Cruise Ship: Seven Seas Mariner Cruise Line: Regent Seven Seas Inspection Date: 07/15/2007 Inspection Score: 100
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 37
Site: Galley-Starboard Dishwash
Violation: Condensate was forming on the bulkhead and deckhead at the clean end of the machine. Excessive steam was coming from the clean end chute. The plate surface temperature was measured at 178°F indicating that the manifold temperature may be in excess of 194°F.
Recommendation: Lower the final rinse temperature to reduce the amount of stream discharged from the dishwash machine. The plate surface temperature only needs to be a minimum of 160°F.
Item No.: *
Site: Food Service General-Main and Crew Galleys
Violation: The drinking fountains had cup filling spigots. Staff indicated that the spigots are utilized to fill drinking glasses for galley crew. No crew members were observed drinking in the galleys.
Recommendation: Remove the cup filing spigots. Ensure that employees eat, drink, or use any form of tobacco only in designated areas where the contamination of exposed food; clean equipment, utensils, and linens; unwrapped single-service and single-use articles; or other items needing protection can not result.
Item No.: 20
Site: Galley-Fish Section
Violation: A small hole was noted in the prep table surface were previously installed equipment had been removed.
Recommendation: Ensure that multiuse food-contact surfaces are: (1) Smooth; (2) Free of breaks, open seams >1 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices; (4) Finished to have smooth welds and joints; and (5) Accessible for cleaning and inspection by one of the following methods without being disassembled, by disassembling without the use of tools, or by easy disassembling with the use of handheld tools commonly available to maintenance and cleaning personnel such as screwdrivers, pliers, open-end wrenches, and Allen wrenches.
Item No.: 21
Site: Galley-Pot Wash - Clean Storage Rack
Violation: The rubber coating on a few service trays was peeling, making cleaning difficult. Staff indicated that the trays are checked and discarded every three months.
Recommendation: Ensure that nonfood-contact surfaces of equipment and utensils are designed and constructed to be durable and to retain their characteristic qualities under normal use conditions.
Item No.: 24
Site: Galley-Potwash
Violation: Staff were not consistently removing items from the chemical sanitizing rinse sink before the full 7 seconds contact time. When queried, the proper response was given.
Recommendation: Ensure that the chemical sanitizer is used in accordance with the EPA-approved manufacturer's label use instructions at a minimum temperature of 24°C (75°F) with an exposure time of 7 seconds for a chlorine solution and 30 seconds for other chemical sanitizers.
Item No.: 20
Site: Galley-La Veranda
Violation: The "Scotsman" ice machine had slotted fasteners in the water bath reservoir.
Recommendation: Replace the slotted fasteners with low profile, smooth, non-corroding fasteners.
Item No.: 21
Site: Buffet-La Veranda-Juice Fruit Service Bar
Violation: Portions of the storage space access door laminate material was chipped, creating a rough surface.
Recommendation: Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 33
Site: Bar-Pool Bar
Violation: The deck of technical space #226 was soiled.
Recommendation: Ensure that decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, are cleaned as often as necessary.
Item No.: 33
Site: Bar-Observation Bar
Violation: A few light fixtures above the bar were not secured to the ceiling creating gaps.
Recommendation: Secure light fixtures to the deckhead. Ensure that light fixtures, vent covers, and similar equipment attached to the bulkheads or deckheads are easily cleanable.
Item No.: 33
Site: Galley-Signature
Violation: There were holes in the pass thru door frame creating void spaces and making cleaning difficult.
Recommendation: Plug or otherwise seal the holes.
Item No.: 08
Site: Potable Water-
Violation: The same blue coloring was used to identify the technical water lines in the pool and spa mechanical rooms as well as the evaporator supply lines to the mineralizer that is utilized to identify the potable water lines.
Recommendation: Use a different color, or other identifying feature, to distinguish the non-potable water lines from the potable water lines.