Cruise Ship: Seven Seas Mariner Cruise Line: Regent Seven Seas Inspection Date: 04/26/2001 Inspection Score: 92
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 10
Site: Other-WHIRLPOOL SPAS
Violation: THE HEALTH RISK SIGN AT THE SPAS DID NOT WARN AGAINST USE BY PERSONS WHO WERE IMMUNOCOMPRIMISED.
Recommendation: 6.4.1.1.3 A sign shall be installed near the whirlpool spas that lists standard safety precautions and risks, warning against use by particularly susceptible people, such as those who are immunocompromised.
Item No.: 02
Site: Other-MEDICAL
Violation: THERE WAS NO IDENTIFICATION OF CREW MEMBERS WITH GASTROINTESTINAL ILLNESS SYPMTOMS UP TO 3 DAYS PRIOR TO BOARDING THE SHIP.
Recommendation: 4.1.1.1.2 The reportable cases shall include those crew members with a symptom onset time of up to 3 days before boarding the vessel.
Item No.: 13
Site: Other-FOOD SANITATION - GENERAL
Violation: POOR KNOWLEDGE OF PROPER DISHWASHING, FOOD PROTECTION IN STORAGE/DISPLAY, GLOVE USE, AND DISHWARE STORAGE WAS NOTED IN VARIOUS AREAS BY BOTH WORKERS AND THEIR SUPERVISORS.
Recommendation: 7.2.1.2.1.12 The person in charge of the food operations on the vessel shall ensure that: (12) Employees are properly trained in food safety as it relates to their assigned duties. 7.2.1.1.1 Based on the risks of foodborne illness inherent to the food operation, during inspections and upon request the person in charge of the food operations on the vessel shall demonstrate to the VSP knowledge of foodborne disease prevention, application of the Hazard Analysis Critical Control Point principles, and the food-safety guidelines in this manual. The person in charge shall demonstrate this knowledge by compliance with these guidelines, by being a domestically or foreign certified food protection manager who has shown proficiency of required information through passing a test that is part of an accredited program, or by responding correctly to the inspector's questions as they relate to the specific food operation.
Item No.: 22
Site: Other-MAIN GALLEY - COLD PANTRY
Violation: ONE WORKER WAS NOTED WASHING, RINSING, AND SANITIZING A KNIFE IN THE THREE BUCKETS.
Recommendation: The three bucket system is intended for washing, rinsing, and sanitizing food and non-food contact of equipment which must be cleaned in place. Utensils should be cleaned and sanitized in either the dishwash machine or the 3 compartment sink.
Item No.: 18
Site: Other-MAIN GALLEY - BLAST CHILLER
Violation: RAW CHICKEN WAS FOUND ON THE TOP SHELF OF THE BLAST CHILLER AND READY-TO-EAT CANAPES AND SALAD ON THE LOWER SHELVES.
Recommendation: 7.3.3.2.1.1 Food shall be protected from cross-contamination by: (1) Physically separating raw animal foods during storage, preparation, holding, and display from raw ready-to-eat food including other raw animal food such as fish for sushi or molluscan shellfish, or other raw ready-to-eat food such as vegetables, and cooked ready-to-eat food; so products do not physically touch, and so as to prevent dripping of one product into another.
Item No.: 19
Site: Other-MAIN GALLEY - PASTRY
Violation: THERE WAS A PLASTIC COOLER WITH ICE CREAM CONTAINERS INSIDE STORED DIRECTLY ON THE DECK.
Recommendation: 7.3.3.5.1 Food shall be protected from contamination by storing the food: (1) In a clean, dry location; (2) Where it is not exposed to splash, dust, or other contamination; and (3) At least 15 centimeters (6 inches) above the deck.
Item No.: 21
Site: Other-PREPARATION ROOM - BAKERY
Violation: THERE WAS CORROSION PRESENT AT THE BASE OF THE FLOOR MIXER WHERE IT JOINED THE STAINLESS STEEL FOUNDATION.
Recommendation: 7.4.1.1.9 Nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning shall be constructed of a corrosion-resistant, nonabsorbent, and smooth material.
Item No.: 26
Site: Other-PREPARATION ROOM - BUTCHER SHOP
Violation: THE MEAT GRINDER WAS SOILED WITH FOOD DEBRIS AND STORED AS CLEAN.
