Cruise Ship: Adventure of the Seas Cruise Line: Royal Caribbean International Inspection Date: 06/24/2007 Inspection Score: 100
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 08
Site: Galley-Combi-oven #1005
Violation: The backflow prevention device was continuously leaking.
Recommendation: Ensure that backflow preventers are maintained in good repair.
Item No.: 08
Site: Pantry-Schooner Bar
Violation: The backflow prevention device on the coffee machine was a non-continuous pressure type unit.
Recommendation: Ensure that a continuous pressure-type backflow preventer is installed when a valve is located downstream from the backflow preventer.
Item No.: 08
Site: Potable Water-
Violation: The list of backflow prevention devices for Facilities indicated that the devices on the washing machines in the crew launderettes were non-continuous pressure. The device appeared to be a continuous pressure device. The same device was installed on the hose at the sink in the photo shop. This hose had a sprayer attached to the end of the hose. For both of these applications, a continuous pressure type backflow prevention device is required due to the downstream valve.
Recommendation: Investigate the type of backflow prevention device that is installed on the washing machines in the crew launderettes and on the hose in the photo shop. Ensure that it is a continuous pressure device and update the list of backflow prevention devices.
Item No.: 08
Site: Potable Water-Cross-connection Control Records
Violation: The list of non-testable backflow prevention devices for the Engineering Department indicated "Type B9" for each of the locations. The installed devices appeared to be Watts N9.
Recommendation: Ensure that the correct devices are in the list of backflow prevention devices.
Item No.: 20
Site: Other-Officer's Mess - Buffet Line
Violation: Reach-in refrigerator #1015 was posted out of order for the past 1 week. This is the only refrigeration unit in the area.
Recommendation: Repair or replace the unit to ensure proper cold holding capacity in this area.
Item No.: 21
Site: Galley-Deck 5
Violation: Crisp bacon was placed in the far right, upper alto-sham unit for hot holding two hours prior to the inspection. The unit's exterior mounted ambient air thermometer indicated an internal temperature of 187°F. A second, internal, ambient air thermometer registered 140°F. The temperature of the crisp bacon was measure at 95°F. The crisp bacon is not a potentially hazardous food.
Recommendation: Ensure that ambient air temperature measuring devices are maintained in good repair and are accurate within the intended range of use.
Item No.: 21
Site: Galley-Hot Galley
Violation: Peeling labels were noted on flat-top grill #1009, making cleaning difficult.
Recommendation: Remove the peeling labels.
Item No.: 21
Site: Bar-Sky Bar
Violation: In the technical compartment under the speed rail near the handwash station, the old multi-flow lines were cut, leaving multiple opening that were difficult to clean.
Recommendation: Remove the un-unused multi-flow lines and seal the back of the technical compartment once the hoses are removed.
Item No.: 21
Site: Buffet-Lido-Starboard Side Forward
Violation: Utility lines were installed on the floor of the technical space, obstructing cleaning.
Recommendation: Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 21
Site: Buffet-Lido-Starboard Side Forward
Violation: The utility line clamps. located in the technical space, were galvanized metal and heavily corroded. This is the result of utilizing dissimilar metals.
Recommendation: Ensure that nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material.
Item No.: 21
Site: Buffet-Island Grill Starboard Aft
Violation: The sneeze guard over-shelf had excessive sealant, making the surface difficult to clean.
Recommendation: Remove sealant to allow proper cleaning.
Item No.: 21
Site: Buffet-Island Grill Aft
Violation: There is a void space behind and below the undercounter Alto-Sham units, creating a space that cannot be cleaned and allows for possible pest harborage.
Recommendation: Ensure that equipment that is fixed because it is not easily movable is installed so that it is: (1) Spaced to allow access for cleaning along the sides, behind, under and above the equipment; (2) Spaced from adjoining equipment, bulkhead, and deckhead at a distance of not more than 0.8 millimeter or 1/32 inch; or (3) Sealed to adjoining equipment or bulkhead, if the equipment is exposed to spillage or seepage.
Item No.: 22
Site: Galley-Potwash
Violation: During operation, water was spraying from the potwash machine door frame and accumulating on the deck.
Recommendation: Repair/install door seals to prevent discharge from the unit.
Item No.: 28
Site: Bar-Pool Bar
Violation: There were recently washed new souvenir soda containers in the clean storage rack. The containers were inverted, but the lids had been attached, impeding air drying.
Recommendation: After cleaning and sanitizing, ensure that equipment and utensils are air-dried or adequately drained before contact with food.
Item No.: 33
Site: Provisions-Dairy Walk-in Refrigerator #1878
Violation: The top of the starboard door was damaged, making cleaning difficult. The bottom, interior portside door molding was separating, leaving openings, making cleaning difficult.
Recommendation: Repair the door and secure or replace the molding as needed.
Item No.: 33
Site: Buffet-Lido-Port Side Forward
Violation: The vertical edge of the counter was separated at the deck juncture, creating a gap.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas, are maintained in good repair.
Item No.: 34
Site: Galley-Ice Machine #11-4
Violation: The water level tubing between the water bath trays was torn, allowing potable water to flow into the ice bin below. The ice bin was empty.
Recommendation: Replace the tubing.
Item No.: 40
Site: Integrated Pest Management-Inspection Logs
Violation: According to the pest management logs, the passive and active night time inspections were conducted as early as 3:30 pm.
Recommendation: Ensure that night time inspections are conducted during night time hours.