Item No.:
08
|
|
Site:
Potable Water-Piano Bar Pantry
|
|
Violation:
The vent for the backflow prevention device was plugged with duck tape. This device was installed on the potable water line for the Ecolab chemical dispensers. This was corrected during the inspection.
|
|
Recommendation:
Unplug the vent for the backflow prevention device.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Steering Room
|
|
Violation:
The potable water line for the chemical feed line was not striped blue. This was corrected during the inspection.
|
|
Recommendation:
Ensure that potable water piping and fittings are painted or striped auxiliary blue, or in accordance with ISO 14726, at 5 m (15 feet) intervals on each side of partitions, decks, and bulkheads in all spaces, except where the decor would be marred by such markings.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Cold Pantry Deck 4
|
|
Violation:
There was a non-continuous pressure backflow prevention device installed on the potable water line serving the coffee machine.
|
|
Recommendation:
Ensure that a continuous pressure-type backflow preventer is installed when a valve is located downstream from the backflow preventer.
|
|
|
Item No.:
16
|
|
Site:
Buffet-Time As A Public Health Control Plan
|
|
Violation:
The time as a public health control plan only stated the set-up and discard times. The plan did not indicate when the food goes on time control.
|
|
Recommendation:
Ensure the time as a public health control plan indicates when the food goes on time control.
|
|
|
Item No.:
28
|
|
Site:
Galley-Garde Manger
|
|
Violation:
There were a few small plastic bins stacked together on the clean racks, impeding air drying.
|
|
Recommendation:
Ensure that clean equipment and utensils are stored: (1) In a self-draining position that allows air drying; and (2) Covered or inverted.
|
|
|
Item No.:
33
|
|
Site:
Galley-Saucier
|
|
Violation:
There was recessed and missing grout noted on the decks along the scupper, making cleaning difficult.
|
|
Recommendation:
Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
|
|
|
Item No.:
20
|
|
Site:
Galley-Saucier
|
|
Violation:
Slotted fasteners were noted in the deep fat fryer, making cleaning difficult.
|
|
Recommendation:
Remove the slotted fasteners and replace them with smooth low-profile non-corroding fasteners.
|
|
|
Item No.:
21
|
|
Site:
Galley-Saucier
|
|
Violation:
There were a few holes on the stand for the combination oven, making cleaning difficult.
|
|
Recommendation:
Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
22
|
|
Site:
Galley-Dishwash
|
|
Violation:
There was an excessive amount of water leaking from the edge of the dishwash machine onto the deck, right after the final rinse curtain.
|
|
Recommendation:
Seal the edge of the dishwash macine.
|
|
|
Item No.:
17
|
|
Site:
Galley-Pastry
|
|
Violation:
Per the chef, cheesecakes and custards were made on the ship. These items were baked and then cooled in the freezer. However, the cooling process was not recorded on a log.
|
|
Recommendation:
Ensure that logs documenting cooked, potentially hazardous food cooling temperatures and times from the starting points designated in 7.3.5.2.1 thru the control points at 2 and 6 hours are maintained onboard the vessel for a period of 30 days form the date the food was placed in the cooling process.
Ensure that logs documenting cooling of potentially hazardous foods prepared from ingredients at ambient temperatures, with the start time to the time when 5°C (41 °F) is reached are also maintained for a period of 30 days, beginning with the day of preparation.
|
|
|
Item No.:
41
|
|
Site:
Housekeeping-Outbreak Prevention and Response Plan
|
|
Violation:
Per the staff, public areas were disinfected every 2 hours during an outbreak. However, the outbreak prevention and response plan did not state the frequency of disinfection of the public areas.
|
|
Recommendation:
Ensure the outbreak prevention and response plan is amended to reflect the actual operations of the vessel.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Fecal Accident Plan
|
|
Violation:
The fecal accident plan indicated that a 200ppm halogenation would occur for ten minutes for both loose and formed stool. This would result in a concentration value of 2000. A concentration value of 9600 was required to eliminate cryptosporidium in loose stools.
|
|
Recommendation:
Ensure that a fecal accident response procedure, which meets or exceeds the procedure provided in annex 13.11, is documented and available for review during inspections.
|
|
|
Item No.:
08
|
|
Site:
Medical-Ward
|
|
Violation:
The shower in the medical ward did not have a backflow prevention device. The flexible shower head could reach the toilet, deck drain and the sink.
|
|
Recommendation:
Ensure the appropriate non-continuous backflow prevention device is installed on this line.
|
|
|
Item No.:
33
|
|
Site:
Provisions-Beverage Stores
|
|
Violation:
The deck beneath the beverage stands were heavily soiled with an accumulation of dust, debris and packaging.
|
|
Recommendation:
Ensure that decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, are cleaned as often as necessary.
|
|
|
Item No.:
19
|
|
Site:
Provisions-Liquor Store
|
|
Violation:
Liquor boxes and bare bottles were stored directly on the deck.
|
|
Recommendation:
Ensure that food is protected from contamination by storing the food: (1) In a clean, dry location; (2) Where it is not exposed to splash, dust, or other contamination; and (3) At least 15 centimeters (6 inches) above the deck.
|
|
|
Item No.:
33
|
|
Site:
Bar-Main
|
|
Violation:
The deck inside the technical space was heavily soiled with an accumulation of rust, dirt and general debris.
|
|
Recommendation:
Ensure that decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, are cleaned as often as necessary.
|
|