Skip directly to site content Skip directly to page options

Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: Safari Quest Cruise Line: Un-Cruise Adventures Inspection Date: 05/26/2001 Inspection Score: 68
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 01
Site: Other-MEDICAL
Violation: A GASTROINTESTINAL ILLNESS SURVEILLANCE LOG WAS NOT MAINTAINED ON BOARD THE SHIP.
Recommendation: 4.1.2.1.1 A standardized gastrointestinal illness surveillance log for each cruise shall be maintained daily by the master of the vessel, the medical staff, or other designated staff. 4.1.2.1.2 The gastrointestinal illness surveillance log shall list the name of the vessel, the cruise dates and the cruise number. 4.1.2.1.3 The log shall list: (1) All reportable cases of gastrointestinal illness; (2) All passengers and crew members who are dispensed antidiarrheal medication from the master of the vessel, the medical staff, or other designated staff. 4.1.2.1.4 The gastrointestinal illness surveillance log entry for each passenger or crew member shall contain the following information: (1) The first date of clinic visit or report to staff of illness; (2) The person's name, age and gender; (3) A designation as passenger or crew member; (4) Crew member position or job on the vessel, if applicable; (5) Cabin number; (6) Meal seating information; (7) Date and time of illness onset; (8) Illness symptoms, including the presence of the following selected signs and symptoms: numbers of episodes each of diarrhea and vomiting per day, bloody stools, fever, recorded temperature; (9) Notation on whether or not a stool specimen was requested and received; (10) Use of antidiarrheal medication; and (11) The presence of underlying medical conditions which may affect interpretation of acute gastrointestinal illness for example diabetic diarrhea, inflammatory bowel disease, gastrectomy or others. 4.1.2.3.1 The medical log, gastrointestinal illness log, the daily inventory of antidiarrheal medication sales, and the 72 hour self-administered questionnaires shall be maintained on the vessel for 12 months.
Item No.: 03
Site: Other-POTABLE WATER
Violation: NO BUNKER CHLORINATION SYSTEM WAS AVAILABLE ON THE SHIP. WATER WAS NOT CHLORINATED TO AT LEAST 2 PPM.
Recommendation: 5.2.1.1.1 Potable water shall be continuously halogenated to at least 2.0 mg/L (ppm) free residual halogen at the time of bunkering or production with an automatic halogenation device.
Item No.: 06
Site: Other-POTABLE WATER
Violation: ITEMS 10,11, 12, FROM THE MAY 1, 2001 CONSTRUCTION REPORT WERE NOT COMPLETED. NO ANALYZERS, CHLORINE PUMPS, OR CHART RECORDERS WERE PROVIDED.
Recommendation: 5.4.1.1.1 All distribution water system halogenation devices shall be constructed and installed in accordance with recommended engineering practices.
Item No.: 08
Site: Other-POTABLE WATER
Violation: BACKFLOW DEVICES WERE NOT PROVIDED ON WATER LINES AS DESCRIBED IN 5.7 OF THE OPERATIONS MANUAL AND SECTION XX OF THE CONSTRUCTION MANUAL.
Recommendation: 5.7.1.2.1 Backflow preventers shall be installed when air gaps are impractical or when water under pressure is required. 5.7.1.1.3 The vessel shall provide a comprehensive cross- connection control program that provides safe connections to the potable water system through air gaps or appropriate backflow devices at the following locations, if present: (1) Potable water supply lines to swimming pools, whirlpool spas, hot tubs, bathtubs, showers, and similar facilities; (2) Photographic laboratory developing machines and utility sinks; (3) Beauty and barber shop spray-rinse hoses; (4) Potable water faucets where hoses are connected or can be connected by threaded or quick-connect outlets such as those serving tanks containing chlorine and other chemicals, and deck taps; (5) Garbage grinders and pulpers; (6) Mechanical warewashing machines; (7) Hospital and laundry equipment; (8) Air conditioning expansion tanks; (9) Boiler feed water tanks; (10) Fire systems; (11) Toilets; (12) Potable water, bilge, and sanitary pumps that require priming; (13) Freshwater or saltwater ballast systems; (14) Bilge or other waste water locations; (15) International shore connection; and (16) Any other connection between potable and non-potable water systems.
Item No.: 04
Site: Other-POTABLE WATER
Violation: CHLORINE LEVEL IN THE DISTRIBUTION SYSTEM WAS 0.09 PPM. WAS INCREASED TO 0.2 PPM DURING THE INSPECTION.
Recommendation: 5.4.1.2.1 The halogenation device shall provide continuous halogenation of the potable water distribution system and shall maintain a free residual halogen of 0.2 mg/L (ppm) and 5.0 mg/L (ppm) throughout the distribution system.
