Item No.:
21
|
|
Site:
Buffet-
|
|
Violation:
There was a cracked light shield above the hot food line, making cleaning difficult.
|
|
Recommendation:
Replace the cracked light shield.
|
|
|
Item No.:
30
|
|
Site:
Galley-Hand Wash Stations
|
|
Violation:
Warewash detergent was noted inside the soap dispensers at all of the hand wash stations in the lido galley and buffet.
|
|
Recommendation:
Ensure that handwashing soap is used in the soap dispensers at the handwash stations.
|
|
|
Item No.:
27
|
|
Site:
Galley-Dish Wash Area
|
|
Violation:
The non-food contact surfaces inside the upper compartment of the ice machine were slightly soiled.
|
|
Recommendation:
Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Cross-Connection Control Program
|
|
Violation:
The backflow prevention device for the dialysis tanks and one air gap were not listed on the Cross-Connection Control list.
|
|
Recommendation:
Ensure that the cross-connection control program includes at minimum: a complete listing of cross-connections and the backflow prevention method/device for each, so that there is a match to the plumbing system component and location, and an inspection frequency. Ensure that air-gaps are included in the listing.
|
|
|
Item No.:
10
|
|
Site:
DO NOT USE (whirlpool/spa)-Records
|
|
Violation:
The chlorine residual was tested hourly but only recorded every 4 hours. A mark in the log noted that the chlorine residual was checked hourly, but no value was recorded.
|
|
Recommendation:
Ensure that residual halogen logs are maintained with residuals measured and recorded hourly during operation.
|
|
|
Item No.:
10
|
|
Site:
DO NOT USE (whirlpool/spa)-
|
|
Violation:
The drain cover did not have either the plumbing/engineering approving organization stamp or flow rate affixed to it. There was no letter maintained on board the vessel certifying the cover meets the safety requirements.
|
|
Recommendation:
Ensure that anti-entrapment drain covers or other drains that prevent entrapment hazards as specified in U.S. Consumer Product Safety Publication 363-009801 (dual drains/channel drains) are provided on swimming pools and whirlpool spas. Ensure that drain covers have either the plumbing/engineering approving organization stamp and flow rate affixed to the cover, or that a letter is maintained aboard the vessel certifying that the cover meets the safety requirements outlined in AMSE/ANSI A112.19.8M or an equivalent standard.
|
|
|
Item No.:
41
|
|
Site:
Ventilation-
|
|
Violation:
The air conditioning condensate collection pans were not accessible for inspection. This was a repeat violation from the previous inspection.
|
|
Recommendation:
Install a small hatch or window to view the condensate collection pan for inspection or obtain a fiber-optic camera to conduct inspections. Ensure that air handling unit condensate drain pans and collection systems are accessible for inspection, maintenance, and cleaning.
|
|
|
Item No.:
08
|
|
Site:
Galley-Hot Galley
|
|
Violation:
There was a non-continuous pressure backflow prevention device installed on the potable water line to the counter-mounted combination oven located between the fish and meat preparation rooms. There did not appear to be any backflow prevention device on the potable water line to the counter mounted combination oven located near the soup station.
|
|
Recommendation:
Ensure that a continuous pressure-type backflow preventer is installed when a valve is located downstream from the backflow preventer.
|
|
|
Item No.:
24
|
|
Site:
Galley-Dishwash
|
|
Violation:
At the flight-type dishwash unit, the dish surface was measured at 202°F, the temperature gauge indicated 220°F, and there was a large amount of steam visible at the final rinse spray nozzles. A service report indicated that this unit had been inspected by a Hobart technician on 12/14/06 and no problems were noted.
|
|
Recommendation:
In a mechanical operation, ensure that the temperature of the fresh hot water sanitizing rinse as it enters the manifold is not more than 90°C (194°F), or less than: (1) For a stationary rack, single temperature machine, 74°C (165°F); or (2) For all other machines, 82°C (180°F); or (3) A utensil surface temperature of 71°C (160°F) as measured by an irreversible registering temperature indicator shall be achieved. (4) The maximum temperature of 90°C (194°F), does not apply to the high pressure and temperature systems with wand-type, hand-held, spraying devices used for the in-place cleaning and sanitizing of equipment such as meat saws.
|
|
|
Item No.:
21
|
|
Site:
Galley-Dishwash
|
|
Violation:
There were milk-crate-like containers used to store plates in the clean dish storage area. The containers had ledges, crevices, and some rough surfaces that were difficult to clean. The staff stated that the plates were delivered to the vessel in these containers.
|
|
Recommendation:
Remove these containers from the food service area.
|
|
|
Item No.:
33
|
|
Site:
Food Service General-Deck Coving
|
|
Violation:
The deck/bulkhead and deck/cabinet junctures were not coved at waiter stations, buffets, and bars throughout the vessel. This is a new requirement in the 2005 VSP Operations Manual and this is the vessel's first inspection under the new manual.
|
|
Recommendation:
Ensure that bulkhead and deck junctures are coved (including galleys, pantries, deck/counter junctures at buffets, bars, waiter stations, and dining room work counters).
|
|
|
Item No.:
33
|
|
Site:
Buffet-Officer Mess and Crew Mess
|
|
Violation:
There was soft sealant at the deck junctures around the buffet counter in the officer mess and crew mess.
|
|
Recommendation:
Remove the soft sealant and replace with hard or semi-hard sealant that is durable and easy to clean.
|
|
|
Item No.:
17
|
|
Site:
Provisions-
|
|
Violation:
The letter from the supplier of the cold smoked salmon did not specify the time and temperature the fish was frozen to for parasite destruction. Freezing for parasite destruction did not occur onboard.
|
|
Recommendation:
Ensure that, if raw, raw-marinated, partially cooked, or marinated-partially cooked fish are served in ready-to-eat form: (1) The person in charge records the freezing temperature and time to which the fish are subjected and retains the records on the vessel for 90 calendar days beyond the time of service or sale of the fish; or (2) If the fish are frozen by a supplier, a written letter from the supplier which specifies the fish species involved and both the temperature to which the fish was frozen and the total time period at that temperature. If the supplier provides any of the same species to the vessel in a fresh state, there shall be some designation on the outer packaging for the parasite-free fish.
|
|
|
Item No.:
02
|
|
Site:
Medical-
|
|
Violation:
There were no shipping labels for shipping diagnostic samples. This is a new requirement in the 2005 VSP Operations Manual and this is the vessel's first inspection under the new manual.
|
|
Recommendation:
Ensure that at least 10 clinical specimen collection containers for both viral and bacteriological agents (10 each), as well as the proper shipping containers and labels for same, are maintained by the medical staff.
|
|
|
Item No.:
40
|
|
Site:
Integrated Pest Management-
|
|
Violation:
There was no documentation of the pest inspections of incoming shipments of food and supplies. This is a new requirement in the 2005 VSP Operations Manual and this is the vessel's first inspection under the new manual.
|
|
Recommendation:
Ensure that incoming shipments of food and supplies are routinely inspected for evidence of insects, rodents, and other pests. A record of these inspections shall be maintained onboard the vessel and shall be available for review during inspections.
|
|