Item No.: 26
Site: Bar-Pool Bar
Violation: One glass was found soiled and stored as clean.
Recommendation: Ensure that food-contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 33
Site: Bar-Pool Bar
Violation: The deck had recessed grout and excess grout on the deck surface, making cleaning difficult.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
Item No.: 33
Site: Bar-Pool Bar
Violation: The deck surface below the reach-in refrigeration units had greater than 1 days accumulation of dust and debris.
Recommendation: Ensure that decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, are cleaned as often as necessary.
Item No.: 33
Site: Bar-Pool Bar
Violation: Loose power lines and conduit were on the deck, making cleaning difficult.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
Item No.: 08
Site: Potable Water-Engine Room - Laundry
Violation: The potable water lines were not striped or painted blue.
Recommendation: Stripe or paint the potable water lines blue.
Item No.: 08
Site: Potable Water-Engine Room - Laundry
Violation: There was no backflow prevention device on one of the potable water lines. A hose was attached to the line.
Recommendation: Intstall an appropriate backflow prevention device on the unprotected potable water line.
Item No.: 08
Site: Potable Water-Engine Room - Toilet
Violation: The potable water lines were not striped blue in this area.
Recommendation: Stripe or paint the potable water lines blue.
Item No.: 08
Site: Potable Water-Engine Room - Work shop
Violation: The potable water lines were not striped blue in this area.
Recommendation: Stripe or paint the potable water lines blue.
Item No.: 08
Site: Potable Water-Engine Room - Workshop
Violation: A flexible water line connection was lying in the basin of the handsink. There was no backflow protection associated with this line.
Recommendation: Install an appropriate backflow prevention device on te unprotected potable water line.
Item No.: 09
Site: DO NOT USE (whirlpool/spa)-Free Halogen Residual
Violation: For the 15 days prior to entering the US port, the bromine residual in the whirlpool regularly fell below 4.0 ppm with no indication of any action taken. When questioned, staff stated that the bromine level should be maintained between 3.0 ppm and 10 ppm. The bromine level at the time of the inspection was 5.6 ppm. The operator was educated as to the proper bromine range at the time of the inspection.
Recommendation: Ensure that whirlpool spas are maintained at a free residual chlorine of >3.0 mg/L (ppm) and <10 mg/L (ppm), or a free residual bromine of >4.0 mg/L (ppm) and <10 mg/L (ppm).
Item No.: *
Site: *General Comments-Training
Violation: It is recommended that appropriate vessel staff attend the VSP training class to ensure that they have an understanding of the 2005 VSP Operations Manual and required ranges for all vessel operations.
Recommendation:
Item No.: 33
Site: Food Service General-Food Service General - Decks
Violation: The decks were peeling or rough in the several locations, especially under equipment in the main galley, making cleaning diffcult.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
Item No.: 20
Site: Galley-Main Galley - Baker Locker
Violation: Excess sealant was noted on the interior of the door of this unit, making cleaning difficult.
Recommendation: Remove excess sealant.
Item No.: 19
Site: Galley-Main Galley - Meat Refrigerator
Violation: Water was noted dripping from the top interior of the refrigerator onto the food below. The food items were wrapped or otherwise covered.
Recommendation: Ensure that food is protected from contamination by storing the food: (1) In a clean, dry location; (2) Where it is not exposed to splash, dust, or other contamination; and (3) At least 15 centimeters (6 inches) above the deck.
Item No.: 19
Site: Galley-Main Galley - Pastry/Bakery
Violation: Condensate was noted dripping from the exterior top surface to the interior and onto the tops of covered ice cream when the lids were opened for access.
Recommendation: Ensure that food is protected from contamination by storing the food: (1) In a clean, dry location; (2) Where it is not exposed to splash, dust, or other contamination; and (3) At least 15 centimeters (6 inches) above the deck.
Item No.: 39
Site: Galley-Main Galley - Pastry/Bakery
Violation: Two live cockroaches were noted in this area.
Recommendation: Ensure that the presence of insects, rodents, and other pests is effectively controlled to minimize their presence in the food storage, preparation, service areas, warewashing, and utensil storage areas aboard a vessel.
Item No.: 33
Site: Galley-Main Galley - Dishwash Area
Violation: Broken deck tiles and rough surfaces were noted in this area.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas, are maintained in good repair.
Item No.: 26
Site: Galley-Main Galley - Dishwash Area
Violation: Two previously cleaned long plates and two saucers were found soiled and stored as clean.
Recommendation: Ensure that food-contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 26
Site: Galley-Main Galley - Ice Machine
Violation: The upper compartment of the ice machine was soiled in the ice cuber compartment with a black and light pink material. This is a repeat item from the last inspection.
Recommendation: Ensure that food-contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 20
Site: Galley-Main Galley - Ice Machine
Violation: The interior of the ice cuber compartment was corroded in some sections.
Recommendation: Ensure that materials used in the construction of multiuse utensils and food-contact surfaces of equipment are: (1) Durable, corrosion-resistant, and nonabsorbent; (2) Sufficient in weight and thickness to withstand repeated warewashing; (3) Finished to have a smooth, easily cleanable surface; and (4) Resistant to pitting, chipping, crazing, scratching, scoring, distortion, and decomposition.