Recommendation: 7.5.5.1.1 Food-contact surfaces of equipment and utensils shall be clean to sight and touch.
Item No.: 24
Site: Other-CREW GALLEY
Violation: THE FINAL SANITIZING RINSE WATER OF THE IN-USE POT WASH SINKS WAS MEASURED AT 162 °F.
Recommendation: 7.5.6.1.1 In a manual operation, if immersion in hot water is used for sanitizing: (1) The temperature of the water shall be maintained at 77°C, (171°F) or above; and (2) The food-contact surface shall be immersed for at least 30 seconds.
Item No.: 19
Site: Other-FOOD SERVICE GENERAL
Violation: NUMEROUS FOOD AREAS HAD INSECT LIGHTS DESIGNED TO ATTRACT FLYING INSECTS AND TRAP THEM ON GLUE STRIPS INSIDE. IN SOME AREAS THESE LIGHTS WERE MOUNTED OVER FOOD PREPARATION AND STORAGE COUNTERS OR OVER CLEAN UTENSIL STORAGE AREAS.
Recommendation: Move the insect lights to locations where they cannot contaminate food preparation surfaces or surfaces of cleaned dishware, equipment, or utensils.
Item No.: 22
Site: Other-TERRACE CAFÉ - POT WASH
Violation: THE WATER TEMPERATURE IN THE SANITIZING SINK WAS 205 °F, BUT THE MOUNTED THERMOMETER DISPLAYED 170°F.
Recommendation: 7.5.2.1.1 Water temperature measuring devices: (1) That are scaled in Celsius or dually scaled in Celsius and Fahrenheit shall be designed to be accurate to ±1.5°C in the intended range of use. (2) That are scaled only in Fahrenheit shall designed to be accurate to ±3°F in the intended range of use.
Item No.: 22
Site: Other-TERRACE CAFÉ - POT WASH
Violation: STEAM PRODUCED IN THE SANITIZING RINSE SINK WAS CONDENSING ON THE AIR SUPPLY VENTS ON THE DECKHEAD.
Recommendation: Adjust the sanitizing rinse sink heating element to ensure that steam release is minimized. Maintaining a water temperature between 171 and 176 °F should be sufficient.
Item No.: 28
Site: Other-TERRACE CAFÉ - DISHWASH
Violation: CLEANED PLATES, BOWLS, AND OTHER DISHES WERE STORED UPRIGHT IN THE CLEAN STORAGE RACKS, SO THE FOOD CONTACT SURFACES WERE EXPOSED TO CONTAMINATION.
Recommendation: 7.5.7.3.2 Clean equipment and utensils shall be stored: (1) In a self-draining position that allows air drying; and (2) Covered or inverted.
Item No.: 28
Site: Other-TERRACE CAFÉ - DISHWASH
Violation: OVERSPLASH FROM THE GLASSWASH MACHINE DRAIN SINK WAS CAUSING WATER TO POOL ON THE DECK BENEATH THE CLEAN DISH RACKS, EXPOSING ITEMS STORED ON THE LOWEST SHELF TO SPLASH.
Recommendation: Install a deflector inside the drain sink to ensure that wastewater is contained in the sink as the machine drains.
Item No.: 19
Site: Other-TERRACE CAFÉ - BUFFET
Violation: A SIDE SHIELD WAS MISSING ALONG THE PORT AND STARBOARD ENDS OF THE SERVICE LINE SNEEZE SHIELD AND ALSO IN THE CENTER LINE SECTION.
Recommendation: Install individual sneeze shields along the buffet service line where missing.
Item No.: 33
Site: Other-TERRACE CAFÉ - BUFFET
Violation: THE COVING ALONG ALL THE DECK TO WAITER STATION AND DECK TO FRONT BUFFET COUNTER JUNCTURES WAS NOT A MINIMUM 9.5 MM RADIUS.
Recommendation: Provide additional hard deck coving to reach a minimum 9.5 mm radius along the waiter station and front buffet counter junctures with the deck.
