Cruise Ship: Nippon Maru Cruise Line: Mitsui O.S.K. Passenger Line, Ltd Inspection Date: 04/09/2002 Inspection Score: 96
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 16
Site: Other-DINING ROOM
Violation: AT END OF SERVICE, CANTALOUPE AND WATERMELON CUBES WERE AT 8°C - 11°C ON BUFFET DISPLAY.
Recommendation: 7.3.5.3.1.1 Potentially hazardous food shall be maintained: (2) At 5°C (41°F) or less. 7.4.3.1.1 Equipment for cooling and heating food, and holding cold and hot food, shall be sufficient in number and capacity to maintain specified potentially hazardous food temperatures. If temperature is to be used as control, furhter recommend: Blast chilling product before bringing out to service line; using small metal containers that will transfer cold temperatures from ice better than current plastic containers; and submerging sides of container completely in ice or ice and water slurry to maximize available cooling potential. ---------------------------------------------------------------------------------------------------------------------------- If time is used as control: 7.3.5.3.5 If time only, rather than time in conjunction with temperature, is used as the public health control for a working supply of potentially hazardous food before cooking, or for ready-to-eat potentially hazardous food that is displayed or held for service for immediate consumption: (1) The food shall be marked or otherwise identified to indicate the time that is 4 hours past the point in time when the food is removed from temperature control; (2) The food shall be cooked and served, served if ready-to-eat, or discarded, within 4 hours from the time when the food is removed from temperature control; and (3) The food in unmarked containers or packages or marked to exceed a 4 hour limit shall be discarded. 7.3.5.3.6 Written procedures that ensure compliance with these guidelines shall be maintained on the vessel and made available to the VSP, upon request.
Item No.: 28
Site: Other-DINING ROOM
Violation: SILVERWARE FOR PASSENGERS WAS BEING DISPENSED IN UNCOVERED PLASTIC BASKETS.
Recommendation: 7.5.7.3.4 Eating utensils dispensed at a consumer self-service unit such as a buffet or salad bar shall be protected from contamination.
Item No.: 13
Site: Other-GALLEY - DISHWASHING
Violation: ENSURE MONITORING OF FINAL SANITIZING RINSE TEMPERATURE IS DONE CORRECTLY. UTENSIL SURFACE TEMPERATURE MEASUREMENT SHOULD BE DONE ONLY IN THE FINAL SANITIZING RINSE SPRAY. CURRENT METHOD INCLUDED RUNNING THERMOMETER THROUGH ENTIRE MACHINE WHERE THE HIGHER TEMPERATURES OF WASH AND RINSE WERE INFLUENCING THE MEASURED TEMPERATURE.
Recommendation: 7.2.1.2.1.9 The person in charge of the food operations on the vessel shall ensure that: (9) Employees are properly sanitizing cleaned multiuse equipment and utensils before they are reused, through routine monitoring of solution temperature and exposure time for hot water sanitizing, and chemical concentration, pH, temperature, and exposure time for chemical sanitizing. Consult VSP Operations Manual 2000, Annex 13.7, Warewashing Evaluation, for detailed procedures for effective monitoring.
Item No.: 26
Site: Other-GALLEY - DISHWASHING
Violation: PLASTIC BEVERAGE DISPENSER NOZZLES HAD NOT BEEN DISASSEMBLED FOR CLEANING AND WERE SOILED WITH OLD BEVERAGE RESIDUE.
Recommendation: 7.5.5.1.1 Food-contact surfaces of equipment and utensils shall be clean to sight and touch. Fully disassemble dispensing nozzle and brush clean parts and orifices.
Item No.: 20
Site: Other-GALLEY - DISHWASHING
Violation: LARGE CUTTING BOARD WAS SCORED AND SURFACE WAS BECOMING DIFFICULT TO CLEAN.
Recommendation: 7.4.2.2.1 Multiuse food-contact surfaces shall be: (1) Smooth; (2) Free of breaks, open seams >1 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections. 7.4.5.1.3 Surfaces such as cutting blocks and boards that are subject to scratching and scoring shall be resurfaced if they no longer can be effectively cleaned and sanitized, or discarded if they are not capable of being resurfaced. 7.4.5.2.1.1 Utensils shall be maintained in a state of repair or condition that meets the materials, design and construction specifications of these guidelines or shall be discarded.
Item No.: 21
Site: Other-GALLEY - HOT GALLEY
Violation: SEVERAL DRY CABINET LATCHING HANDLES WERE BECOMING LOOSE CREATING DIFFICULT TO CLEAN SEAMS WHERE THEY JOIN THE DOOR.
Recommendation: 7.4.2.2.6 Nonfood-contact surfaces shall be free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance. 7.4.5.1.2 Nonfood-contact equipment shall be maintained in good repair and proper adjustment including: (1) Equipment shall be maintained in a state of repair and condition that meets the materials, design, construction, and operation specifications of these guidelines. (2) Equipment components such as doors, seals, hinges, fasteners, and kick plates shall be kept intact, tight, and adjusted in accordance with manufacturer's specifications.
Item No.: 26
Site: Other-GALLEY - HOT GALLEY
Violation: LARGE WIRE WHISK HANGING IN CLEAN UTENSIL STORAGE NEAR KETTLES HAD FOOD SOIL ON IT.
Recommendation: 7.5.5.1.1 Food-contact surfaces of equipment and utensils shall be clean to sight and touch. Consider using automatic warewashing equipment as a final step to facilitate the detailed cleaning of food preparation utensils and equipment and to improve consistency.