Item No.: 29
Site: Other-GALLEY
Violation: A DEDICATED HAND WASHING STATION WAS NOT PROVIDED.
Recommendation: 7.7.1.1.1 Each food preparation area, bar, warewashing area, and garbage-processing area shall have at least one handwashing facility located in it.
Item No.: 33
Site: Other-GALLEY
Violation: NON-EASILY CLEANABLE BULKHEADS AND DECKHEADS WERE NOTED IN THIS AREA. ITEM 19 OF THE MAY 1, 2001 CONSTRUCTION REPORT. ALSO, DECKING IN VARIOUS AREAS WAS NOT EASILY CLEANABLE.
Recommendation: 7.7.4.1.1 Decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas shall be constructed and maintained for easy cleaning.
Item No.: 19
Site: Other-AFT REFRIGERATION
Violation: RAW SHELL EGGS WERE STORED ABOVE READY TO EAT FOODS.
Recommendation: 7.3.3.2.1(1) Food shall be protected from cross-contamination by: (1) Physically separating raw animal foods during storage, preparation, holding, and display from raw ready-to-eat food including other raw animal food such as fish for sushi or molluscan shellfish, or other raw ready-to-eat food such as vegetables, and cooked ready-to-eat food; so products do not physically touch, and so as to prevent dripping of one product into another.
Item No.: 40
Site: Other-INTEGRATED PEST MANAGEMENT
Violation: A WRITTEN INTEGRATED PEST MANAGEMENT PLAN WAS NOT PROVIDED.
Recommendation: 8.1.1.1.1 Each vessel shall develop an Integrated Pest Management Plan to address effective monitoring and control strategies for pests aboard the vessel.
Item No.: 06
Site: Other-POTABLE WATER
Violation: A COPY OF A MICROBIOLOGICAL REPORT FROM EACH PORT WHERE WATER WAS BUNKERED WAS NOT AVAILABLE.
Recommendation: 5.1.1.2.1 Where available, the vessel shall have a copy of the most recent microbiologic report from each port before bunkering potable water to verify that the water meets potable standards.
Item No.: 08
Site: Other-POTABLE WATER
Violation: A SAMPLE POINT FOR TESTING THE CHLORINE IN THE BUNKERED WATER WAS NOT PROVIDED.
Recommendation: 5.2.1.2.7 Water samples for halogen testing shall be obtained from a sample cock located on the bunker or production water line at least 3 m (10 feet) after the halogen injection point and before the storage tank.
Item No.: 07
Site: Other-POTABLE WATER
Violation: POTABLE WATER TANKS WERE NOT INDEPENDENT FROM THE HULL OF THE SHIP.
Recommendation: 5.3.1.1.1 Potable water tanks shall not share a common wall with the hull of the vessel or with tanks containing non-potable water or other liquids.
Item No.: 03
Site: Other-POTABLE WATER
Violation: ENSURE THAT ITEMS 1 - 13 OF THE MAY 1, 2001 CONSTRUCTION INSPECTION ARE COMPLETED.
Recommendation:
Item No.: 10
Site: Other-WHIRPOOL SPA
Violation: ITEMS 14 - 16 FROM THE MAY 1, 2001 CONSTRUCTION INSPECTION WERE NOT COMPLETED.
Recommendation: A water filtration and halogenation system shall be provided.
Item No.: 07
Site: Other-GALLEY
Violation: ITEM 18 IN THE MAY 1,2001 CONSTRUCTION REPORT CONCERNING DRAIN LINE AIR BREAKS WAS NOT COMPLETED.
Recommendation: 7.7.3.1.1 Drain lines from all fixtures, sinks, appliances, compartments, refrigeration units, or devices that are used, designed for, or intended to be used in the preparation, processing, storage, or handling of food, ice, or drinks shall be indirectly connected to appropriate waste systems by means of an air-gap or air-break.
Item No.: 26
Site: Other-GALLEY
Violation: THE INTERIORS OF THE REACH-IN REFRIGERATOR AND FREEZER WERE SOILED.
Recommendation: 7.5.5.1.1 Food-contact surfaces of equipment and utensils shall be clean to sight and touch. Interiors of refrigerators are considered food contact surfaces.
Item No.: 27
Site: Other-GALLEY
Violation: THE INTERIORS OF SOME OF THE CABINETS WERE SOILED.
Recommendation: 7.5.5.1.3 Nonfood-contact surfaces of equipment shall be kept free of an accumulation of dust, dirt, food residue, and other debris.
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program