Item No.:
05
|
|
Site:
Potable Water-Potable Water - Distribution Far Point Calibration
|
|
Violation:
The distribution halogen concentration was measured at 1.93 ppm by both the inspector and the ship's engineer using similar equipment. The far point analyzer read 1.10 ppm. The analyzer was 0.83 ppm out of calibration.
|
|
Recommendation:
Ensure that the free residual halogen measured by the halogen analyzer is ±0.2 mg/L (ppm) of the free residual halogen measured by the manual test.
|
|
|
Item No.:
06
|
|
Site:
Potable Water-Potable Water - Distribution Charts
|
|
Violation:
The distribution charts did not have a range of 0 - 5 ppm. The charts used were 0 - 100 ppm and required the use of a conversion chart to deternmine halogen levels.
|
|
Recommendation:
Ensure that the halogen analyzer-chart recorder charts have a range of 0.0 to 5.0 mg/L (ppm) and have a recording period of 24 hours.
|
|
|
Item No.:
06
|
|
Site:
Potable Water-Potable Water - Halogen Analyzer Charts for Production and Bunkering
|
|
Violation:
The halogen analyzer charts used for recording both bunkering and production did not have a range of 0 - 5 ppm. The charts required a conversion table to determine halogen concentration.
|
|
Recommendation:
Ensure that the halogen analyzer-chart recorder charts have a range of 0.0 to 5.0 mg/L (ppm) and have a recording period of 24 hours.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Potable Water - Cross Connection Control Program
|
|
Violation:
On a few pieces of equipment and potable water pipes, the cross connection control program documents listed the incorrect type of backflow prevention device. There were no results made available on the testable backflow prevention devices, such as the International Shore Connections.
|
|
Recommendation:
Ensure that the cross-connection control program includes at minimum: a complete listing of cross-connections and the backflow prevention method/device for each, so that there is a match to the plumbing system component and location, and an inspection frequency. Ensure that air-gaps are included in the listing.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Swimming Pool and Whirlpool Spa
|
|
Violation:
The pool and whirlpool spa drain covers appear to have an anti-entrapment design, but they are not stamped as certified units and there is no written documentation attesting to the certification. This is a repeat violation.
|
|
Recommendation:
Ensure that anti-entrapment drain covers or other drains that prevent entrapment hazards as specified in U.S. Consumer Product Safety Publication 363-009801 (dual drains/channel drains) are provided on swimming pools and whirlpool spas. Ensure that drain covers have either the plumbing/engineering approving organization stamp and flow rate affixed to the cover, or that a letter is maintained aboard the vessel certifying that the cover meets the safety requirements outlined in AMSE/ANSI A112.19.8M or an equivalent standard.
|
|
|
Item No.:
15
|
|
Site:
Galley-Main Galley - Dry Storage Cabinet
|
|
Violation:
Two large cans of food were found dented. One can was dented along the top seam; the other had a large dent in the side of the can. These items were discarded.
|
|
Recommendation:
Ensure that food packages are in good condition and protect the integrity of the contents so that the food is not exposed to adulteration or potential contaminants. Ensure that canned goods with dents on end or side seams are not used.
|
|
|
Item No.:
16
|
|
Site:
Galley-Veranda - Pantry
|
|
Violation:
A few containers of yogurt found inside the day refrigerator had internal product temperatures of 55-60 °F. These items were discarded.
|
|
Recommendation:
Except during preparation, cooking, or cooling, or when time is used as the public health control, ensure that potentially hazardous food is maintained: (1) At 60°C (140°F) [roasts 54°C (130°F)] or above, or (2) At 5°C (41°F) or less.
|
|
|
Item No.:
16
|
|
Site:
Galley-Veranda - Pantry
|
|
Violation:
According to Food and Beverage personnel, items placed out on the buffet were placed back in the day refrigerator at the end of the meal period (e.g., sealed containers of yogurt). These items were left on the buffet for approximately 2 hours. These items were listed on the time as a public health control plan logs as under time control. These items were discarded.
|
|
Recommendation:
If time only, rather than time in conjunction with temperature, is used as the public health control for a working supply of potentially hazardous food before cooking, or for ready-to-eat potentially hazardous food that is displayed or held for service for immediate consumption, ensure that (1) The food is marked or otherwise identified to indicate the time that is 4 hours past the point in time when the food is removed from temperature control; (2) The food is cooked and served, served if ready-to-eat, or discarded, within 4 hours from the time when the food is removed from temperature control; and (3) The food in unmarked containers or packages or marked to exceed a 4 hour limit is discarded.