Item No.: 20
Site: Other-TERRACE CAFÉ - CHEESE CART
Violation: GORGONZOLA, BOURSIN, NECTARINE, MUNSTER, AND APANZOLA CHEESE BLOCKS WERE ON DISPLAY WITH NO INTERNAL REFRIGERATION SOURCE IN A CHEESE CART. THE INTERNAL TEMPERATURE OF THE CHEESES RANGED FROM 52-65 °F. THERE WAS NO WRITTEN PLAN IN PLACE DETAILING A TIME MANAGEMENT SYSTEM FOR THESE OR ANY OTHER POTENTIALLY HAZARDOUS FOODS.
Recommendation: 7.4.3.1.1 Equipment for cooling and heating food, and holding cold and hot food, shall be sufficient in number and capacity to maintain specified potentially hazardous food temperatures. If a time management system is being used for this or other foods a written plan should be available for review by the VSP during inspections.
Item No.: 30
Site: Other-TERRACE CAFÉ - GENERAL
Violation: HANDWASH STATIONS THROUGHOUT THE GALLEY, BUFFET, AND WAREWASH AREAS DID NOT HAVE SIGNS STATING 'WASH HANDS OFTEN'.
Recommendation: 7.7.1.1.7 A sign stating "WASH HANDS OFTEN" in a language that the food employees understand shall be posted over handwashing sinks.
Item No.: 06
Site: Other-POTABLE WATER
Violation: THE DAILY CALIBRATION OF THE BRIDGE ANALYZER/RECORDER WAS NOT DOCUMENTED ON THE CHART OR IN A SEPARATE LOG.
Recommendation: 5.5.1.2.1 The halogen analyzer-chart recorder shall be properly maintained, operated, and calibrated daily in accordance with the manufacturer's instructions. 5.5.1.2.2 The calibration shall be recorded on the chart or in a log book.
Item No.: 08
Site: Other-POTABLE WATER
Violation: THERE WAS NO COMPREHENSIVE CROSS-CONNECTION CONTROL PROGRAM IN PLACE.
Recommendation: 5.7.1.1.3 The vessel shall provide a comprehensive cross- connection control program that provides safe connections to the potable water system through air gaps or appropriate backflow devices at the following locations, if present: (1) Potable water supply lines to swimming pools, whirlpool spas, hot tubs, bathtubs, showers, and similar facilities; (2) Photographic laboratory developing machines and utility sinks; (3) Beauty and barber shop spray-rinse hoses; (4) Potable water faucets where hoses are connected or can be connected by threaded or quick-connect outlets such as those serving tanks containing chlorine and other chemicals, and deck taps; (5) Garbage grinders and pulpers; (6) Mechanical warewashing machines; (7) Hospital and laundry equipment; (8) Air conditioning expansion tanks; (9) Boiler feed water tanks; (10) Fire systems; (11) Toilets; (12) Potable water, bilge, and sanitary pumps that require priming; (13) Freshwater or saltwater ballast systems; (14) Bilge or other waste water locations; (15) International shore connection; and (16) Any other connection between potable and non-potable water systems.
Item No.: 40
Site: Other-INTEGRATED PEST MANAGEMENT (IPM)
Violation: THERE WERE NO RECORDS CERTIFYING THAT THE SECOND OFFICER WAS SUFFICIENTLY TRAINED TO APPLY RESTRICTED USE PESTICIDES.
Recommendation: 8.1.2.1.3 The training of the pest-control personnel shall be documented in the Integrated Pest Management Plan.
Item No.: 02
Site: Other-MEDICAL
Violation: THE STANDARDIZED GASTROINTESTINAL ILLNESS LOG ONBOARD DID NOT COVER ALL THE DATA ELEMENTS, INCLUDING CREW POSITION, LISTED IN THE VSP OPERATIONS MANUAL 2000.
Recommendation: 4.1.2.1.4 The gastrointestinal illness surveillance log entry for each passenger or crew member shall contain the following information: (1) The first date of clinic visit or report to staff of illness; (2) The person's name, age and gender; (3) A designation as passenger or crew member; (4) Crew member position or job on the vessel, if applicable; (5) Cabin number; (6) Meal seating information; (7) Date and time of illness onset; (8) Illness symptoms, including the presence of the following selected signs and symptoms: numbers of episodes each of diarrhea and vomiting per day, bloody stools, fever, recorded temperature; (9) Notation on whether or not a stool specimen was requested and received; (10) Use of antidiarrheal medication; and (11) The presence of underlying medical conditions which may affect interpretation of acute gastrointestinal illness for example diabetic diarrhea, inflammatory bowel disease, gastrectomy or others. 4.1.2.1.3 The log shall list: (1) All reportable cases of gastrointestinal illness; (2) All passengers and crew members who are dispensed antidiarrheal medication from the master of the vessel, the medical staff, or other designated staff.
