Cruise Ship: Silver Whisper Cruise Line: Silversea Inspection Date: 11/29/2001 Inspection Score: 98
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 17
Site: Other-FOOD SERVICE GENERAL
Violation: GRAVLAX AND RAW SALMON WERE SERVED AND NO STATEMENT WAS PROVIDED BY THE SUPPLIER THAT THESE FISH WERE FROZEN TO A SAFE TEMPERATURE AND TIME TO KILL PARASITES.
Recommendation: 7.3.4.2.2 If raw, raw-marinated, partially cooked, or marinated-partially cooked fish are served in ready-to-eat form: (1) The person in charge shall record the freezing temperature and time to which the fish are subjected and shall retain the records on the vessel for 90 calendar days beyond the time of service or sale of the fish; or (2) If the fish are frozen by a supplier, a written agreement or statement from the supplier stipulating that the fish supplied are frozen to a safe temperature and a time (-20 °C(-4 °F) or below for 7 days in a freezer or -35 °C(-31 °F) or below for 15 hours in a blast freezer).
Item No.: 16
Site: Other-FOOD SERVICE GENERAL
Violation: THE LOG FOR THE BLAST CHILLERS IN THE MAIN AND CREW GALLEY REVEALED THAT THERE WAS NO TEMPERATURE CHECK FOR THE 2 HOUR OR 6 HOUR COOLING POINTS. SOME PRODUCTS WERE COOLED FOR OVER 8 HOURS WITH ONLY A TEMPERATURE RECORD AT THE START AND END TIMES.
Recommendation: 7.3.5.2.1 Cooked potentially hazardous food shall be cooled: (1) Within 2 hours, from 60°C (140°F) to 21°C (70°F); and (2) Within 4 hours, from 21°C (70°F) to 5°C (41°F) or less. Ensure that the log entries refer to these time periods.
Item No.: 28
Site: Other-MAIN GALLEY - POT WASH
Violation: A LARGE QUANTITY OF STANDING WATER WAS PRESENT DIRECTLY BENEATH THE CLEAN STORAGE RACK, SO AS STAFF WALKED BY WATER SPLASHED AND COULD CONTAMINATE INVERTED PANS AND POTS STORED ON THE LOWEST SHELF.
Recommendation: Recommend attempting the correction at the source of the water. In the interim period, suggest use of removable stainless steel splash shields on the lowest shelves of each rack.
Item No.: 22
Site: Other-MAIN GALLEY - POT WASH
Violation: THERE WAS NO MANUFACTURERS DATA PLATE ON THE LARGE POT WASH MACHINE.
Recommendation: 7.5.2.2.3 A warewashing machine shall be provided with an easily accessible and readable data plate affixed to the machine by the manufacturer that indicates the machine's design and operating specifications including the: (1) Temperatures required for washing, rinsing, and sanitizing; (2) Pressure required for the fresh water sanitizing rinse; and (3) Conveyor speed for conveyor machines or cycle time for stationary rack machines.
Item No.: 14
Site: Other-MAIN GALLEY - PERSONNEL
Violation: TWO CHEFS WHO WERE PREPARING FOODS WERE WEARING WRIST WATCHES.
Recommendation: 7.2.3.3.1 While preparing food, food employees may not wear jewelry on their arms and hands.
Item No.: 26
Site: Other-CREW MESS
Violation: SEVERAL PREVIOUSLY CLEANED GLASSES STORED ON THE SERVICE LINE HAD A SOAP FILM ON THE INTERNAL SURFACES,
Recommendation: 7.5.5.1.1 Food-contact surfaces of equipment and utensils shall be clean to sight and touch. 7.3.3.4.1 Food shall only contact surfaces of equipment and utensils that are cleaned and sanitized.
Item No.: 26
Site: Other-CREW GALLEY - POT WASH
Violation: A FEW PREVIOUSLY CLEANED POTS, PANS AND BINS WERE FOUND SOILED WITH FOOD RESIDUE ON THE CLEAN STORAGE RACK.
Recommendation: 7.3.3.4.1 Food shall only contact surfaces of equipment and utensils that are cleaned and sanitized.
Item No.: 24
Site: Other-CREW GALLEY - POT WASH
Violation: THE FINAL SANITIZING RINSE SINK HAD NO CHLORINE RESIDUAL DURING ACTIVE USE. THE WATER TEMPERATURE IN THE SANITIZING SINK WAS 176 °F, BUT THE MOUNTED SINK THERMOMETER REGISTERED ONLY 160 °F.
Recommendation: 7.5.6.2.2 A chemical sanitizer shall be used in accordance with the EPA-approved manufacturer's label use instructions at a minimum temperature of 24°C (75°F) with an exposure time of 7 seconds for a chlorine solution and 30 seconds for other chemical sanitizers. 7.5.6.2.3.1 The sanitizing solutions shall be used with the following concentrations: (1) A chlorine solution shall have a concentration between 50 mg/L (ppm) and 200 mg/L (ppm).
Item No.: 22
Site: Other-CREW GALLEY - POT WASH
Violation: THE SANITIZING SINK MOUNTED THERMOMETER REGISTERED 160 °F, WHILE THE ACTUAL WATER TEMPERATURE WAS 176 °F.
