Skip directly to site content Skip directly to page options

Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: Costa Mediterranea Cruise Line: Costa Crociere S.P.A. Inspection Date: 12/25/2007 Inspection Score: 97
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 08
Site: Potable Water-Cross Connection Control Program
Violation: During the inspection, the backflow prevention devices for the hoses on the whirlpool tubs in the passenger suites could not be viewed.
Recommendation: Ensure that backflow preventers are located so they may be inspected, serviced, and maintained.
Item No.: 08
Site: Potable Water-Cross Connection Control Program
Violation: The air gaps for the Ecolab chemical mixing units were not on the list of air gaps.
Recommendation: List the air gaps for these units.
Item No.: 10
Site: DO NOT USE (whirlpool/spa)-Officer's Whirlpool Tubs
Violation: The whirlpool tubs in the Captain's and Chief Engineer's cabins were cleaned with a 3-bucket system each week, but the recirculation system was not disinfected as part of the cleaning.
Recommendation: Ensure that private whirlpool spas located in individual passenger cabins are cleaned and disinfected, including associated recirculation systems, between occupancies or weekly, whichever is more frequent.
Item No.: 16
Site: Galley-Cooling Logs
Violation: There were 2 items on the cooling logs (beef, lasagna) that were placed in the blast chiller at a temperature of 130°F and 136°F, respectively.
Recommendation:
Item No.: 18
Site: Provisions-Provisions - Fish Preparation Freezer
Violation: A few packages of raw cod were stored on top of packages of cooked shrimp. This item was corrected during the inspection.
Recommendation: Ensure that food is protected from cross-contamination by: (1) Physically separating raw animal foods during storage, preparation, holding, and display from raw ready-to-eat food including other raw animal food such as fish for sushi or molluscan shellfish, or other raw ready-to-eat food such as vegetables, and cooked ready-to-eat food; so products do not physically touch, and so as to prevent dripping of one product into another.
Item No.: 21
Site: Buffet-Pizzaria Buffet Line
Violation: There was a penetration for wires in the back of the technical compartment that was not sealed. This was in the 3rd technical compartment from the entrance.
Recommendation: Seal the opening around the wire penetrations through the back of the technical compartment.
Item No.: 22
Site: Galley-Potwash
Violation: The temperature gauge for the final rinse on the potwash machine was stuck at 170°F.
Recommendation: Repair the temperature gauge on the potwash machine.
Item No.: 24
Site: Galley-Main Galley - Potwash Area - Starboard Side
Violation: The sanitizer concentration in the sanitizer compartment of the three-compartment sink operation was less than 50 ppm. According to ship personnel, the policy is to maintain the concentration at 50 ppm. This item was corrected during the inspection.
Recommendation: Ensure that a chlorine solution used as a sanitizing solution has a concentration between 50 mg/L (ppm) and 200 mg/L (ppm).
Item No.: 26
Site: Galley-Main Galley - Garde Manger
Violation: The previously cleaned strainer basket to the salad machine was slight soiled with a fibrous or paper-like material. This item was corrected during the inspection.
Recommendation: Ensure that food-contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 33
Site: Provisions-Provisions - Walk-in Freezer
Violation: Loose, peeling sealant was noted on the bulkhead in this area. This item was corrected during the inspection.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas, are maintained in good repair.
Item No.: 34
Site: Provisions-Provisions - Water Walk-in Refrigerator
Violation: A small water leak was noted in the deckhead. The source of the water leak was unknown at the time of the inspection.
Recommendation: Ensure that a plumbing system in a food area is maintained in good repair.
*Inspections scores of 85 or lower are NOT satisfactory