tests for noroviruses.
|
|