|
|
|
Item No.:
33
|
|
Site:
Provisions-Dry Stores
|
|
Violation:
Staff are in the process of installing deck tiles throughout this area and some of the deck tiles are still missing tile grout.
|
|
Recommendation:
Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
|
|
|
Item No.:
15
|
|
Site:
Provisions-Frozen Vegetable Walk-in Freezer
|
|
Violation:
Packaged kosher meals were not labeled to identify the products as raw, cooked, or ready-to-eat. They were stored in-contact with containers of ready-to-eat foods.
|
|
Recommendation:
Ensure that food is obtained from sources that comply with applicable local, state, federal, or country of origin's statutes, regulations, and ordinances.
Ensure ready-to-eat foods are stored so they don't contact raw foods.
|
|
|
Item No.:
33
|
|
Site:
Bar-Pool Bar
|
|
Violation:
There were cracked deck tiles noted in the front bar and in the pantry of the pool bar.
|
|
Recommendation:
Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
|
|
|
Item No.:
20
|
|
Site:
Bar-Bars General
|
|
Violation:
Raw wood cocktail drink muddler utensils, labeled 'Bacardi' were used in all bars for making mojito drinks. The bare wood muddler used in the Looking Glass Bar had deep crevices along the surface, making cleaning difficult.
|
|
Recommendation:
Ensure that wood and wood wicker is not used as a food-contact surface.
|
|
|
Item No.:
36
|
|
Site:
Buffet-Starboard Aft Beverage Counter
|
|
Violation:
The artificial light level was below the minimum 220 lux required for cleaning over the beverage counter center section.
|
|
Recommendation:
Ensure that the light intensity is at least 220 Lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment, and utensil storage, pantries, toilet rooms, and consumer self-service areas.
|
|
|
Item No.:
33
|
|
Site:
Buffet-Starboard Aft Beverage Counter
|
|
Violation:
The deck at the juncture with the beverage counter was not coved, making cleaning difficult.
|
|
Recommendation:
Ensure that bulkhead and deck junctures are coved (including galleys, pantries, deck/counter junctures at buffets, bars, waiter stations, and dining room work counters).
|
|
|
Item No.:
16
|
|
Site:
Buffet-Starboard Aft Beverage Counter
|
|
Violation:
The two full milk pitchers on ice at the beverage counter were posted on time control with a label affixed giving a time of 12:00 pm. The milks were observed at 12:15 pm. Staff stated this was the time placed on the line, rather than a discard time. A time log was found in the cabinet below with times written in for previous days with the words in and out, but there was no notation for the milk on display today. Additionally, staff stated at the end of the 4 hour time period the entire pitcher is washed and refilled immediately, but during busy service periods this may be difficult. There was no spare pitchers stored clean in the dishwash for such a case.
|
|
Recommendation:
If time only, rather than time in conjunction with temperature, is used as the public health control for a working supply of potentially hazardous food before cooking, or for ready-to-eat potentially hazardous food that is displayed or held for service for immediate consumption, ensure that (1) The food is marked or otherwise identified to indicate the time that is 4 hours past the point in time when the food is removed from temperature control; (2) The food is cooked and served, served if ready-to-eat, or discarded, within 4 hours from the time when the food is removed from temperature control; and (3) The food in unmarked containers or packages or marked to exceed a 4 hour limit is discarded.
Provide two spare pitchers in the dishwash clean storage for use when the 4 hour time is reached.
|
|
|
Item No.:
30
|
|
Site:
Buffet-Portable Handwash Stations
|
|
Violation:
The portable handwash stations at the two buffet sections were equipped with a box of facial towels, rather than paper towels for hand-drying.
|
|
Recommendation:
Ensure that a handwashing facility includes a sink, soap dispenser, single-use towels dispenser, and waste receptacle.
|
|
|
Item No.:
16
|
|
Site:
Galley-Lido - Hot Galley
|
|
Violation:
There was a large bin of raw cod fish and a large bin of raw parmesan coated chicken breast with 7-day discard labels affixed to the side, but staff stated these products were actually on time only as a public health control.
|
|
Recommendation:
Ensure that all potentially hazardous foods controlled by time alone are labeled with the 4 hour discard and previous 7-day discard labels are removed.
|
|
|
Item No.:
24
|
|
Site:
Pantry-Deck 8 Aft Pantry
|
|
Violation:
The bucket filled with sanitizing rinse water had a free chlorine residual of over 400 ppm, based on a dilution test.
|
|
Recommendation:
Ensure that a chlorine solution used as a sanitizing solution has a concentration between 50 mg/L (ppm) and 200 mg/L (ppm).
|
|
|
Item No.:
22
|
|
Site:
Pantry-Deck Pantries - General
|
|
Violation:
The Hobart model FX40 undercounter dishwash machines did not have manufacturers data plates affixed to the exteriors. Staff identified these and 4 other model dishwashers throughout the ship without data plates and placed an order for same on 13 June, 2007.
|
|
Recommendation:
Ensure that warewashing machines are provided with an easily accessible and readable data plate affixed to the machine by the manufacturer that indicates the machine's design and operating specifications including the: (1) Temperatures required for washing, rinsing, and sanitizing; (2) Pressure required for the fresh water sanitizing rinse; and (3) Conveyor speed for conveyor machines or cycle time for stationary rack machines.
|
|
|
Item No.:
08
|
|
Site:
Food Service General-Ice Machines - Cross-Connection Control
|
|
Violation:
The potable water feed line to all the ice machines was protected from backflow with a Watts model S8 preventer, which is only approved for non-continuous pressure applications. The water inlet to the interior water bath did not provide a sufficient air gap to prevent backflow at that position either.
|
|
Recommendation:
Install continuous pressure backflow prevention devices on all the ice machines which now have S8 model preventers.
|
|
|
Item No.:
20
|
|
Site:
Galley-Galley - Food Probe Thermometers
|
|
Violation:
Approximately 8 worker food thermometers were verified for accuracy and 5 were out of calibration from 4-10 °F.
|
|
Recommendation:
|
|
|
Item No.:
21
|
|
Site:
Galley-Crew Galley - Dirty Dish Pass-Thru
|
|
Violation:
Missing sealant was noted along the lower portion of the dirty dishware pass-thru window, and an open void was present at the door latch channel, providing a collecting point for soil.
|
|
Recommendation:
|
|
|
Item No.:
28
|
|
Site:
Other-Officer's Mess
|
|
Violation:
Clean dishware was stored on the dirty staging rack and there was no active work at the time of the inspection.
|
|
Recommendation:
Ensure that cleaned equipment and utensils, laundered linens, and single-service and single-use articles are stored: (1) In a clean, dry location; (2) Where they are not exposed to splash, dust, or other contamination; and (3) At least 150 mm (6 inches) above the deck.
|
|