Skip directly to site content Skip directly to page options

Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: National Geographic Sea Bird Cruise Line: Lindblad Expeditions Inspection Date: 08/04/2001 Inspection Score: 97
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 21
Site: Other-GALLEY
Violation: THE INTERIOR OF THE GRILL/OVEN WAS NOT EASILY CLEANABLE.
Recommendation: 7.4.2.2.6 Nonfood-contact surfaces shall be free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 27
Site: Other-GALLEY
Violation: THE INTERIOR OF THE GRILL/OVEN WAS HEAVILY SOILED WITH FOOD AND GREASE RESIDUE.
Recommendation: 7.5.5.1.3 Nonfood-contact surfaces of equipment shall be kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 21
Site: Other-GALLEY
Violation: THERE WERE NON-EASILY CLEANABLE GAPS AROUND AND BETWEEN THE STOVE AND GRILL.
Recommendation: 7.4.2.2.6 Nonfood-contact surfaces shall be free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 27
Site: Other-GALLEY
Violation: THE GAP BETWEEN THE STOVE AND THE GRILL WAS SOILED WITH GREASE RESIDUE.
Recommendation: 7.5.5.1.3 Nonfood-contact surfaces of equipment shall be kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 27
Site: Other-GALLEY
Violation: THE UNDERCOUNTER CABINET NEXT TO THE SINK WAS SOILED.
Recommendation: 7.5.5.1.3 Nonfood-contact surfaces of equipment shall be kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 33
Site: Other-FOOD SERVICE-GENERAL
Violation: THERE WERE NON-EASILY CLEANABLE GAPS ON THE BULKHEADS AND DECKHEADS IN VARIOUS AREAS.
Recommendation: 7.7.4.1.1 Decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas shall be constructed and maintained for easy cleaning.
Item No.: 06
Site: Other-POTABLE WATER
Violation: A MINIMUM OF 4 WATER SAMPLES WERE NOT COLLECTED AND ANALYZED MONTHLY.
Recommendation: 5.6.1.1.1 A minimum of four potable water samples per month shall be collected and analyzed for the presence of Escherichia coli. Samples shall be collected randomly from locations forward, aft, upper, and lower decks of the vessel.
Item No.: 08
Site: Other-POTABLE WATER
Violation: A HALOGEN PH WAS NOT CONDUCTED ON THE SHORE SIDE WATER SUPPLY BEFORE BUNKERING.
Recommendation: 5.2.1.2.1 A halogen demand test and pH shall be conducted on the shore-side water supply before starting the bunkering process to establish the correct halogen dosage.
*Inspections scores of 85 or lower are NOT satisfactory