Item No.: 33
Site: Provisions-Walk-In Refrigeration Units and Dry Stores
Violation: The deck was soiled with food debris near the bulkhead under shelves and pallets in several units. This was noted in the fruit room, soft drink room, dry stores #13, and the small dry stores room.
Recommendation: Ensure that decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, are cleaned as often as necessary.
Item No.: 27
Site: Provisions-Ice Cream Freezer
Violation: The door seal on the handle side of the door was soiled with a black material.
Recommendation: Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 18
Site: Provisions-Frozen Meat
Violation: There were two areas where whole meat was stored under raw poultry and ground beef.
Recommendation: Ensure that food is protected from cross-contamination by: (2) Separating types of raw animal foods from each other such as beef, fish, lamb, pork, and poultry during storage, preparation, holding, and display by using separate equipment for each type, or arranging each type of food in equipment so that cross-contamination of one type with another is prevented, and preparing each type of food at different times or in separate areas.
Item No.: 19
Site: Provisions-Frozen Meat
Violation: There were ice sculptures stored immediately adjacent to food products and a pan of meat stored on top of an uncarved block of ice.
Recommendation: Separate the ice sculptures from the food items stored in this unit.
Item No.: 18
Site: Provisions-Meat Thaw Room
Violation: There was raw venison stored on a trolley below ground lamb and poultry.
Recommendation: Ensure that food is protected from cross-contamination by: (2) Separating types of raw animal foods from each other such as beef, fish, lamb, pork, and poultry during storage, preparation, holding, and display by using separate equipment for each type, or arranging each type of food in equipment so that cross-contamination of one type with another is prevented, and preparing each type of food at different times or in separate areas.
Item No.: 33
Site: Preparation Room-Butcher Shop and Fish Preparation
Violation: The sealant at the deck/bulkhead juncture was peeling away from the bulkhead, leaving a difficult to clean seam. This was noted near the handwash station in the butcher shop and along the right bulkhead in the fish preparation room.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
Item No.: 38
Site: Preparation Room-Fish Preparation
Violation: The ice crusher was labeled as out of order. Staff stated that it does not work and that they have no plans for using the crusher in the future.
Recommendation: Repair or remove the ice crusher.
Item No.: 15
Site: Provisions-Shell Stock Records
Violation: There was no indication of the date of service for the mussels cooked onboard the vessel.
Recommendation: Ensure that shellstock shellfish tags: (1) Remain attached to the container in which the shellstock are received until the container is empty. (2) Are maintained by retaining shellstock tags or labels for 90 calendar days from the date the container is emptied by using an approved record keeping system that keeps the tags or labels in chronologic order correlated to the date when the shellstock are served.
Item No.: 33
Site: Galley-Pastry
Violation: The drain under the ice cream dipper well was soiled with a black material.
Recommendation: Ensure that decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, are cleaned as often as necessary.
Item No.: 12
Site: Galley-Hot Galley
Violation: There was a crew member cutting carrots with his bare hands.
Recommendation: Ensure that food employees do not contact exposed, ready-to-eat food with their bare hands and use suitable utensils such as deli tissue, spatulas, tongs, single-use gloves, or dispensing equipment.
Item No.: 26
Site: Galley-Undercounter Dish Storage
Violation: There were several tea pots that had dried leaves in the bottom and were stored as clean.
Recommendation: Ensure that food-contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 17
Site: Galley-Pastry
Violation: The potentially hazardous foods such as cheese cakes and custards were cooled in the freezer in the pastry area, but no logs were maintained for the cooling of these items.
Recommendation: Ensure that logs documenting cooked, potentially hazardous food cooling temperatures and times from the starting points designated in 7.3.5.2.1 thru the control points at 2 and 6 hours are maintained onboard the vessel for a period of 30 days form the date the food was placed in the cooling process. Ensure that logs documenting cooling of potentially hazardous foods prepared from ingredients at ambient temperatures, with the start time to the time when 5°C (41 °F) is reached are also maintained for a period of 30 days, beginning with the day of preparation.
Item No.: 30
Site: Buffet-Pool Grill
Violation: There was no 'wash hands often' sign at the handwash station at the buffet.
Recommendation: Ensure that a sign stating "WASH HANDS OFTEN" in a language that the food employees understand is posted over handwashing sinks.
Item No.: 33
Site: Pantry-Pool Grill
Violation: The trim on the door between the pantry and the buffet was cracked on both sides of the locking mechanism, making cleaning difficult.