Item No.: 21
Site: Galley-Main Galley - Ice Machine
Violation: The exterior of the door to the cuber compartment was damaged, leaving an opening, making cleaning difficult.
Recommendation: Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 26
Site: Galley-Main Galley - Potwash Area
Violation: Two previously cleaned hotel pans were found soiled and stored as clean.
Recommendation: Ensure that food-contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 16
Site: Galley-Main Galley - Saucier Refrigerator #7
Violation: Two packages of hot dogs were found with a product temperature of 57°F. The food was to be used for dinner. The items were placed into the blast chiller.
Recommendation: Except during preparation, cooking, or cooling, or when time is used as the public health control, ensure that potentially hazardous food is maintained: (1) At 60°C (140°F) [roasts 54°C (130°F)] or above, or (2) At 5°C (41°F) or less.
Item No.: 16
Site: Galley-Main Galley - Saucier Station
Violation: A tray of smoked bacon was found with a product temperature of 49°F. The items were placed into the blast chiller for rapid cooling.
Recommendation: Except during preparation, cooking, or cooling, or when time is used as the public health control, ensure that potentially hazardous food is maintained: (1) At 60°C (140°F) [roasts 54°C (130°F)] or above, or (2) At 5°C (41°F) or less.
Item No.: 25
Site: Galley-Food Service General - Wet Wiping Cloths
Violation: Wet wiping cloths were observed draped across sanitizer buckets in several food service locations. This is a repeat item from the previous inspection.
Recommendation: Ensure that wiping cloths used for wiping food spills are dry and used for wiping food spills from tableware and single-service articles; or wet and cleaned, stored in a chemical sanitizer, and used for wiping spills from food-contact and nonfood-contact surfaces of equipment.
Item No.: 16
Site: Galley-Main Galley - Saucier Station
Violation: Cooked vegetables were found with a product temperature of 45°F.
Recommendation: Except during preparation, cooking, or cooling, or when time is used as the public health control, ensure that potentially hazardous food is maintained: (1) At 60°C (140°F) [roasts 54°C (130°F)] or above, or (2) At 5°C (41°F) or less.
Item No.: 29
Site: Galley-Main Galley - Saucier Station
Violation: The handwash station was partially blocked by a large trash can. This item was corrected during the inspection.
Recommendation: Ensure that handwashing facilities are used for no other purpose and are accessible at all times.
Item No.: 16
Site: Galley-Main Galley - Two-Stage Cooling for Cooked Potentially Hazardous Foods
Violation: There is no record of the two-stage cooling process indicating the ship is cooling cooked potentially hazardous foods (PHFs) from 140°F to 70°F in 2 hours, followed by cooling to 41°F or below in an additional 4 hours. The ship's blast chiller logs simply recorded the time and temperature when the product was placed inside the blast chiller and the time and temperature when it was removed from the blast chiller.
Recommendation: Ensure that cooked potentially hazardous food is cooled: (1) Within 2 hours, from 60°C (140°F) to 21°C (70°F); and (2) Within 4 hours, from 21°C (70°F) to 5°C (41°F) or less.
Item No.: 08
Site: Galley-Topside Pantry
Violation: The spray nozzle for rinsing dishes, hung below the flood rim of the single-compartment sink. There was a continuous pressure backflow prevention device on the hot water supply line only.
Recommendation: Install a continuous pressure backflow prevention device on the spray hose.
Item No.: 11
Site: Medical-Medical - Written Personal Hygiene Information Sheet
Violation: A written personal hygiene information and handwashing tip sheet was not provided to passengers with acute gastroenteritis.
Recommendation: Ensure that symptomatic passengers meeting the defintion for AGE are provided handwashing tips and personal hygiene information.
Item No.: 02
Site: Medical-Medical - GI Logs
Violation: The current GI log document does not include the following symptoms: abdominal cramps, myalgia/muscle aches, headache. These symptoms were added to the GI log requirements in the 2005 VSP Operations Manual.
Recommendation: The gastrointestinal illness surveillance log entry for each passenger or crew member shall contain the following information: (1) The first date of clinic visit or report to staff of illness; (2) The person's name, age and gender; (3) A designation as passenger or crew member; (4) Crew member position or job on the vessel, if applicable; (5) Cabin number; (6) Meal seating information; (7) Date and time of illness onset; (8) Illness symptoms, including the presence of the following selected signs and symptoms: numbers of episodes each of diarrhea and vomiting per day, bloody stools, fever, recorded temperature, abdominal cramps, headaches and muscle aches; (9) Notation on whether or not a stool specimen was requested and received; (10) Use of antidiarrheal medication; and (11) The presence of underlying medical conditions which may affect interpretation of acute gastrointestinal illness for example diabetic diarrhea, inflammatory bowel disease, gastrectomy or others.
Item No.: 02
Site: Medical-Medical - Insulated Shippers
Violation: The vessel has shipping containers that meet the IATA/DOT shipping requirements. However, the shipping containers are not the type required for shipping items that require refrigeration (e.g., they are not insulated), as is the requirement when shipping clinical specimens for either viral or bacterial analysis.
Recommendation: Obtain shipping containers the allow for the shipment of refrigerated clinical specimens.