Cruise Ship: Asuka II Cruise Line: NYK Cruises Co., LTD Inspection Date: 06/03/2007 Inspection Score: 88
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 02
Site: Medical-Medical - GI Log Maintenance
Violation: The GISS log maintained for the voyage ending 06/02/2007, listed 4 cases that met the case definition. However, the column for reported had "N" entered for each case-patient.
Recommendation: Ensure reported cases of AGE are recorded correctly as cases in the GISS log.
Item No.: 02
Site: Medical-Medical - Shipping Containers and Labels
Violation: Shipping labels for the shipping of clinical specimens were not available.
Recommendation: Obtain proper shipping labels for clinical specimens.
Item No.: 27
Site: Other-Officer's Mess
Violation: The technical compartment shelf of the salad bar was soiled with greater than one day's accumulation of dirt and debris.
Recommendation: Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 19
Site: Other-Officer's Mess
Violation: The dispensing utensils at the bread containers were uncovered or otherwise protected from contamination.
Recommendation: Ensure that each self-service food dispensing utensil is covered or located beneath shielding during service.
Item No.: 21
Site: Pantry-Officer's Pantry
Violation: Two small holes were noted in the countertop under the coffee machine, making cleaning difficult.
Recommendation: Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 33
Site: Pantry-Officer's Pantry
Violation: No coving was noted observed at the deck-bulkhead juncture in this area.
Recommendation: Ensure that bulkhead and deck junctures are coved (including galleys, pantries, deck/counter junctures at buffets, bars, waiter stations, and dining room work counters).
Item No.: 33
Site: Pantry-Officer's Pantry
Violation: Holes, openings around pipe penetrations and other difficult to clean features were observed in the deckhead in this area.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
Item No.: 21
Site: Pantry-Officer's Pantry
Violation: Open channels were noted at the tops of the legs of the tea preparation table where food and debris could collect, making cleaning difficult.
Recommendation: Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 27
Site: Galley-Crew Galley - Fryer Section
Violation: Excess grease build-up was noted in the technical compartment of the previously cleaned deep fat fryers identified as DFF #1 and DFF #2.
Recommendation: Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 08
Site: Galley-Crew Galley - Fryer Section
Violation: A backflow prevention device could not be located on the potable water lines to two small combination ovens.
Recommendation: Ensure an appropriate backflow prevention device (continuous pressure) is installed at this location
Item No.: 21
Site: Galley-Crew Galley
Violation: The flat-top cooker surfaces had gaps, seams slotted fasteners and other difficult to clean features.
Recommendation: Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 21
Site: Galley-Crew Galley
Violation: The control panel to the flat-top cooker surfaces was missing a large screw component, leaving an opening where food and debris could collect, making cleaning difficult.
Recommendation: Replace missing screw/bolt.
Item No.: 21
Site: Galley-Crew Galley - Refrigeration Section
Violation: The handle to the undercounter blast chiller was missing an end cap, leaving an opening where food and debris could collect, making cleaning difficult.
Recommendation: Replace missing end cap to the handle of the undercounter blast chiller.
Item No.: 33
Site: Galley-Crew Galley - Potwash Area
Violation: The deck beneath the mechanical potwash was deteriorated, leaving rough surfaces, making cleaning difficult.
Recommendation: Ensure that bulkheads and deckheads have smooth, hard finishes, and light colored surfaces.
Item No.: 33
Site: Galley-Crew Galley - Potwash Area
Violation: The coving beside and behind the mechanical potwash was missing.
Recommendation: Replace missing coving.
Item No.: 22
Site: Galley-Crew Galley - Potwash Area
Violation: The mounted final rinse temperature gauge measured in excess of 220 °F. The measured final rinse temperature was 174.8 °F at the pot surface. It appears the gauge is defective or out of calibration. The machine was in active use at the time of the inspection. The mounted final rinse pressure gauge measured greater than 30 psi.
Recommendation: Repair or replace defective final rinse temperature gauge.
Item No.: 21
Site: Galley-Crew Galley - Potwash Area
Violation: A whisk was found with a wire wrapped handle that was difficult to clean. This item was discarded during the inspection.
Recommendation: Ensure utensils are easily cleanable.
Item No.: 33
Site: Other-Crew Mess
Violation: The bulkhead panels behind the beverage station were separating, leaving openings, making cleaning difficult. The coving at the base of the beverage station was separating from the bulkhead, making cleaning difficult.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas, are maintained in good repair.