Recommendation: Repair the damaged door trim.
Item No.: 22
Site: Pantry-Crew Bar Pantry
Violation: There was no data plate on the undercounter dishwash unit.
Recommendation: Ensure that warewashing machines are provided with an easily accessible and readable data plate affixed to the machine by the manufacturer that indicates the machine's design and operating specifications including the: (1) Temperatures required for washing, rinsing, and sanitizing; (2) Pressure required for the fresh water sanitizing rinse; and (3) Conveyor speed for conveyor machines or cycle time for stationary rack machines.
Item No.: 28
Site: Galley-Portofino Dish Wash
Violation: There was a plate of pasta stored on top of a rack of clean plates.
Recommendation: Ensure that food or other items that could contaminate clean plates or other utensils are not in the clean storage area.
Item No.: 26
Site: Galley-Portofino Dish Wash
Violation: There were two soiled coffee pots and a few soiled plates stored as clean on the racks.
Recommendation: Ensure that food-contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 20
Site: Galley-Coffee Station
Violation: The ice chute inside the ice machine was cracked, making cleaning difficult. This was corrected on site.
Recommendation: Ensure that multiuse food-contact surfaces are: (1) Smooth; (2) Free of breaks, open seams >1 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices; (4) Finished to have smooth welds and joints; and (5) Accessible for cleaning and inspection by one of the following methods without being disassembled, by disassembling without the use of tools, or by easy disassembling with the use of handheld tools commonly available to maintenance and cleaning personnel such as screwdrivers, pliers, open-end wrenches, and Allen wrenches.
Item No.: 16
Site: Galley-Coffee Station
Violation: The temperature of the milk inside the WMF machine was measured at 46°F. The milk was immediately discarded.
Recommendation: Except during preparation, cooking, or cooling, or when time is used as the public health control, ensure that potentially hazardous food is maintained: (1) At 60°C (140°F) [roasts 54°C (130°F)] or above, or (2) At 5°C (41°F) or less.
Item No.: 34
Site: Galley-Pot Wash
Violation: There was a leak under the third compartment of the three compartment sink. This was corrected on site.
Recommendation: Ensure that a plumbing system in a food area is maintained in good repair.
Item No.: 33
Site: Other-Portofino Waiter Station
Violation: The coving was missing at the center waiter station, making cleaning difficult.
Recommendation: Ensure that bulkhead and deck junctures are coved (including galleys, pantries, deck/counter junctures at buffets, bars, waiter stations, and dining room work counters).
Item No.: 08
Site: Potable Water-Bunkering Records
Violation: There were a few days where the chlorination level was at 0 ppm at the start of bunkering and the next reading was an hour later.
Recommendation: Ensure that the halogen level reaches at least 2 ppm prior to starting the hourly testing of the bunkering water.
Item No.: 08
Site: Potable Water-Bunkering and Potable Water Records
Violation: There were a few days where the production and bunkering records were not filled out correctly. The columns for bunkering and production were filled out for the same time periods and the start and end times were not recorded.
Recommendation: Ensure that the bunkering and production information is recorded properly.
Item No.: 05
Site: Potable Water-Far Point
Violation: The chart analyzer read 2.47 ppm. The inspector's manual reading was at 1.06 ppm and the staff's manual reading was at 1.15 ppm. Another test was conducted. The chart analyzer read 2.55 ppm. The inspector's manual reading was at 1.09 ppm and the staff's manual reading was at 1.17 ppm. The analyzer was calibrated two hours prior to testing.
Recommendation: Ensure that the free residual halogen measured by the halogen analyzer is ±0.2 mg/L (ppm) of the free residual halogen measured by the manual test.
Item No.: 10
Site: DO NOT USE (whirlpool/spa)-
Violation: There was no engineering approving organization stamp or flow rate on the anti-entrapment drain covers or a letter indicating that the cover meets the safety requirements.
Recommendation: Ensure that anti-entrapment drain covers or other drains that prevent entrapment hazards as specified in U.S. Consumer Product Safety Publication 363-009801 (dual drains/channel drains) are provided on swimming pools and whirlpool spas. Ensure that drain covers have either the plumbing/engineering approving organization stamp and flow rate affixed to the cover, or that a letter is maintained aboard the vessel certifying that the cover meets the safety requirements outlined in AMSE/ANSI A112.19.8M or an equivalent standard.