Skip directly to site content Skip directly to page options

Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: MS Fram Cruise Line: Hurtigruten Expedition Cruises AS Inspection Date: 10/09/2007 Inspection Score: 93
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 01
Site: Medical-
Violation: The vessel attempted to make a report of gastrointestinal illness but this report was not received. The vessel was using an inappropriate template. Attempts were made to request a new template but not in accordance with the recently established security features.
Recommendation: Ensure that the master, the medical staff, or other designated staff of a vessel destined for a U.S. port from a foreign port submits at least one standardized gastrointestinal illness report based on the number of reportable cases in the gastrointestinal illness log to the VSP no less than 24 hours, but not more than 36 hours before the vessel's expected arrival at the U.S. port.
Item No.: 02
Site: Medical-
Violation: While the new crew were verbally questioned as to gastrointestinal illness symptoms there was no documentation of this.
Recommendation: Ensure that reportable cases of gastrointestinal illness include crew members with a symptom onset time of up to 3 days before boarding the vessel. Maintain documentation of the 3 day assessment, for each crew member WITH SYMPTOMS, on the vessel and make available for review during inspections.
Item No.: 02
Site: Medical-
Violation: A shipping container and labels were not available on the vessel. These materials were on order.
Recommendation: Ensure that at least 10 clinical specimen collection containers for both viral and bacteriological agents (10 each), as well as the proper shipping containers and labels for same, are maintained by the medical staff.
Item No.: 08
Site: Buffet-Buffet Station
Violation: A backflow protection device was not noted at the coffee machine potable water supply line.
Recommendation: Ensure that a continuous pressure-type backflow preventer is installed when a valve is located downstream from the backflow preventer.
Item No.: 08
Site: Potable Water-AC Rooms
Violation: The potable water lines in the AC rooms 6.2 and 5.1 were not striped blue.
Recommendation: Ensure that potable water piping and fittings are painted or stripped auxiliary blue, or in accordance with ISO 14726, at 5 m (15 feet) intervals on each side of partitions, decks, and bulkheads in all spaces, except where the decor would be marred by such markings.
Item No.: 08
Site: Potable Water-Potable Water Hoses
Violation: The potable water hoses were not marked "Potable Water Only."
Recommendation: Ensure that potable water hoses are labeled for use with the words "potable water only" in letters at least 13mm (0.5 inch) at each connecting end.
Item No.: 08
Site: Potable Water-Hose Locker
Violation: The was no marked storage locker for the potable water hoses.
Recommendation: Ensure that potable water hose lockers are marked "POTABLE WATER HOSE AND FITTING STORAGE" in letters at least 13 mm (0.5 inch) high. Ensure that the potable water hose lockers are mounted at least 460 mm (18 inches) above the deck and are self-draining.
Item No.: 08
Site: Potable Water-
Violation: Non-continuous pressure backflow protection devices were noted on the water lines supplying beverage dispensers, detergent dispensers with hose connections, combination ovens and other fixtures that were under continuous water pressure. These devices were also noted on the potable water lines supplying passenger and crew laundry machines.
Recommendation: Ensure that a continuous pressure-type backflow preventer is installed when a valve is located downstream from the backflow preventer.
Item No.: 08
Site: Galley-Potwash Station
Violation: A backflow protection device was not provided for the potwash machine.
Recommendation: Ensure that a continuous pressure-type backflow preventer is installed when a valve is located downstream from the backflow preventer.
Item No.: 10
Site: DO NOT USE (whirlpool/spa)-
Violation: The sedimentation test for the whirlpools/spa was not performed for September.
Recommendation: Ensure that the granular filters are opened at least monthly and examined for cracks, mounds, or holes in the filter media and a core sample of the filter media is inspected for excessive organic material accumulation using a recommended sedimentation method.
Item No.: 11
Site: Medical-
Violation: A fact sheet on personal hygiene and handwashing was not provided to an ill passenger during the current cruise. A system was not in place for doing this.
Recommendation: Ensure that symptomatic passengers meeting the defintion for AGE are provided handwashing tips and personal hygiene information.
