Skip directly to site content Skip directly to page options

Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: Carnival Legend Cruise Line: Carnival Cruise Lines, Inc. Inspection Date: 10/31/2006 Inspection Score: 98
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 33
Site: Other-Supper Club
Violation: On the port side waiter station, the cove piece was missing along center part of the deck juncture, making cleaning difficult.
Recommendation: Ensure that bulkhead and deck junctures are coved (including galleys, pantries, deck/counter junctures at buffets, bars, waiter stations, and dining room work counters).
Item No.: 21
Site: Galley-Buffet Preparation
Violation: The rubber foot on the slicer was torn, making cleaning difficult.
Recommendation: Repair or replace the rubber foot on the slicer.
Item No.: 21
Site: Galley-Pastry
Violation: The covering on several handles to the bakery ovens were damaged, making cleaning difficult. All of the handles were replaced during the inspection.
Recommendation: Ensure that the handles remain easy to clean and are replaced as necessary.
Item No.: 27
Site: Food Service General-
Violation: The edges and the back area of the floor of multiple technical compartments throughout the galley were soiled with a black material. In the crew galley, a slight amount of soilage was noted. This was not noted in the bars that were inspected.
Recommendation: Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 37
Site: Galley-Pot Wash
Violation: Water was noted dripping from the deckhead onto a shelf in the clean pot storage area. This was noted during the last inspection. Engineering personnel have investigated the condensation problem and are looking into a solution. Due to the situation, there was no storage on the shelf under the dripping water.
Recommendation: Ensure that all food preparation, warewashing, and toilet rooms have sufficient ventilation to keep them free of excessive heat, steam, condensation, vapors, obnoxious odors, smoke, and fumes. Ensure that pots and pans are not stored in this area until the condensation problem is corrected.
Item No.: 22
Site: Galley-Pot Wash
Violation: The sanitizing compartment water was measured at 176°F, but the installed thermometer indicated 190°F.
Recommendation: Ensure that water temperature measuring devices: (1) That are scaled in Celsius or dually scaled in Celsius and Fahrenheit are designed to be accurate to ±1.5°C in the intended range of use. (2) That are scaled only in Fahrenheit are designed to be accurate to ±3°F in the intended range of use.
Item No.: 30
Site: Other-Garbage Room
Violation: There was no "wash hands often" sign at the handwashing station. This was corrected during the inspection.
Recommendation: Ensure that a sign stating "WASH HANDS OFTEN" in a language that the food employees understand is posted over handwashing sinks.
Item No.: 30
Site: Pantry-Crew Bar
Violation: There was no "wash hands often" sign at the handwashing station. This was corrected during the inspection.
Recommendation: Ensure that a sign stating "WASH HANDS OFTEN" in a language that the food employees understand is posted over handwashing sinks.
Item No.: 36
Site: Bar-Atlantis and Lobby Bars
Violation: It appeared that the lights in the glass fixtures of the chandeliers above the service area of the Lobby Bar and the Atlantis Bar were not shatter resistant.
Recommendation: Ensure that light bulbs are shielded, coated, or otherwise shatter-resistant in areas where there is exposed food, clean equipment, utensils, and linens, or unwrapped single-service and single-use articles.
Item No.: 24
Site: Buffet-Lido Buffet Starboard Side
Violation: The sanitizing solution for the three bucket system was measured at less than 50 PPM. This bucket was removed and replaced with a new sanitizing solution.
Recommendation: Ensure that a chlorine solution used as a sanitizing solution has a concentration between 50 mg/L (ppm) and 200 mg/L (ppm).
Item No.: 37
Site: Galley-
Violation: The ambient air temperature was measured at 96°F at the soiled end of the flight type dishwash machine. This area was in active use and was very hot and humid. The ventilation system did not appear to be working properly.
Recommendation: Ensure that all food preparation, warewashing, and toilet rooms have sufficient ventilation to keep them free of excessive heat, steam, condensation, vapors, obnoxious odors, smoke, and fumes.
Item No.: 21
Site: Food Service General-Clean Storage
Violation: Several waiter trays were chipped and peeling around the edges, making cleaning difficult. The wire rim was exposed on several trays in the lido area. This was noted on the previous inspection.
Recommendation: Replace the damaged waiter trays.
Item No.: 22
Site: Galley-Pot Wash
Violation: The sanitizing solution for the three compartment sink was measured at 180°F. The mounted thermometer indicated a temperature of 191°F. All thermometers were calibrated during the inspection.
Recommendation: Ensure that water temperature measuring devices: (1) That are scaled in Celsius or dually scaled in Celsius and Fahrenheit are designed to be accurate to ±1.5°C in the intended range of use. (2) That are scaled only in Fahrenheit are designed to be accurate to ±3°F in the intended range of use.
Item No.: 33
Site: Galley-Soup Area
Violation: Slight recessed grout was noted in this area, making cleaning difficult.
Recommendation: Repair the recessed grout.
Item No.: 33
Site: Galley-Soup Area
Violation: A gap was noted in the deckhead panel above combination oven 4811.011.541, making cleaning difficult.
Recommendation: Repair the deckhead panel.
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program