Cruise Ship: Seven Seas Voyager Cruise Line: Regent Seven Seas Inspection Date: 01/09/2007 Inspection Score: 95
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 06
Site: Potable Water-
Violation: The analyzer chart recorder on the bridge was not functioning properly. This unit had been placed out of order since 12/29/06. The technician was on the vessel to adjust the unit. Per the technician, the issue with the unit was the high pH level of the water.
Recommendation: Ensure that repairs on malfunctioning halogen analyzer-chart recorders are completed within 10 days of equipment failure.
Item No.: 08
Site: Potable Water-
Violation: Only one pressure reading was recorded for the reduced pressure backflow protection devices.
Recommendation: Keep a record of the pressure differential readings for each valve when testing the reduced pressure backflow prevention assemblies.
Item No.: 10
Site: Recreational Water Facilities-
Violation: The fecal accident procedure that was posted in the pump room did not address loose stools. The chlorine level to be used was 50 ppm for 60 minutes.
Recommendation: Ensure that a fecal accident response procedure, which meets or exceeds the procedure provided in annex 13.11, is documented and available to the VSP for review during inspections.
Item No.: 10
Site: Recreational Water Facilities-Crew Pool
Violation: There was no indication on the drain cover that it was anti-entrapment. A letter was not available indicating that the drain cover was anti-entrapment.
Recommendation: Ensure that anti-entrapment drain covers or other drains that prevent entrapment hazards as specified in U.S. Consumer Product Safety Publication 363-009801 (dual drains/channel drains) are provided on swimming pools and whirlpool spas. Ensure that drain covers have either the plumbing/engineering approving organization stamp and flow rate affixed to the cover, or that a letter is maintained aboard the vessel certifying that the cover meets the safety requirements outlined in AMSE/ANSI A112.19.8M or an equivalent standard.
Item No.: 18
Site: Provisions-Meat Freezer
Violation: There were trays of raw hamburger stored above trays of raw venison and rabbit.
Recommendation: Ensure that food is protected from cross-contamination by: (2) Separating types of raw animal foods from each other such as beef, fish, lamb, pork, and poultry during storage, preparation, holding, and display by using separate equipment for each type, or arranging each type of food in equipment so that cross-contamination of one type with another is prevented, and preparing each type of food at different times or in separate areas.
Item No.: 20
Site: Food Service General-
Violation: Slotted fasteners were noted in the ice/water contact surfaces of the upper compartments of the ice machines, making cleaning difficult.
Recommendation: Ensure that multiuse food-contact surfaces are: (1) Smooth; (2) Free of breaks, open seams >1 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices; (4) Finished to have smooth welds and joints; and (5) Accessible for cleaning and inspection by one of the following methods without being disassembled, by disassembling without the use of tools, or by easy disassembling with the use of handheld tools commonly available to maintenance and cleaning personnel such as screwdrivers, pliers, open-end wrenches, and Allen wrenches.
Item No.: 20
Site: Galley-Bakery
Violation: The proofer was posted out of order for over 1 year. Staff stated the manufacturer went out of business and they were looking for spare parts.
Recommendation: Repair the proofer or remove it if it will not be used.
Item No.: 22
Site: Galley-Portside Dishwash Machine
Violation: The right rinse spray nozzle was clogged.
Recommendation: Ensure that warewashing equipment is maintained in good repair and proper adjustment including: (1) Being maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; and (2) Maintaining water pressure, and water temperature measuring devices in good repair and ensuring their accuracy within the intended range of use.
Item No.: 22
Site: Galley-Dishwash
Violation: The right final rinse spray nozzle was partially clogged, causing an irregular spray pattern.
Recommendation: Ensure that warewashing equipment is maintained in good repair and proper adjustment including: (1) Being maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; and (2) Maintaining water pressure, and water temperature measuring devices in good repair and ensuring their accuracy within the intended range of use.
Item No.: 27
Site: Other-The Grill
Violation: Grease was noted on the undersurface of the grill.
Recommendation: Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 28
Site: Buffet-Verandah Cafe
Violation: The wiping cloth and sponges were stored on the bottom surfaces of inverted buckets. When in use the buckets were kept on the deck.
Recommendation: Ensure the wiping cloth and sponges are stored on a clean surface.
Item No.: 28
Site: Galley-Dishwash
Violation: Condensate was noted dripping from the deckhead onto the clean plates on the clean landing. The machine was in active use during the inspection. The plates were rewashed.
Recommendation: Ensure that clean equipment and utensils are not exposed to splash or other contamination.
Item No.: 28
Site: Galley-Hot Galley
Violation: A cutting board and a ladle were located inside the technical compartment under the baine marie.
Recommendation: Ensure that cleaned equipment and utensils, laundered linens, and single-service and single-use articles are stored: (1) In a clean, dry location; (2) Where they are not exposed to splash, dust, or other contamination; and (3) At least 150 mm (6 inches) above the deck.
Item No.: 28
Site: Galley-Starboard Side Coffee Station
Violation: The juice containers and lids were stored inverted on a wet shelf inside the storage cabinet under the bread slicer.
Recommendation: Ensure that cleaned equipment and utensils, laundered linens, and single-service and single-use articles are stored: (1) In a clean, dry location; (2) Where they are not exposed to splash, dust, or other contamination; and (3) At least 150 mm (6 inches) above the deck.
Item No.: 33
Site: Pantry-Horizon Lounge
Violation: The grout was worn, making cleaning difficult.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
Item No.: 36
Site: Bar-Horizon Lounge
Violation: The undercounter lights were not working resulting in insufficient light levels for cleaning purposes.
Recommendation: Ensure that the light intensity is at least 220 Lux (20 foot candles) in bars and at dining room waiter stations during periods of cleaning.
Item No.: 37
Site: Galley-Pot Wash
Violation: There was condensate forming on the deckhead above the pot wash machine.
Recommendation: Ensure that ventilation hood systems and devices are sufficient in number and capacity to prevent grease or condensation from collecting on bulkheads and deckheads.
Item No.: 37
Site: Galley-Dishwash
Violation: There was condensate dripping from the deckhead onto the top of the dishwash machine and onto the clean landing. The machine was in active use.
Recommendation: Ensure that exhaust ventilation hood systems in food preparation and warewashing areas including components such as hoods, fans, guards, and ducting are designed to prevent grease or condensation from draining or dripping onto food, equipment, utensils, linens, and single-service and single-use articles.
Item No.: 41
Site: Housekeeping-
Violation: The exit from the public toilet rooms required the use of bare hands. This was noted in the toilet area of the spa as well as other public toilet areas.
Recommendation: Equip public toilet facilities so that persons exiting the toilet room are not required to handle the door with bare hands. This may be accomplished by methods such as locating paper towel dispensers at sinks and waste containers near the room door, installing mechanically operated doors, door removal, or other effective means.