|
|
|
Item No.:
20
|
|
Site:
Galley-Veranda - Port Services Area
|
|
Violation:
The grill grease pan chute and housing were difficult to clean due to the length of the void and chutes on the front and back panels. This equipment is due to be replaced at the upcoming drydock.
|
|
Recommendation:
Ensure that multiuse food-contact surfaces are: (1) Smooth; (2) Free of breaks, open seams >1 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices; (4) Finished to have smooth welds and joints; and (5) Accessible for cleaning and inspection by one of the following methods without being disassembled, by disassembling without the use of tools, or by easy disassembling with the use of handheld tools commonly available to maintenance and cleaning personnel such as screwdrivers, pliers, open-end wrenches, and Allen wrenches.
|
|
|
Item No.:
20
|
|
Site:
Food Service General-Food Service General - Ice Machines
|
|
Violation:
Slotted fasteners were noted in the water contact areas of the ice cuber section of several of the the ice machines. This is a repeat item from the previous inspection.
|
|
Recommendation:
Ensure that multiuse food-contact surfaces are: (1) Smooth; (2) Free of breaks, open seams >1 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices; (4) Finished to have smooth welds and joints; and (5) Accessible for cleaning and inspection by one of the following methods without being disassembled, by disassembling without the use of tools, or by easy disassembling with the use of handheld tools commonly available to maintenance and cleaning personnel such as screwdrivers, pliers, open-end wrenches, and Allen wrenches.
|
|
|
Item No.:
20
|
|
Site:
Galley-Main Galley
|
|
Violation:
Excess sealant was noted at the top of the ice bin, making cleaning difficult.
|
|
Recommendation:
Remove excess sealant from the top of the ice bin. If sealant is needed in this area, ensure that it is applied in a smooth, easily cleanable fashion.
|
|
|
Item No.:
20
|
|
Site:
Galley-Main Galley - Potwash Area
|
|
Violation:
One cooking pan coating was deteriorated, making cleaning difficult.
|
|
Recommendation:
Ensure that materials used in the construction of multiuse utensils and food-contact surfaces of equipment are: (1) Durable, corrosion-resistant, and nonabsorbent; (2) Sufficient in weight and thickness to withstand repeated warewashing; (3) Finished to have a smooth, easily cleanable surface; and (4) Resistant to pitting, chipping, crazing, scratching, scoring, distortion, and decomposition.
|
|
|
Item No.:
21
|
|
Site:
Galley-Main Galley - Hot Galley
|
|
Violation:
A hole was noted in one of the legs of the stainless steel countertop, leaving an opening where food and dirt could collect, making cleaning difficult.
|
|
Recommendation:
Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
21
|
|
Site:
Preparation Room-Provisions - Butcher Shop
|
|
Violation:
The doors to some of the undercounter refrigerators did not seal properly.
|
|
Recommendation:
Ensure that non-food contact equipment is maintained in good repair and proper adjustment including: (1) Equipment maintained in a state of repair and condition that meets the materials, design, construction, and operation specifications of these guidelines. (2) Equipment components such as doors, seals, hinges, fasteners, and kick plates are kept intact, tight, and adjusted in accordance with manufacturer's specifications.
|
|
|
Item No.:
21
|
|
Site:
Galley-Main Galley
|
|
Violation:
The gasket to refrigerator #3 was split, making cleaning difficult.
|
|
Recommendation:
Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
21
|
|
Site:
Galley-Main Galley - Undercounter Refrigerator #11
|
|
Violation:
The door gasket was loose, leaving a gap, making cleaning difficult.
|
|
Recommendation:
Ensure that nonfood-contact equipment components such as doors, seals, hinges, fasteners, and kick plates are kept intact, tight, and adjusted in accordance with manufacturer's specifications.
|
|
|
Item No.:
21
|
|
Site:
Galley-Main Galley - Potwash Area
|
|
Violation:
One pan was missing a handle, leaving holes, making cleaning diffcult.
|
|
Recommendation:
Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
22
|
|
Site:
Pantry-Deck 2 Room Service
|
|
Violation:
The undercounter dishwasher was posted out of order.
|
|
Recommendation:
Repair the undercounter dishwasher.