Item No.: 16
Site: Food Service General-
Violation: There was no indication that the cold smoked fish was frozen to the time and temperature required for parasite destruction.
Recommendation: Before service in ready-to-eat form, ensure that raw, raw-marinated, partially cooked, or marinated-partially cooked fish other than molluscan shellfish: (1) Are frozen throughout to a temperature of -20°C (-4°F) or below for 168 hours (7 days) in a freezer; or -35°C (-31°F) or below for 15 hours in a blast freezer.
Item No.: 16
Site: Galley-Bistro Cold Galley
Violation: The following foods were tested and found within the temperature danger zone in the left upright refrigeration unit: Pasta Salad 54°F, Macaroni Salad 56°F, Herring 50°F, Tuna 50°F and Potato Salad 50°F. All of these foods had been placed in the unit the day before and were discarded. The unit's integral thermometer noted 3.3°C while the thermometer placed in the unit noted 9°C. This unit was placed out of order.
Recommendation: Except during preparation, cooking, or cooling, or when time is used as the public health control, ensure that potentially hazardous food is maintained: (1) At 60°C (140°F) [roasts 54°C (130°F)] or above, or (2) At 5°C (41°F) or less.
Item No.: 19
Site: Food Service General-
Violation: Two fly electrocution devices were noted in areas where contamination of food could occur. One was over hot hold cabinets in the galley and the other was in the dry stores room over sacks of flour. These units were moved.
Recommendation: Ensure that the insect devices are not located over food storage, preparation, and service areas and dead insects and insect fragments are prevented from being impelled onto or falling on exposed food.
Item No.: 19
Site: Buffet-Buffet Station
Violation: A sneeze guard was not provided for the crackers. Side sneeze shields were not provided.
Recommendation: Ensure that food on display is protected from contamination by the use of packaging; counter, service line, or salad bar food guards; display cases; or other effective means. Provide side sneeze shields.
Item No.: 19
Site: Buffet-Crew and Officer's Mess
Violation: An indirect connection was not provided between the waste line of the utility sink and the waste water system.
Recommendation: Ensure that drain lines from all fixtures, sinks, appliance, compartments, refrigeration units, or devices that are used, designed for, or intended to be used in the preparation, processing, storage, or handling of food, ice or drinks shall be indirectly connected to appropriate waste systems by means of an air-gap or air-break.
Item No.: 20
Site: Galley-Ice Machine Station
Violation: Slotted fasteners were noted in the upper compartment of the ice machine, making cleaning difficult.
Recommendation: Replace these slotted fasteners with smooth low-profile non-corroding fasteners.
Item No.: 20
Site: Galley-Bistro Galley
Violation: Slotted fasteners were noted on the inside surfaces of the kettles lids, making cleaning difficult.
Recommendation: Replace these slotted fasteners with smooth low-profile non-corroding fasteners.
Item No.: 21
Site: Food Service General-
Violation: The non-food contact surfaces of equipment were difficult to clean due to limited space between pieces of equipment and limited space between equipment and the counter. This was noted in the galley between the fryers and at the beverage counters under the coffee machines and ice dispensers.
Recommendation: Ensure that equipment that is fixed because it is not easily movable is installed so that it is: (1) Spaced to allow access for cleaning along the sides, behind, under and above the equipment; (2) Spaced from adjoining equipment, bulkhead, and deckhead at a distance of not more than 0.8 millimeter or 1/32 inch; or (3) Sealed to adjoining equipment or bulkhead, if the equipment is exposed to spillage or seepage. Ensure that table-mounted equipment that is not easily movable is installed to allow cleaning of the equipment and areas underneath and around the equipment by being: (1) Sealed to the table; or (2) Elevated on legs.
Item No.: 21
Site: Galley-Bistro Galley
Violation: The wires and supply lines for the ovens were draped in between the two ovens, making cleaning difficult.
Recommendation: Ensure that these wires are attached in such a way as to not obstruct cleaning.
Item No.: 21
Site: Bar-Deck 7 Bar
Violation: A gap was noted on the right side of the counter top above the undercounter glass washer.