Recommendation: 7.5.2.1.1 Water temperature measuring devices: (1) That are scaled in Celsius or dually scaled in Celsius and Fahrenheit shall be designed to be accurate to ±1.5°C in the intended range of use. (2) That are scaled only in Fahrenheit shall designed to be accurate to ±3°F in the intended range of use.
Item No.: 10
Site: Other-POOLS AND SPAS
Violation: THERE WAS NO SHEPHERD'S HOOK AT THE POOL. THE SPA'S HAD DRAIN COVERS WHICH WERE NOT ANTI-VORTEX COVERS.
Recommendation: 6.4.1.2.1 Easy access shepherd's hook and approved floatation device shall be provided at a prominent location near each public swimming pool. 6.4.1.2.2 Anti-vortex drain covers shall be provided on swimming pools and whirlpool spas.
Item No.: 10
Site: Other-POOLS AND SPAS
Violation: THERE WAS NO WRITTEN FECAL ACCIDENT RESPONSE PLAN FOR THE POOLS OR SPAS.
Recommendation: 6.1.2.2.2 A fecal accident response procedure shall be documented and available for review during inspections.
Item No.: 06
Site: Other-POTABLE WATER - DISTRIBUTION
Violation: THE STAFF WAS USING A TOTAL CHLORINE TEST REAGENT IN THEIR CHLORINE TEST KIT FOR MEASURING FREE CHLORINE RESIDUALS ON BOTH DISTRIBUTION AND BUNKER CHLORINATION ANALYZERS.
Recommendation: Contact the test kit manufacturer to provide free chlorine powder pillows for measuring free chlorine residuals. Recommend also ordering the standard solutions for calibrating this test kit.
Item No.: 06
Site: Other-POTABLE WATER
Violation: THE DRINKING WATER SAMPLES COLLECTED FROM PORTS WHERE THE SHIP BUNKERED WATER AND THE RANDOM SAMPLES COLLECTED ONBOARD THE SHIP MONTHLY WERE ANALYZED WITH A KIT WHICH USES A METHOD NOT ACCEPTED IN STANDARD METHODS FOR THE EXAMINATION OF WATER AND WASTEWATER.
Recommendation: 5.6.1.1.2 Samples shall be analyzed utilizing a method accepted in Standard Methods for the Examination of Water and Wastewater. Information was provided on 3 such test kits during this inspection.
Item No.: 08
Site: Other-POTABLE WATER - PRODUCTION
Violation: THERE WAS NO RECORD OF FREE CHLORNIE RESIDUAL MONITORING AT LEAST ONCE EVERY 4 HOURS DURING ONBOARD PRODUCTION OF POTABLE WATER.
Recommendation: 5.2.1.2.2 Free residual halogen monitoring shall be performed at least hourly during the bunkering of potable water and performed at least once every 4 hours during the onboard production of potable water. 5.2.1.2.3 Accurate records of this monitoring shall be maintained aboard for 12 months and shall be available to the VSP for review during inspections.
Item No.: 40
Site: Other-INTEGRATED PEST MANAGEMENT (IPM)
Violation: THE EXISTING PLAN DESCRIBES WHAT CAN BE DONE TO CONTROL VARIOUS PESTS LISTED, BUT NOT WHAT IS ACTUALLY DONE FOR CONTROLLING THESE PESTS AND BY WHOM. THERE WAS NO RECORD OF THE TRAINING COMPLETED BY THE SHIP'S STAFF WHO PERFORM INSPECTIONS AND APPLY PESTICIDES. THERE IS NO MENTION OF THE RAT GUARDS IN USE, WHO ON THE SHIP INSPECTS INCOMING FOOD SHIPMENTS, AND WHAT THE CONTRACT PEST COMPANY DOES.
Recommendation: Provide additional information pages to your existing plan which details what is actually being done on the ship to control pests. List the pest which you are trying to exclude or control and explain what device or strategy is being used and who does the monitoring, inspections, and pest application. Provide the set schedule, including some inspections at night, and training records for all individuals who apply pesticides. Include training information and other details of the pest control contractors activities.
Item No.: *
Site: Other-COMMENT
Violation: GOOD TEMPERATURE CONTROL AND STORAGE PRACTICES WERE NOTED FOR POTENTIALLY HAZARDOUS FOODS. THE ORGANIZATION AND RECORDKEEPING BY THE MEDICAL STAFF WAS OUTSTANDING.
Recommendation:
Item No.: *
Site: Other-COMMENT
Violation: IN DEVELOPING THE CORRECTIVE ACTION STATEMENT FOR THIS INSPECTION, CRITICAL-ITEM DEFICIENCIES (DESIGNATED WITH YES IN CRITICAL COLUMN (WORTH 3 - 5 POINTS), WHETHER DEBITED OR NOT, SHOULD INCLUDE STANDARD OPERATING PROCEDURES AND MONITORING PROCEDURES IMPLEMENTED TO PREVENT THE RECURRENCE OF THE CRITICAL DEFICIENCY. PREPARE CORRECTIVE ACTION STATEMENT AS A WORD PROCESSING OR SPREADSHEET FILE WHICH WILL BE SENT TO USPHS / VSP AS AN EMAIL MESSAGE ATTACHMENT. PLEASE EMAIL CORRECTIVE ACTION STATEMENT TO: VSP@CDC.GOV USE EMAIL MESSAGE SUBJECT LINE: SHIP NAME - CAS - [INSERT INSPECTION DATE] .
Recommendation:
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program