Item No.: 21
Site: Other-Crew Mess
Violation: The laminate countertop of the storage cabinet was deteriorated along the edges, making cleaning difficult.
Recommendation: Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 33
Site: Other-Crew Mess
Violation: Holes (bulkhead), openings around pipe penetrations (deckhead) and separating bulkhead panels were noted in the buffet area, making cleaning difficult.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
Item No.: 33
Site: Provisions-Provisions - Wine Walk-in #401
Violation: Three holes were noted in the bulkhead on the interior near the threshold of this unit.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas, are maintained in good repair.
Item No.: 33
Site: Provisions-Provisions - Vegetable Walk-in (rear unit)
Violation: Two loose profile strips were noted at the deck-bulkhead juncture near the door.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas, are maintained in good repair.
Item No.: 36
Site: Provisions-Provisions - Meat Freezer
Violation: A light attached to the deckhead was not working.
Recommendation: Ensure that the light intensity is at least 220 Lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment, and utensil storage, pantries, toilet rooms, and consumer self-service areas.
Item No.: 36
Site: Provisions-Provisions - Dry Storage
Violation: The lighting over the olive storage area was less than 110 lux.
Recommendation: Ensure that the light intensity is at least 110 Lux (10 foot candles) at a distance of 75 centimeters (30 inches) above the deck when in use, in walk-in refrigerator units and dry storage areas, and in other areas and rooms during periods of cleaning.
Item No.: 33
Site: Other-Four Seasons Dining Room
Violation: The vinyl deck material at the center wait station near the main entrance, was missing a section, making cleaning difficult.
Recommendation: Replace missing section of vinyl deck material.
Item No.: 29
Site: Galley-Main Galley - Dishwash Area (STBD)
Violation: There was no hot water at the handwash station outside the dishwash area. The hot water valve was turned off. This item was corrected during the inspection.
Recommendation: Ensure that handwashing sinks are equipped to provide water at a temperature of at least 43°C (110°F) through a mixing valve or combination faucet. For handwash sinks with electronic sensors, where the user cannot make temperature adjustments, ensure that the temperature provided to the user does not exceed 52°C (125°F).
Item No.: 37
Site: Galley-Main Galley - Dishwash Area (STBD)
Violation: Condensate was observed on the bulkheads and deckheads at the clean side of the dishwash and glasswash operations.
Recommendation: Ensure that exhaust ventilation hood systems in food preparation and warewashing areas including components such as hoods, fans, guards, and ducting are designed to prevent grease or condensation from draining or dripping onto food, equipment, utensils, linens, and single-service and single-use articles.
Item No.: 26
Site: Galley-Main Galley - Ice Station
Violation: The interior of the previously cleaned soft serve ice cream machine was soiled. The machine had been reassembled and was ready for use. The machine was used two days prior.
Recommendation: Ensure that food only contacts surfaces of equipment and utensils that are cleaned and sanitized.
Item No.: 33
Site: Galley-Main Galley - Ice Station
Violation: Water was observed pooled on the deck behind the ice machines.
Recommendation: Ensure that decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, are cleaned as often as necessary.
Item No.: 13
Site: Galley-Main Galley -Coffee Station
Violation: A galley employee tested the sanitizer bucket halogen concentration using pH test strips.
Recommendation: Person in charge: Ensure that employees are properly sanitizing cleaned multiuse equipment and utensils before they are reused, through routine monitoring of solution temperature and exposure time for hot water sanitizing, and chemical concentration, pH, temperature, and exposure time for chemical sanitizing.
Item No.: 21
Site: Galley-Main Galley -Coffee Station
Violation: Several large waiter trays were noted damaged along the edges, making cleaning difficult.
Recommendation: Replace damaged waiter trays.
Item No.: 33
Site: Galley-Main Galley -Pastry
Violation: Two profiles strips at the end of the large preparation counter were separating from the bulkhead adjacent to the walk-in refrigerators, leaving openings, making cleaning difficult.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas, are maintained in good repair.
Item No.: 38
Site: Galley-Main Galley -Pastry
Violation: The soft serve ice cream machine was poasted out of order for an undetermined, but lengthy, period of time. According to ship's staff, this items is scheduled to be removed from the vessel.
Recommendation: Ensure that only articles necessary for the food service operation are stored in food preparation, food storage, and warewashing areas.