Item No.: *
Site: Other-COMMENT
Violation: THE MANAGEMENT AND KNOWLEDGE DISPLAYED BY THE POTABLE WATER SYSTEM AND POOL/SPA SYSTEM STAFF WAS EXCELLENT.
Recommendation:
Item No.: 12
Site: Other-MAIN GALLEY - COLD PANTRY
Violation: WORKERS HANDLING READY-TO-EAT FOODS WERE OBSERVED WASHING THEIR GLOVED HANDS BETWEEN WORK WITH FOOD ITEMS.
Recommendation: Ensure that staff are aware of when gloves require changing and replacement and ensure they know that gloves are to be removed, hands washed, and new gloves donned when a glove change is required.
Item No.: 40
Site: Other-MAIN GALLEY - HOT GALLEY
Violation: THE DOOR TO THE GALLEY WAS OPEN TO A CORRIDOR AND THE CORRIDOR DOOR WAS OPEN TO THE OUTSIDE. NO INSECT BARRIER WAS PROVIDED.
Recommendation: 8.2.1.1.2 Entry points where pests may enter the food areas shall be protected.
Item No.: 20
Site: Other-MAIN GALLEY - HOT GALLEY
Violation: THE LARGE HAND-HELD BLENDER WAS NOT DESIGNED FOR EASY CLEANING. THE BLENDER HEAD COULD NOT BE DISASSEMBLED WITHOUT THE USE OF TOOLS.
Recommendation: 7.4.2.2.1 Multiuse food-contact surfaces shall be: (1) Smooth; (2) Free of breaks, open seams >1 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices; (4) Finished to have smooth welds and joints; and (5) Accessible for cleaning and inspection by one of the following methods without being disassembled, by disassembling without the use of tools, or by easy disassembling with the use of handheld tools commonly available to maintenance and cleaning personnel such as screwdrivers, pliers, open-end wrenches, and Allen wrenches.
Item No.: 26
Site: Other-MAIN GALLEY - POT WASH
Violation: THERE WAS A SMALL GRATER SOILED WITH FOOD RESIDUE STORED ON THE CLEAN STORAGE RACK.
Recommendation: 7.5.5.1.1 Food-contact surfaces of equipment and utensils shall be clean to sight and touch.
Item No.: 26
Site: Other-PREPARATION ROOM - POT WASH
Violation: NUMEROUS SOILED SHEET PANS WERE STORED AS CLEAN.
Recommendation: 7.5.5.1.1 Food-contact surfaces of equipment and utensils shall be clean to sight and touch.
Item No.: 16
Site: Other-PREPARATION ROOM - BUTCHER SHOP
Violation: THE SALMON USED FOR GRAVLAX WAS NOT CERTIFIED PARASITE FREE, NOR WAS IT FROZEN TO A SAFE TEMPERATURE AND TIME.
Recommendation: 7.3.4.2.1 Before service in ready-to-eat form, raw, raw-marinated, partially cooked, or marinated-partially cooked fish other than molluscan shellfish: (1) Shall be frozen throughout to a temperature of -20°C (-4°F) or below for 168 hours (7 days) in a freezer; or -35°C (-31°F) or below for 15 hours in a blast freezer.
Item No.: 22
Site: Other-FOOD SERVICE GENERAL
Violation: THE MOUNTED THERMOMETERS ON MOST OF THE FINAL SANITIZING RINSE SINKS ON THE 3 SINK ARRANGEMENTS WERE OUT OF CALIBRATION. THE CALIBRATION ERROR RANGED FROM 12-20 °F.
Recommendation: 7.5.2.1.1 Water temperature measuring devices: (1) That are scaled in Celsius or dually scaled in Celsius and Fahrenheit shall be designed to be accurate to ±1.5°C in the intended range of use. (2) That are scaled only in Fahrenheit shall designed to be accurate to ±3°F in the intended range of use.