Recommendation: Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 21
Site: Galley-Ice Machine Station
Violation: The drain line for the unit was ribbed and the supply lines were braided stainless steel, making cleaning difficult.
Recommendation: Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 21
Site: Buffet-Buffet Station
Violation: A small hole was noted on the side of the buffet station at the end of the buffet on the passenger side.
Recommendation: Seal the hole.
Item No.: 21
Site: Buffet-Buffet Station
Violation: The decorative laminate surfaces were damaged at the entrance to service side of the buffet.
Recommendation: Repair the decorative laminate surfaces.
Item No.: 21
Site: Buffet-Crew and Officer's Mess-Beverage Station
Violation: The electrical wires draped the counter, making cleaning difficult.
Recommendation: Ensure the electrical wires are not draped across the counter.
Item No.: 21
Site: Buffet-Beverage Station
Violation: Gaps were noted around the cabinet penetrations under the beverage stations, making cleaning difficult.
Recommendation: Profile these gaps around the cabinet penetrations.
Item No.: 21
Site: Provisions-Cargo Holds
Violation: Difficult to clean wooden pallets were noted.
Recommendation: Replace these wooden pallets with plastic or some other easy to clean material.
Item No.: 21
Site: Provisions-
Violation: A few metal shelving units were noted that were difficult to clean due to gaps and seams.
Recommendation: Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 22
Site: Galley-Potwash Station
Violation: The pans were improperly loaded in the machine. The pans and lids were stacked blocking the water spray.
Recommendation: Ensure that soiled items to be cleaned in a warewashing machine are loaded into racks, trays, or baskets or onto conveyors in a position that: (1) Exposes the items to the unobstructed spray from all cycles; and (2) Allows the items to drain.
Item No.: 28
Site: Galley-Potwash Station
Violation: A crew member was noted drying pans with a clean dry cloth.
Recommendation: After cleaning and sanitizing, ensure that equipment and utensils are air-dried or adequately drained before contact with food.
Item No.: 28
Site: Galley-Potwash Station
Violation: An indirect connection was not provided between the waste line of the 3-compartment sink and the waste water system.
Recommendation: Ensure that all drain lines from warewashing sinks or machines drain through an air-gap or air-break to a drain or scupper.
Item No.: 29
Site: Bar-Deck 7 Bar
Violation: The handwash station was more than eight meters away from the furthest preparation counter.
Recommendation: Ensure that the handwashing facility is located within 8 m (25 feet) of all parts of the area and is not located in an adjacent area that requires passage through a closed door. where the user makes hand contact with the door.
Item No.: 30
Site: Pantry-Bistro Pantry
Violation: A waste receptacle was not provided at the handwash sink.
Recommendation: Provide a waste receptacle for this handwash sink.
Item No.: 30
Site: Galley-Bistro-Chef's Toilet room
Violation: The door was not self-closing. Toilet tissue was not provided. A "wash hands often" was not posted over the handwash sink. A "wash hands after using the toilet" sign was not posted on the bulkhead near the door.
Recommendation: Ensure that toilet rooms are completely enclosed and shall have tight-fitting, self-closing doors which shall be kept closed except during cleaning or maintenance. Ensure that a sign stating "WASH HANDS OFTEN" in a language that the food employees understand is posted over handwashing sinks. Ensure that signs are conspicuously posted on the bulkhead adjacent to the door of the toilet, reading "WASH HANDS AFTER USING TOILET " in a language that the food employees understand. Ensure that a supply of toilet tissue is provided at each toilet at all times.
Item No.: 33
Site: Galley-Bistro
Violation: Inadequate space for cleaning was noted between the cook station and bulkhead and between the fryer and the bulkhead.
Recommendation: Ensure equipment is positioned to allow for adequate cleaning.
Item No.: 33
Site: Other-Dining Room Head Waiter Station
Violation: The counter-deck juncture was not coved.
Recommendation: Ensure that bulkhead and deck junctures are coved (including galleys, pantries, deck/counter junctures at buffets, bars, waiter stations, and dining room work counters).