Item No.: 27
Site: Galley-Main Galley -Pastry
Violation: The gears of the small dough sheeter were heavily soiled with old food debris.
Recommendation: Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 26
Site: Galley-Main Galley -Pastry
Violation: The cloth belt of the previously cleaned dough sheeter had a moderate amount of flour residue. The equipment was last used two days prior to the inspection.
Recommendation: Ensure that food-contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 21
Site: Galley-Main Galley - Soup Station
Violation: Small holes were noted in the top portion of the flat-top cooking surface.
Recommendation: Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 33
Site: Galley-Main Galley - Beverage Station
Violation: Some bare areas where deck tiles were missing were noted under the beverage dispensing equipment. The deck tiles under the equipment did not extend to the base of the bulkhead, leaving areas where food and debris could collect, making cleaning difficult.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas, are maintained in good repair.
Item No.: 21
Site: Galley-Main Galley - Hot Galley
Violation: Peeling labels were noted on the non-food-contact surfaces of the deep fat fryers, making cleaning difficult.
Recommendation: Remove peeling labels from equipment.
Item No.: 33
Site: Galley-Main Galley - Hot Galley
Violation: Recessed grout was noted in this area.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas, are maintained in good repair.
Item No.: 21
Site: Galley-Main Galley - Hot Galley
Violation: A tilting pan was posted out of order. The ship is awaiting spare parts.
Recommendation: Repair tilting pan.
Item No.: 33
Site: Galley-Main Galley - Hot Galley
Violation: Cracked and broken tile coving was noted near the combination ovens.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas, are maintained in good repair.
Item No.: 21
Site: Galley-Main Galley - Hot Galley
Violation: The floor-model mixer was posted out of order. The ship is awaiting spare parts.
Recommendation: Repair floor-model mixer.
Item No.: 21
Site: Galley-Main Galley - Hot Galley
Violation: The cast iron cooking surfaces had gaps, seams, hex fasteners and other difficult to clean features.
Recommendation: Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 33
Site: Galley-Main Galley - Hot Galley
Violation: Water was noted pooled on the deck behind the combination ovens.
Recommendation: Ensure that decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, are cleaned as often as necessary.
Item No.: 33
Site: Galley-Main Galley - Cold Galley
Violation: Rough deck surfaces were noted under and behind the ice machine.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
Item No.: 33
Site: Galley-Main Galley - Transport Corridor (between port and starboard main galleys)
Violation: The vinyl deck material is deteriorated, making cleaning difficult.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
Item No.: 08
Site: Galley-Main Galley
Violation: Several deck taps with threaded hose bibbs were noted without any backflow prevention devices. There were no hoses attached at the time of the inspection.
Recommendation: Ensure appropriate backflow prevention devices at these locations.
Item No.: 40
Site: Integrated Pest Management-Integrated Pest Management Program (IPM)
Violation: The IPM program documentation did not provide guidance in the recognition and identification of common pests.
Recommendation: Ensure that the Integrated Pest Management Plan includes provisions for active monitoring including pest sighting logs for the operational areas of the vessel and training for crew members in charge of log completion.
Item No.: *
Site: *General Comments-Outbreak Prevention and Response Plan (OPRP)
Violation: A review of the OPRP indicated the following: 1. references were made to the use of chlorine for norovirus control with concentration of 500-2000 ppm 2. references were made to using chlorine disinfection on food-contact surfaces with concentrations of 500-2000 ppm without any mention of final rinse steps 3. references were made to the removal of vomit incidents with a wet/dry vacuum without a disinfection step and appropriate contact times.
Recommendation: Recommend sending the OPRP to the VSP office (attn: CAPT George Vaughan) for a more detailed review with subsequent recommendations for improvement.
Item No.: 22
Site: Food Service General-Deck Pantries - Ice and Food
Violation: The Electrolux undercounter, single rack dishwash machines in all the pantries had manufacturer's data plates which did not list the machine's cycle times for wash or final rinse. This includes the new pantries forward and aft on deck 10.
Recommendation: Ensure that warewashing machines are provided with an easily accessible and readable data plate affixed to the machine by the manufacturer that indicates the machine's design and operating specifications including the: (1) Temperatures required for washing, rinsing, and sanitizing; (2) Pressure required for the fresh water sanitizing rinse; and (3) Conveyor speed for conveyor machines or cycle time for stationary rack machines.
