Skip directly to site content Skip directly to page options

Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: Crystal Symphony Cruise Line: Crystal Cruises LTD Inspection Date: 12/06/2001 Inspection Score: 95
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 40
Site: Other-INTEGRATED PEST MANAGEMENT
Violation: ALTHOUGH PHYSICAL PROCEDURES ARE IN PLACE A MANAGEMENT PLAN WAS NOT DEVELOPED FOR THIS VESSEL.
Recommendation: 8.1.1.1.1 Each vessel shall develop an Integrated Pest Management Plan to address effective monitoring and control strategies for pests aboard the vessel. 8.1.1.1.2 The Integrated Pest Management Plan shall set a schedule for periodic monitoring inspections including some at night. 8.1.1.1.3 The Integrated Pest Management Plan shall include provisions for active monitoring including pest sighting logs for the operational areas of the vessel and training for crew members in charge of log completion.
Item No.: 33
Site: Other-LIDO
Violation: INVERTED NIPPLE RECESS WERE NOT PROVIDED FOR THE DOOR LOCKING MECHANISMS.
Recommendation: Install inverted nipple recess pieces where open channels exist on the door frames.
Item No.: 33
Site: Other-LIDO
Violation: LOOSE SEALANT WAS NOTED AROUND THE BASE OF A DOOR FRAME.
Recommendation: 7.7.4.1.1 Decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas shall be constructed and maintained for easy cleaning.
Item No.: 41
Site: Other-CHILD ACTIVITY CENTER
Violation: THERE WAS NO HAND WASH SIGN BY THIS HAND WASH STATION.
Recommendation: 10.2.1.1.5 Signs shall be posted in children's toilet room advising the providers to wash their hands and the children's hands after assisting children use the toilet.
Item No.: 20
Site: Other-MAIN GALLEY
Violation: ALL REACH-IN COOLERS WERE NOT PROVIDED WITH FOOD TEMPERATURE MEASURING DEVICES
Recommendation: 7.4.2.4.9.1 Temperature measuring devices shall conform to the following guidelines: (1) In a mechanically refrigerated or hot-food storage unit, the sensor of a temperature measuring device shall be located to measure the air temperature in the warmest part of a mechanically refrigerated unit and in the coolest part of a hot-food storage unit.
Item No.: 16
Site: Other-MAIN GALLEY
Violation: SHELLED EGGS IN ICE BATH WERE RECORDED AT 51°F.
Recommendation: 7.3.5.3.1.1 Potentially hazardous food shall be maintained: (1) At 60°C (140°F) [roasts 54°C (130°F)] or above,; or (2) At 5°C (41°F) or less.
Item No.: 16
Site: Other-MAIN GALLEY
Violation: PANCAKE MIX STORED IN ICE BATH WAS RECORDED AT 74°F.
Recommendation: 7.3.5.3.1.1 Potentially hazardous food shall be maintained: (1) At 60°C (140°F) [roasts 54°C (130°F)] or above,; or (2) At 5°C (41°F) or less.
Item No.: 16
Site: Other-MAIN GALLEY
Violation: RAW STEAK FILLETS HELD IN AN ICE BATH WERE RECORDED AT 60°F.
Recommendation: 7.3.5.3.1.1 Potentially hazardous food shall be maintained: (1) At 60°C (140°F) [roasts 54°C (130°F)] or above,; or (2) At 5°C (41°F) or less.
Item No.: *
Site: Other-C.A.S.
Violation: IN DEVELOPING THE CORRECTIVE ACTION STATEMENT FOR THIS INSPECTION, CRITICAL-ITEM DEFICIENCIES (DESIGNATED WITH YES IN CRITICAL COLUMN (WORTH 3 - 5 POINTS), WHETHER DEBITED OR NOT, SHOULD INCLUDE STANDARD OPERATING PROCEDURES AND MONITORING PROCEDURES IMPLEMENTED TO PREVENT THE RECURRENCE OF THE CRITICAL DEFICIENCY. PREPARE CORRECTIVE ACTION STATEMENT AS A WORD PROCESSING OR SPREADSHEET FILE WHICH WILL BE SENT TO USPHS / VSP AS AN EMAIL MESSAGE ATTACHMENT. PLEASE EMAIL CORRECTIVE ACTION STATEMENT TO: VSP@CDC.GOV USE EMAIL MESSAGE SUBJECT LINE: SHIP NAME - CAS - [INSERT INSPECTION DATE] .
Recommendation:
*Inspections scores of 85 or lower are NOT satisfactory