Item No.: 33
Site: Other-Dining Room and Buffet Stations
Violation: Seams were noted between the wood planks on the deck in front of the waiter stations and buffet making cleaning difficult. The cove base was constructed of wood. Water damaged was noted along the seams between the cove sections. The juncture between the bottom of the cove base and the deck was a 90° angle, making cleaning difficult.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
Item No.: 33
Site: Food Service General-Bistro
Violation: Small seams were noted between the equipment leg plates and the deck, making cleaning difficult.
Recommendation: Seal the seams between the equipment legs and the deck plates.
Item No.: 33
Site: Buffet-Bistro
Violation: Small bits of loose grout were noted on the deck under the cleaning locker.
Recommendation: Ensure that decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, are cleaned as often as necessary.
Item No.: 33
Site: Buffet-Bistro
Violation: Open voids were noted in the door frames.
Recommendation: Seal these open door frame voids.
Item No.: 33
Site: Buffet-Bistro
Violation: Coving was not provided at the deck-bulkhead juncture behind the buffet and service lines
Recommendation: Ensure that bulkhead and deck junctures are coved (including galleys, pantries, deck/counter junctures at buffets, bars, waiter stations, and dining room work counters).
Item No.: 33
Site: Buffet-Bistro
Violation: A hole was noted in the bulkhead near the handwash sink.
Recommendation: Seal the hole.
Item No.: 33
Site: Provisions-Cargo Hold 2
Violation: A partial wall constructed of painted wood and chicken wire fencing was noted. These materials were difficult to clean.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
Item No.: 33
Site: Buffet-Crew and Officer's Mess
Violation: The deck-counter juncture was not coved, making cleaning difficult.
Recommendation: Ensure that bulkhead and deck junctures are coved (including galleys, pantries, deck/counter junctures at buffets, bars, waiter stations, and dining room work counters).
Item No.: 33
Site: Buffet-Crew and Officer's Buffet and Beverage Station
Violation: There was limited access to the deck under the buffet and beverage station, making cleaning difficult. The deck drain under the cold station was soiled.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning. Ensure that decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, are cleaned as often as necessary.
Item No.: 33
Site: Provisions-Cargo Holds
Violation: The bulkheads were difficult to clean due to the lashing bracket system. The deckheads were difficult to clean due to the partial false ceiling system.
Recommendation: Ensure that light fixtures, vent covers, and similar equipment attached to the bulkheads or deckheads are easily cleanable.
Item No.: 36
Site: Buffet-Bistro
Violation: The deckhead mounted fluorescent bulbs behind the line were not shielded or shatter-resistant.
Recommendation: Ensure that light bulbs are shielded, coated, or otherwise shatter-resistant in areas where there is exposed food, clean equipment, utensils, and linens, or unwrapped single-service and single-use articles.
Item No.: 36
Site: Other-Dining Room Head Waiter Station
Violation: The light bulbs over clean equipment were not shielded or shatter-resistant.
Recommendation: Ensure that light bulbs are shielded, coated, or otherwise shatter-resistant in areas where there is exposed food, clean equipment, utensils, and linens, or unwrapped single-service and single-use articles.
Item No.: 40
Site: Integrated Pest Management-
Violation: The integrated pest management plan did not mention night time monitoring, and there was no documentation of training for ship staff.
Recommendation: Ensure that each vessel develops an Integrated Pest Management Plan to address effective monitoring and control strategies for pests aboard the vessel. Ensure that the Integrated Pest Management Plan sets a schedule for periodic monitoring inspections including some at night. Ensure that the training of the pest-control personnel is documented in the Integrated Pest Management Plan.
Item No.: 41
Site: Housekeeping-
Violation: The outbreak prevention and response plan did not provide a trigger for action, responsibilities of departments and staff or a disinfection frequency for public areas to include high hand contact areas.
Recommendation: Ensure that each vessel has a written Outbreak Prevention and Response Plan (OPRP) which details the standard procedures and policies to specifically address gastrointestinal illness onboard. The plan shall include the duties and responsibilities of each department and their staff to include steps in outbreak management and control as well as the trigger for each step.
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program