Item No.: 21
Site: Other-GALLEY - HOT GALLEY
Violation: A DIFFICULT TO CLEAN GAP BETWEEN COOKING SURFACE AND ADJACENT COUNTER WAS NOTED ON RIGHT SIDE OF FLAT TOP GRILL.
Recommendation: 7.4.2.2.6 Nonfood-contact surfaces shall be free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 27
Site: Other-GALLEY - HOT GALLEY
Violation: SOME OLD FOOD SOIL WAS NOTED IN GAP ON RIGHT SIDE OF FLAT TOP GRILL.
Recommendation: 7.5.5.1.3 Nonfood-contact surfaces of equipment shall be kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 30
Site: Other-PROVISIONS - VEGETABLE PREP
Violation: A WASTE RECEPTACLE WAS NOT LOCATED AT HANDWASHING STATION.
Recommendation: 7.7.1.1.6 A handwashing facility shall include a sink, soap dispenser, single-use towels dispenser, and waste receptacle.
Item No.: 26
Site: Other-PROVISIONS - VEGETABLE PREP
Violation: FOOD SOIL WAS FOUND ON SEVERAL PLASTIC BINS ON THE CLEAN STORAGE SHELF.
Recommendation: 7.5.5.1.1 Food-contact surfaces of equipment and utensils shall be clean to sight and touch. Consider using automatic warewashing equipment as a final step to facilitate the detailed cleaning of food preparation utensils and equipment and to improve consistency.
Item No.: 33
Site: Other-PROVISIONS - COLD ROOMS
Violation: DIFFICULT TO CLEAN EXPOSED CABLING AND PIPING WERE NOTED IN ALL COLD ROOMS AND FREEZERS. TORN INSULATION WAS NOTED ON PIPING. MEAT FREEZER HAD A CONDENSATE LINE SPILLING ON SHELF AND DECK.
Recommendation: 7.7.4.1.1 Decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas shall be constructed and maintained for easy cleaning. 7.7.4.1.3 Bulkhead and deck junctures shall be coved. 7.7.4.1.4 Bulkheads and deckheads shall have smooth, hard finishes, and light colored surfaces. 7.7.4.1.6 Light fixtures, vent covers, and similar equipment attached to the bulkheads or deckheads shall be easily cleanable. 7.7.4.1.7 Exposed utility service lines and pipes, including lines for fire detection and protection systems, shall be installed so they do not obstruct or prevent cleaning. 7.7.4.2.3 Decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas, shall be maintained in good repair.
Item No.: 19
Site: Other-PROVISIONS - COLD ROOMS
Violation: DECORATIVE BLOCK ICE WAS NOTED STORED ADJACENT TO FOOD IN SEVERAL LOCATIONS IN FREEZERS.
Recommendation: 7.3.3.7.1 Food shall be protected from contamination that may result from a factor or source such as seawater, bilge water, or hydraulic or fuel lines.
Item No.: 21
Site: Other-GARBAGE ROOM
Violation: PAINTED WOODEN SHELVING WAS NOTED IN GARBAGE STORAGE COLD ROOM.
Recommendation: 7.4.2.1.2 Nonfood-contact surfaces of equipment and utensils shall be designed and constructed to be durable and to retain their characteristic qualities under normal use conditions.
Item No.: 33
Site: Other-CREW MESS - DISHWASHING
Violation: GROUT USED FOR CREATING SANITARY COVING FOR DECK / BULKHEAD SEAM HAS BEEN DAMAGED ALONG TOP EDGE CREATING A DIFFICULT TO CLEAN AREA.
Recommendation: 7.7.4.2.3 Decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas, shall be maintained in good repair.
Item No.: *
Site: Other-CORRECTIVE ACTION STATEMENT
Violation:
Recommendation: In developing the Corrective Action Statement for this inspection, critical-item deficiencies (designated with Yes in Critical Column (worth 3 - 5 points), whether debited or not, should include standard operating procedures and monitoring procedures implemented to prevent the recurrence of the critical deficiency. Prepare Corrective Action Statement as a word processing or spreadsheet file which will be sent to USPHS / VSP as an email message attachment. Please email Corrective Action Statement to: vsp@cdc.gov Use email message subject line: NIPPON MARU - CAS - 04-09-2002 .
Item No.: 03
Site: Other-POTABLE WATER
Violation: ENSURE THAT BUNKERED WATER IS CHLORINATED TO AT LEAST 2.0 PPM. RECORD THE CORRECT CHLORINE LEVEL HOURLY. RECOMMEND THAT SOMEONE FROM THE NIPPON MARU STAFF RESPONSIBLE FOR THE POTABLE WATER SYSTEM OPERATION AND MONITORING ATTEND THE VSP TRAINING SEMINAR FOR UPDATING THEIR KNOWLEDGE OF ALL OF THE NEW OPERATIONAL REQUIREMENTS.
Recommendation: 5.2.1.1.1 Potable water shall be continuously halogenated to at least 2.0 mg/L (ppm) free residual halogen at the time of bunkering or production with an automatic halogenation device.
Item No.: 22
Site: Other-BARS - GENERAL
Violation: THE SPRAY ARMS IN TWO OF THE GLASS WASHERS WERE NOT PROPERLY ALIGNED.
Recommendation: 7.5.4.1.1 Warewashing equipment shall be maintained in good repair and proper adjustment including: (1) Warewashing equipment shall be maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines. (2) Water pressure, and water temperature measuring devices shall be maintained in good repair and be accurate within the intended range of use.
Item No.: 33
Site: Other-POOL BAR
Violation: NON-EASILY EXPOSED PIPING AND WIRING WAS NOTED IN THIS AREA.
Recommendation: 7.7.4.1.1 Decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas shall be constructed and maintained for easy cleaning.