Item No.:
19
|
|
Site:
Buffet-Lido
|
|
Violation:
The handle surface of one pair of tongs was noted in direct contact with a fish dish.
|
|
Recommendation:
During pauses in food preparation or dispensing, ensure that food preparation and dispensing utensils are stored: (1) In the food with their handles above the top of the food and the container.
|
|
|
Item No.:
33
|
|
Site:
Galley-Tilting Pan Area
|
|
Violation:
Mild recessed grouting was noted in front of the tilting pans, making cleaning difficult.
|
|
Recommendation:
Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
|
|
|
Item No.:
22
|
|
Site:
Galley-Deck 1
|
|
Violation:
The mounted thermometer for the hot water sanitizing solution in the pot wash was out of calibration by 12°C. The final sanitizing temperature was measured at greater than 171°F during the inspection.
|
|
Recommendation:
Ensure that water temperature measuring devices: (1) That are scaled in Celsius or dually scaled in Celsius and Fahrenheit are designed to be accurate to ±1.5°C in the intended range of use. (2) That are scaled only in Fahrenheit are designed to be accurate to ±3°F in the intended range of use.
|
|
|
Item No.:
27
|
|
Site:
Galley-Deck A
|
|
Violation:
Numerous previously cleaned serving trays were soiled and stored as clean. All items were re-washed.
|
|
Recommendation:
Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
27
|
|
Site:
Buffet-Staff Mess
|
|
Violation:
Several previously cleaned serving trays were soiled and set out for service.
|
|
Recommendation:
Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
26
|
|
Site:
Buffet-Staff Mess
|
|
Violation:
A few previously cleaned plates were soiled and set out for service.
|
|
Recommendation:
Ensure that food-contact surfaces of equipment and utensils are clean to sight and touch.
|
|
|
Item No.:
29
|
|
Site:
Pantry-Deck 2 Dining Room
|
|
Violation:
The handwash station was blocked by a large waste receptacle. This was corrected.
|
|
Recommendation:
Ensure that handwashing facilities are used for no other purpose and are accessible at all times.
|
|
|
Item No.:
29
|
|
Site:
Pantry-Deck 2 Dining Room
|
|
Violation:
Coffee grounds were noted in the handwash sink.
|
|
Recommendation:
Ensure that handwashing facilities are used for no other purpose and are accessible at all times.
|
|
|
Item No.:
20
|
|
Site:
Pantry-Deck 2 Dining Room
|
|
Violation:
The ambient air temperature of the walk-in refrigerator was measured at 50°F. The ambient air temperature thermometer read 38°F. Staff performed daily temperature checks of the unit, however the temperature of the thermometer was recorded and not the internal temperature of the food items. One pan of butter was noted in this unit. The unit was placed under service and the butter was thrown out.
|
|
Recommendation:
Ensure that equipment for cooling and heating food, and holding cold and hot food, is sufficient in number and capacity to maintain specified potentially hazardous food temperatures.
|
|
|
Item No.:
16
|
|
Site:
Pantry-Deck 2 Dining Room
|
|
Violation:
One pan of individually wrapped butter packets was measured with an internal temperature of 47°F to 52°F in the walk-in refrigerator. This item was in the unit overnight and was discarded during the inspection.
|
|
Recommendation:
Except during preparation, cooking, or cooling, or when time is used as the public health control, ensure that potentially hazardous food is maintained: (1) At 60°C (140°F) [roasts 54°C (130°F)] or above, or (2) At 5°C (41°F) or less.
|
|
|
Item No.:
21
|
|
Site:
Pantry-Deck 2 Dining Room
|
|
Violation:
The ambient air temperature thermometer for the walk-in refrigerator was out of calibration. The ambient air temperature was measured at 50°F during the inspection while the thermometer measured 38°F. The unit was placed under service.
|
|
Recommendation:
Ensure that ambient air temperature measuring devices: (1) That are scaled in Celsius or dually scaled in Celsius and Fahrenheit are designed to be easily readable and accurate to ±1.5°C in the intended range of use. (2) That are scaled only in Fahrenheit are accurate to ±3°F in the intended range of use.
|
|