Item No.: 08
Site: Potable Water-Backflow Preventers - Located near the decks
Violation: The backflow prevention devices mounted near to the deck in the aft deck 10 pantry, most of the other deck pantries, and in the Piano Bar Pantry had small diameter drain pipes screwed onto the backflow preventer's atmospheric vent. These vent drain pipes were extended from the deck level beneath equipment like ice machines, dishwash machines, and coffee machines to a deck drain about one meter away. The problem was that the deck drains had a raised rim surrounding them which forced the end of the drain pipe to be elevated above the deck so as to defeat the principle of gravity, and forcing wastewater back to the backflow preventer.
Recommendation: Elevate the backflow preventer vent drain pipe to provide gravity flow to the deck drains adjacent or remove the vent pipe altogether and allow the preventer vent to drain to the open deck.
Item No.: 06
Site: Potable Water-Distribution System - Far Point Alarm
Violation: Staff could not verify that there was an audible alarm in the bridge which sounded when there was a low free chlorine residual at the far point in the potable water distribution system. There were analyzer recorder charts which clearly showed free chlorine residual readings below the 0.2 ppm which lasted for 4 hours or more, so an alarm should have sounded and staff would then respond to the alarm.
Recommendation: Ensure that at least one backup halogen pump is available with automatic switchover to maintain the free residual halogen in the event that the primary pump fails, an increase in demand occurs, or the low chlorine alarm sounds.
Item No.: 09
Site: Recreational Water Facilities-Seahorse Pool
Violation: The swimming pool was open for use and the free chlorine residual measured with the inspector's kit was 0.24, 0.34, and 0.94 in three separate positions of the pool. Engineering staff stated that the reading in the pump room at the time was 3.3 ppm, and a manual test made at the pool was 1.1 ppm free chlorine. The test kit used by the engineer's was set to a high range and they were using a plastic sample cell. Instructions for this kit specify using the low test range for chlorine when the free residual is below 2 ppm, and that the glass sample cell should be used for this reading. When this was explained, the staff were not familiar enough with their test kit to switch the test range over to the low range.
Recommendation: Ensure that a free residual halogen of >1.0 and <5.0 mg/L (ppm) is maintained in recirculated swimming pools.
Item No.: 09
Site: DO NOT USE (whirlpool/spa)-Forward and Aft Whirlpool Spas
Violation: The free chlorine residual of the open aft whirlpool spa was 0.13 ppm. The free chlorine residual of the open forward whirlpool spa was only 0.81 ppm by the inspector's manual test kit. The ship used a color comparison kit for the test and reported 1.5 ppm. When the inspector viewed the test color it was unclear to read, due to small dots on the comparison colors at 1 ppm and below, but the value appeared to be between 0.8 and 1 ppm. Staff stated that the a manual test made early this morning was over 5 ppm.
Recommendation: Ensure that whirlpool spas are maintained at a free residual chlorine of >3.0 mg/L (ppm) and <10 mg/L (ppm), or a free residual bromine of >4.0 mg/L (ppm) and <10 mg/L (ppm).
Item No.: 09
Site: Recreational Water Facilities-Pools and Whirlpool Spa
Violation: In reviewing the pool, whirlpool spa, and grand bath records, there were consistent values of over 2 ppm for the pool and the whirlpool spa over 3 ppm, based both on analyzer strip chart readings and manual comparison tests, but staff admitted that the manual tests were not made in the actual pool, whirlpool spas, or bath water, but were made in the pump rooms for these facilities at the test cock for the controlling analyzer. Staff on todays measures in the pool and whirlpool spa were of the view that the pool and whirlpool spa values would automatically rise, even though there were clear measures from the pump room above 3 ppm while the pool or spa tub reading near the same time was less than 1 ppm. Staff were told to immediately close the pool and both whirlpool spas afte these initial tests at noon. At 2 pm the two whirlpool spas were closed with access blocked, but there was no net on the Seahorse Pool. The inspector made a manual test of the pool at that time and the free chlorine residual was 0.82 ppm. Engineers were again instructed to close the pool and net it to prevent passenger use until a proper residual was maintained throughout of at least 1 ppm.
Recommendation: Ensure that a free residual halogen of >1.0 and <5.0 mg/L (ppm) is maintained in recirculated swimming pools. Ensure that whirlpool spas are maintained at a free residual chlorine of >3.0 mg/L (ppm) and <10 mg/L (ppm), or a free residual bromine of >4.0 mg/L (ppm) and <10 mg/L (ppm).
