Cruise Ship: Coral Princess Cruise Line: Princess Cruises Inspection Date: 05/24/2007 Inspection Score: 100
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 22
Site: Galley-Deck 5 Pot Wash
Violation: The pot wash machine data plate recommended a final sanitizing time of 25 seconds. The actual sanitizing time was monitored at 17 seconds. Engineering staff was called to lengthen the sanitizing cycle.
Recommendation: Ensure that warewashing machines and their auxiliary components: (1) Are operated in accordance with the machine's data plate and other manufacturer's instructions. (2) A warewashing machine's conveyor speed or automatic cycle times are maintained accurately timed in accordance with manufacturer's specifications.
Item No.: 21
Site: Galley-Bell Box Starboard Side
Violation: Peeling sealant was noted on the plate warmer heating element.
Recommendation: Remove the peeling sealant.
Item No.: 24
Site: Bar-Pool Bar
Violation: The sanitizing solution was measured at over 200 ppm. This was corrected during the inspection.
Recommendation: Ensure that a chlorine solution used as a sanitizing solution has a concentration between 50 mg/L (ppm) and 200 mg/L (ppm).
Item No.: 33
Site: Galley-Pizzeria
Violation: The bottom of the bulkhead was damaged, exposing wood and plaster. This was noted in the entrance corridor. Staff stated that a work order was in place to repair this bulkhead.
Recommendation: Repair or replace the bulkhead with a smooth, durable and easily cleanable surface. Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas, are maintained in good repair.
Item No.: 28
Site: Galley-Horizon Court
Violation: Tile work was being performed next to the clean glass storage. Staff rewashed the glasses and placed the storage rack out of service.
Recommendation: Ensure that cleaned equipment and utensils, laundered linens, and single-service and single-use articles are stored: (1) In a clean, dry location; (2) Where they are not exposed to splash, dust, or other contamination; and (3) At least 150 mm (6 inches) above the deck.
Item No.: 29
Site: Galley-Dishwash
Violation: The handwash station at the soiled landing was blocked by dishware. This area was in active use and the items were moved during the inspection.
Recommendation: Ensure that handwashing facilities are used for no other purpose and are accessible at all times.
*Inspections scores of 85 or lower are NOT satisfactory