Item No.:
27
|
|
Site:
Galley-Deck 8 Cafe Bordeaux
|
|
Violation:
The technical space of the salamander was soiled with greater than one days accumulation of food debris.
|
|
Recommendation:
Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
16
|
|
Site:
Galley-Deck 8 Cafe Bordeaux
|
|
Violation:
The milk inside of the MWF coffee machine was measured at 48°F. Staff stated that this milk was placed in the unit one hour prior to the inspection and was on temperature control. The milk was discarded.
|
|
Recommendation:
Except during preparation, cooking, or cooling, or when time is used as the public health control, ensure that potentially hazardous food is maintained: (1) At 60°C (140°F) [roasts 54°C (130°F)] or above, or (2) At 5°C (41°F) or less.
|
|
|
Item No.:
24
|
|
Site:
Galley-Deck 6 Pot Wash
|
|
Violation:
The sanitizing solution for the three bucket system was measured at greater than 200 ppm. This was corrected during the inspection.
|
|
Recommendation:
Ensure that a chlorine solution used as a sanitizing solution has a concentration between 50 mg/L (ppm) and 200 mg/L (ppm).
|
|
|
Item No.:
19
|
|
Site:
Buffet-Deck 5
|
|
Violation:
Side shields were not provided on the crew buffet or the officers mess buffet sneeze guards.
|
|
Recommendation:
Install side shields on the sneeze guards of the crew and officer mess buffet lines on the ends where personnel line up for the buffet.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Deck 5 Officers Pantry
|
|
Violation:
The backflow device on the table mounted ice machine was leaking onto the counter. This area was not in use and a new device was installed during the inspection.
|
|
Recommendation:
Replace the leaking backflow device.
|
|
|
Item No.:
33
|
|
Site:
Provisions-Deck 4 Dairy Walk-in Refrigerator
|
|
Violation:
A large gap was noted between the deck and the bulkhead on the left side of the unit, making cleaning difficult.
|
|
Recommendation:
Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas, are maintained in good repair.
|
|
|
Item No.:
33
|
|
Site:
Food Service General-Waiter Stations
|
|
Violation:
The deck/waiter station junctures were not coved in several food service areas, making cleaning difficult. This was noted on the previous inspection on September 2006.
|
|
Recommendation:
Ensure that bulkhead and deck junctures are coved (including galleys, pantries, deck/counter junctures at buffets, bars, waiter stations, and dining room work counters).
|
|
|
Item No.:
21
|
|
Site:
Bar-Anderson's Bar
|
|
Violation:
There was a hole in the lower right corner of the technical compartment to the right of the second speed rail.
|
|
Recommendation:
Repair the hole in the technical compartment. Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|