Item No.: 10
Site: Recreational Water Facilities-Seahorse Pool and Grand Bath
Violation: The single drain cover for the Seahorse pool does not appear to have an anti-entrapment design and there was no written certification that this was an anti-entrapment drain cover. The grand bath still water baths had drain covers which were not anti-entrapment in design and there was not a written certification that these were anti-entrapment drain covers. This violation was also noted in the inspection of June 2006. Staff stated that the matter was referred to the cruise line office for a response, but nothing has been received onboard to date.
Recommendation: Ensure that anti-entrapment drain covers or other drains that prevent entrapment hazards as specified in U.S. Consumer Product Safety Publication 363-009801 (dual drains/channel drains) are provided on swimming pools and whirlpool spas. Ensure that drain covers have either the plumbing/engineering approving organization stamp and flow rate affixed to the cover, or that a letter is maintained aboard the vessel certifying that the cover meets the safety requirements outlined in AMSE/ANSI A112.19.8M or an equivalent standard.
Item No.: 08
Site: Potable Water-Cross-Connection Control Program
Violation: There was no visual inspection record made for the various backflow preventers which cannot be tested and are located throughout the ship.
Recommendation: Ensure a visual inspection is coducted periuodically on all non-testable backflow prevention devices.
Item No.: 36
Site: Galley-Lido - Ice Pantry
Violation: There was less than 220 lux along the top and back section of the two ice machines in the ice pantry.
Recommendation: Ensure that the light intensity is at least 220 Lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment, and utensil storage, pantries, toilet rooms, and consumer self-service areas.
Item No.: 33
Site: Galley-Lido - Ice Pantry
Violation: The bulkhead behind the two ice machines in the ice pantry were soiled with dust debris and had corrosion and liquid stains.
Recommendation: Ensure that decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, are cleaned as often as necessary.
Item No.: 33
Site: Other-Prego - Waiter Station
Violation: The deck juncture with the counter foundation for the waiter station as well as the half height bulkhead opposite was not coved, making cleaning difficult.
Recommendation: Ensure that bulkhead and deck junctures are coved (including galleys, pantries, deck/counter junctures at buffets, bars, waiter stations, and dining room work counters).
Item No.: 21
Site: Galley-Lido - Hot Galley
Violation: There was an open seam along the underside exterior panel of the tilting braising pan, where the bottom panel was separating from the pan bottom.
Recommendation: Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 27
Site: Galley-Lido - Hot Galley
Violation: There was food and grease residue lodged in the open seam of the exterior underside of the tilting braising pan.
Recommendation: Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 22
Site: Other-Lido Grill - Dishwash
Violation: The conveyor dishwash machine did not display or have a manufacturer's data plate with the machine's conveyor speed identified.
Recommendation: Ensure that warewashing machines are provided with an easily accessible and readable data plate affixed to the machine by the manufacturer that indicates the machine's design and operating specifications including the: (1) Temperatures required for washing, rinsing, and sanitizing; (2) Pressure required for the fresh water sanitizing rinse; and (3) Conveyor speed for conveyor machines or cycle time for stationary rack machines.
Item No.: 29
Site: Bar-Piano Bar
Violation: The front bar has only a single, deep sink installed with handwashing sign, soap dispenser and paper towel dispenser. Staff stated that they wash out drink-making glasses, spoons, and shakers in the sink in the pantry, but the shaker cup and spoon were setting on the front bar counter within 1 meter of the handwash sink.
Recommendation: Recommend the pantry door be converted to a swinging door to allow access to the handwash station behind and return of the bar sink to a proper utility sink.
Item No.: 16
Site: Other-Sushi Garden
Violation: Two aquariums were installed, filled with water, and operating during the inspection. One aquarium was empty, but the second had 4 live fish (3 types) swimming inside, none of which were tuna. Staff stated there were more yesterday, and that these fish were procured in New York after arrival in port. Staff also stated these fish are processed into both sushi and sashimi upon passenger selection and request, then served in a raw state.
Recommendation: Before service in ready-to-eat form, ensure that raw, raw-marinated, partially cooked, or marinated-partially cooked fish other than molluscan shellfish: (1) Are frozen throughout to a temperature of -20°C (-4°F) or below for 168 hours (7 days) in a freezer; or -35°C (-31°F) or below for 15 hours in a blast freezer. Obtain certification from the vendor that the fish are parasite free.
*Inspections scores of 85 or lower are NOT satisfactory