|
|
|
Item No.:
24
|
|
Site:
Galley-Veranda - Dishwash Area
|
|
Violation:
The in-use dishwasher final sanitizing rinse (chlorine) concentration measured well below 50 ppm on several occassions. The unit was tested with different test strips maintained on the ship, as well as test strips of the inspector. The unit was adjusted to obtain the proper sanitizer concentration.
|
|
Recommendation:
Ensure that a chlorine solution used as a sanitizing solution has a concentration between 50 mg/L (ppm) and 200 mg/L (ppm).
|
|
|
Item No.:
26
|
|
Site:
Galley-Main Galley
|
|
Violation:
Eight previously cleaned plates and bowls were found soiled and stored as clean.
|
|
Recommendation:
Ensure that food-contact surfaces of equipment and utensils are clean to sight and touch.
|
|
|
Item No.:
27
|
|
Site:
Galley-Main Galley - Hot Galley
|
|
Violation:
The rear non-food-contact surface of the oven was soiled with greater than one day's accumulation of dirt and food debris.
|
|
Recommendation:
Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
28
|
|
Site:
Galley-Main Galley
|
|
Violation:
Some of the clean plates, pots and pans were stored wet.
|
|
Recommendation:
Ensure that clean equipment and utensils are stored: (1) In a self-draining position that allows air drying; and (2) Covered or inverted.
|
|
|
Item No.:
33
|
|
Site:
Food Service General-Food Service General - Decks
|
|
Violation:
Some of the deck surfaces in food preparation and food storage areas were rough and peeling, especially under equipment and around equipment mounts, making cleaning difficult.
|
|
Recommendation:
Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas, are maintained in good repair.
|
|
|
Item No.:
33
|
|
Site:
Galley-Main Galley - Wine Service Area
|
|
Violation:
The deck beneath the preparation counter was rough and peeling, making cleaning difficult.
|
|
Recommendation:
Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas, are maintained in good repair.
|
|
|
Item No.:
33
|
|
Site:
Preparation Room-Provisions - Fruit Walk-in Refrigerator
|
|
Violation:
There were gaps in the deckhead, exposed piping and attached equipment, as well as exposed pipe insulation, making cleaning difficult.
|
|
Recommendation:
Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas, are maintained in good repair. Ensure that exposed utility service lines and pipes, including lines for fire detection and protection systems, are installed so they do not obstruct or prevent cleaning.
|
|
|
Item No.:
33
|
|
Site:
Other-Crew Mess Entrance
|
|
Violation:
Open channels were noted in the door area, making cleaning difficult.
|
|
Recommendation:
Seal off the open channels in the door.
|
|
|
Item No.:
33
|
|
Site:
Preparation Room-Provisions - Butcher Shop
|
|
Violation:
Gaps were noted at the bulkhead-deckhead juncture, especially in the corners. Loose profiles strips and loose and peeling sealant were also noted. There was also exposed piping and attached equipment, making cleaning difficult.
|
|
Recommendation:
Ensure that exposed utility service lines and pipes, including lines for fire detection and protection systems, are installed so they do not obstruct or prevent cleaning. Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas, are maintained in good repair.
|
|
|
Item No.:
33
|
|
Site:
Other-Crew Mess
|
|
Violation:
There was no coving at the deck-bulkhead juncture beneath the handwash station.
|
|
Recommendation:
Ensure that bulkhead and deck junctures are coved (including galleys, pantries, deck/counter junctures at buffets, bars, waiter stations, and dining room work counters).
|
|
|
Item No.:
33
|
|
Site:
Other-Main Dining Room - Dining Room Work Counter
|
|
Violation:
There was no coving at the deck-counter juncture of this station. This is a repeat item from the previous inspection.
|
|
Recommendation:
Ensure that bulkhead and deck junctures are coved (including galleys, pantries, deck/counter junctures at buffets, bars, waiter stations, and dining room work counters).
|
|
|
Item No.:
33
|
|
Site:
Galley-Main Galley
|
|
Violation:
There was no coving in some areas of the galley, especially behind equipment.
|
|
Recommendation:
Ensure that bulkhead and deck junctures are coved (including galleys, pantries, deck/counter junctures at buffets, bars, waiter stations, and dining room work counters).
|
|
|
Item No.:
36
|
|
Site:
Galley-Main Galley - Hot Galley
|
|
Violation:
The bulb inside reach-in refrigerator #4 did not appear to be shatter resistant.
|
|
Recommendation:
Ensure that light bulbs are shielded, coated, or otherwise shatter-resistant in areas where there is exposed food, clean equipment, utensils, and linens, or unwrapped single-service and single-use articles.
|
|